| 1 | Providing and fixing of solar power plant of following specifications suitable for 2 KWP at G+2 of BOP Chowkichar- |
| 2 | SOLAR PHOTO VOLTAIC MODULE ( SPV Module)Module Rating: 335 WP Module Type: Poly Crystalline ModuleMakes : Luminious/ TATA/USHA/UK Solar/Microtek |
| 3 | SOLAR BATTERY Nominal Voltage : 12 Volt. Nominal Capacity : 150 AH Battery Type: C10 Solar BatteryMake: USHA/Exide/ Luminious |
| 4 | SOLAR PCU Nominal Capacity: 2 KVA - 12/ 24 VoltMake: USHA/Microtek/Luminious |
| 5 | Battery enclosure PVC type with MS angle frame including lock & Key arrangement etc as required |
| 6 | Photo Voltic (PV) Module mounting 40 X 40 mm square type GI Structure complete, Minmum height of panel upper edge 2 mtr and lower edge 1 mtr from ground level etc as required |
| 7 | wiriring of panels for interconnection with DC cable of 1.5 KV, 4 sqmm of reputed make KEI/Havells/ Richa /Polycab/Anchor |
| 8 | AC cable 10 sqmm single core for connection of inverter to MCB DB box including connection etc as required make KEI/Havells/ Richa /Polycab/Anchor |
| 9 | Lightning Arrestor- 01 Mtr , 17.2 mm copper bondedetc as required |
| 10 | Chemical earthing with Earthing rod of size 02 Mtr long, 17.2 mm copper bonded etc as required |
| 11 | steel Cable tye 300 mm as required |
| 12 | Other BOS ( MMS class PVC conduit pipe, shaddle, nut bolt washer CC work etc as per site requirements) |
| 13 | Transportation charges from factory to site on IBB |
| 14 | Installation, testing and commissioning of 2 KWP solar power plant in G+2 tower etc as required |
| 15 | Providing and fixing of solar power plant of following specifications suitable for 1 KWP at ACP shelter of BOP Takkamari- |
| 16 | SOLAR PHOTO VOLTAIC MODULE ( SPV Module)Module Rating: 335 WP Module Type: Poly Crystalline ModuleMakes : Luminious/ TATA/USHA/UK Solar/Microtek |
| 17 | SOLAR BATTERY Nominal Voltage : 12 Volt. Nominal Capacity : 150 AH Battery Type: C10 Solar BatteryMake: USHA/Exide/ Luminious |
| 18 | SOLAR PCU Nominal Capacity: 1 KVA - 12/ 24 VoltMake: USHA/Microtek/Luminious |
| 19 | Battery enclosure PVC type with MS angle frame including lock & Key arrangement etc as required |
| 20 | Photo Voltic (PV) Module mounting 40 X 40 mm square type GI Structure complete, Minmum height of panel upper edge 2 mtr and lower edge 1 mtr from ground level etc as required |
| 21 | wiriring of panels for interconnection with DC cable of 1.5 KV, 4 sqmm of reputed make KEI/Havells/ Richa /Polycab/Anchor |
| 22 | AC cable 10 sqmm single core for cnnection of inverter to MCB DB box including connection etc as required make KEI/Havells/ Richa /Polycab/Anchor |
| 23 | Lightning Arrestor- 01 Mtr , 17.2 mm copper bondedetc as required |
| 24 | Chemical earthing with Earthing rod of size 02 Mtr long, 17.2 mm copper bonded etc as required |
| 25 | steel Cable tye 300 mm as required |
| 26 | Other BOS ( MMS class PVC conduit pipe, shaddle, nut bolt washer CC work etc as per site requirements) |
| 27 | Transportation charges from factory to site on IBB |
| 28 | Installation, testing and commissioning of 1 KWP solar power plant in ACP tower etc as required |