Tender For Construction Work Of Night Shelter At Village Council Korya Durga Temple - Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil (D.S.R 2.6.1) 2 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). (D.S.R 4.1.8) 3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (D.S.R.5.1.2) 4 Same as above in item No 3 but for Slabs and Cantilever slabs as per Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (D.S.R.5.3) 5 Same as above in item No 3 but for Column as per 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)(D.S.R.5.2.2) 6 Thermo-Mechanically Treated bars of grade Fe-500D or more. (D.S.R.5.22.6) 7 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (D.S.R.6.1.2) 8 Same as above in item No 7 but in super structure for wall of one brick thickness Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure above plinth level.Cement mortar 1:6 (1 cement : 6 coarse sand)(D.S.R.6.4.2) 9 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)(D.S.R.6.13.2) 10 12 mm thick plaster with 1:6 cement and coarse sand morter on brick work including ranking and joint washing and cleaning and including supply of allmaterials labour and T&P etc. required for proper completion of work. (D.S.R.13.4.2) 11 Same as above in item No 12 but for plaster on rough face .(D.S.R.13.5.2) 12 Steel work In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete(D.S.R.10.25.1) 13 Providing and fixing with putty and navls whereever necessary including aleat glass panes 4 mm thickness D.S.R.14.5.1 14 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (D.S.R.9.21)35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (D.S.R.9.21.1) 15 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.(D.S.R.2.25) 16 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete.(D.S.R.2.27) 17 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm As per (D.S.R 11.41.2) 18 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (D.S.R.13.47.1) 19 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (D.S.R.13.41.1) 20 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.13.48.2) 21 Supply and fixing of sign board including supply and cost of all material, labour T&P required templet as directed by the Engineer Incharge. 22 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(D.S.R.1.3.3) 23 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(D.S.R.1.5)Power plug wiring in PVC conduit ( 4x4 sqmm ) DSR NO.1.12 24 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(D.S.R.1.14.1) 25 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(D.S.R.1.14.2) 26 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. As required5/6 A Switch DSR NO.1.24.1 27 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. As required15/16 A Switch DSR NO.1.24.3 28 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. As required DSR NO.1.25 29 Installation, testing and commissioning of ceiling fan , including wiring the down rods of standard lrnght ( upto 30 cm ) with 1.5 sq mm FRLS PVC insulated, copper conductor , single core cable , including providing and fixing phenolic laminated sheet cover on the fan box etc. As required DSR NO. 1.25 30 Supplying and fixing offollowing ways surface / recess mounting , vertical type,415 V , TPNMCB distribution board of sheet steel, dust protected, duly powder painted,inclusive of 200 A Tinned copper busbar for mounting MCBs (but without MCBs and incomer ) As required . ( Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way ( 4+12) , Double door.DSR NO. 2.5.1 31 Supply and Ceiling fan with fan motor of AC permanrnt insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comly with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volt 50 Hz , 1-ph AC The fan assemble should consist of down rod blades , shackle conopies etc. and with double ball breaing system.DSR NO.19.1 32 SANITARY WORK 33 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(D.S.R.17.1.1) 34 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20 mm dia nominal bore(D.S.R.18.10.2) 35 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 25 mm dia nominal bore(D.S.R.18.10.3) 36 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore(D.S.R.18.11.1) 37 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore(D.S.R.18.49.1) 38 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore(D.S.R.18.16.1) 39 GST @ 18%