| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP-B |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. i) 3 x 1.5 sqmm |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. ii) 6 x 1.5 Sqmm |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. iii) 3 x 4.0 sqmm |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. iv)6 x 4.0 Sqmm |
| 6 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i) 5/6 amps switch |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ii) 3 pin 5/6 A socket outlet |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 11 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 12 | Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V, 300 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required. |
| 13 | Supplying and fixing of 250 mm sweep, 1250-1300 RPM non metallic exhaust fan suitable for single phase, 50 Hz, 230 volt AC supply in existing opening including connection etc as required. of make Orient (ventilator dx) or equivalent make of Havells/Bajaj/CG. |
| 14 | Supply, installation, testing and commissioning of 20 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 15 | Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. |
| 16 | Supplying and fixing of following way single pole and neutral, sheet steel MCB distribution board 240 V on surface / in recess complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections powder painted including earthing etc as required (But without/MCB/RCCB/ISOLATOR). i) 12 way double door |
| 17 | Supplying and fixing 5 A to 32 A rating 240/415 volts,\"C\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Single pole |
| 18 | Supplying and fixing 5 A to 32 A rating 240/415 volts,\"C\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. ii) Double pole MCB |