| 1 | SH-I (Comprehensive Maintenance of DG set)Annual Preventive & Comprehensive / Periodical Maintenance Of following Cummins make D.G. Sets installed at following locations alongwith engine, alternator, AMF panel, batteries, pipeline and other associated accessories etc. complete with routine testing etc. as reqird and attending all major/minor faults or failure or complaint complete in all respect & providing at least one Electrical & Mechanical visit in a month as required, as per terms & condition attached and as per direction of Engineer-In-Charge a) 250 KVA capacity DG Set (ESN 25280794)- AUD |
| 2 | b) 250 KVA Capacity DG (ESN 25758144/25758145 - 2 Nos) |
| 3 | c) 125 KVA capacity DG Set |
| 4 | B-Check maintenance of following capacity Cummins make DG Sets including replacement of element assembly, element lub oil filter, check kit 6 CTA, Kit fuel filter and ring, kit super bypass, filter element, inhibitor, corrosion, air cleaner element, seal O-ring, Gasket, rocker, valve cover, strip test, lubricant oil etc. complete as required. a) 250 KVA capacity DG Set (ESN 25280794) - AUD |
| 5 | b) 250 KVA Capacity DG (ESN 25758144/25758145 - 2 Nos) |
| 6 | c) 125 KVA capacity DG Set |
| 7 | SH-II Routine Operation & MaintenanceRunning maintenance & operation, general upkeep, preventive maintenance including minor repair works, as and when required and recording reading in log book for 11 KV/440 Volts electrical substation comprising of transformer, HT/LT Panel, ACB, MCCB & allied accessories & keeping the entire installation on functional mode including D.G. set comprising of A.M.F. Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works by deploying staffs (wireman//E&M Operator- 3 Nos. round the clock, Khallasi - 1 No. general shift on all working day including Sunday and holiday) as per details and terms & conditions attached etc. as required. |
| 8 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the departmentto the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying staffs as per details and terms & conditions attached etc. as required. (wireman//E&M Operator- 3 Nos. round the clock, Khallasi - 3 Nos. round the clock on all working day including Sunday and holiday) |
| 9 | Providing services of Supervisor having experienced in electrical & mechanical works as per details deploying staff Supervisor- 1No. In general shift on all days of the month including Sunday & Holiday and as per Engineer-in-charge and terms & conditions attacted etc. complete as required. |
| 10 | Comprehensive maintenance of PA System which includes system management with inbuilt 5 zone selector amplifier, mics, 175 Nos Double cone type wall mounted speakers, mixer and its associated wiring alongwith other allied accessories etc installed in Krishna and Kaveri Hostel each at IGDTUW, Kashmere Gate including replacement of damaged and defective spare parts and minor repairs in case of any type of fault as per terms and conditions attached and as per direction of Engineer in charge etc as required. |
| 11 | SH-II - Repair/Replacement/Servicing of Electrical InstallationsWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(a) Group C |
| 12 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(a) Group C |
| 13 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 14 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 15 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 16 | (d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 18 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3 x 1.5 sq. Mm |
| 20 | (b) 3 x 4 sq. Mm |
| 21 | (c) 3 x 6 sq. Mm |
| 22 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a) 12 Module (200 mmX150 mm) |
| 23 | (b) 8 Module (125 mmX125 mm) |
| 24 | (c) 6 Module (200 mmX75 mm) |
| 25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 A switch |
| 26 | (b) 3 pin 5/6 A socket outlet |
| 27 | (c) 15/16 A switch |
| 28 | (d) 6 pin 15/16 A socket outlet |
| 29 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(a) 5/6 A switch |
| 30 | (b) 3 pin 5/6 A socket outlet |
| 31 | (c) 15/16 A switch |
| 32 | (d) 6 pin 15/16 A socket outlet |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 8 way, Double door |
| 34 | (b) 12 way , Double door |
| 35 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 8 way (4 + 24), Double door |
| 36 | (b) 12 way (4 + 36), Double door |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single Pole |
| 38 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 39 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(a) 100 A, 16 kA,TPMCCB |
| 40 | (b) 250 A, 35 kA,TPMCCB |
| 41 | (c) 400 A, 35 kA,TPMCCB |
| 42 | Earthing with G.I. earth pipe 4.5 meters long, 40 mm diameter including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 43 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 44 | Providing and fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 45 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.24.01) 20 mm |
| 46 | 24.02) 25 mm |
| 47 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 48 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 49 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 50 | Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.28.01) 1200mm, BEE 3 star rating, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum) |
| 51 | Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required. |
| 52 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. |
| 53 | Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable sizemakinggood the same i/c connections, interconnections etc. complete as reqd. |
| 54 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light, powder coated die cast aluminium /polycarbonate body with built in driver ( < 750ma),Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required\" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy system lumen efficacy ≥105 and <120 lm/Watt output. All as per pre approved by Engineer-in-charge32.01) 18-20watt (1200 mm 4 Feet) |
| 55 | Supplying, installation, testing & commissioning of 15 watt recess/surface mounted glarefree round LED downlight, system lumen efficancy 90Lm/W, cool day light (5700K to 6500K), power factor>0.90, CRI>80, LED lamp complete with all accessories, testing & commissioning etc. as required. |
| 56 | Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size)suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with thehelp of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 34W to 36W, LED lumen should be ≥ 3600 system efficacy of ≥ 110 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison. |
| 57 | Supplying, installation, testing & commissioning of energy efficient LED flood light luminaries of system wattages 200 watt complete with mounting brackets and accessories on the street light pole with help of tower wagon including connections complete as required. The LED luminaries should confirm the following technical specifications:-a) Type of LED: High power LEDs Nichia / Osram / Cree / Philipsb) driver efficiency >85%c) System Efficacy >120 lm/wd) color Index(CRI) Ra>70e) Color Temperature (CCT) Cool white: 4000°Kf) Input Voltage. 140-270V ACg) Frequency Range 50-60Hzh) Power Factor(PF) > 0.95i) Surge protection = 10KVj) Total Harmonic Distortion(THD)< 10%k) Working Environment 0°C to 50°C;10%-90%RH l) Working lifetime: >50000 hrs.m) IP Rating :- IP66n) Housing and finish:-epoxy powder coated die cast aluminum housing with elegantly designed heat sink for efficient thermal management and to excellent corrosion resistant, cable gland P49 is provided at cable entry cover & high quality toughned glass. |
| 58 | Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3.5 X 50 Sq.mm |
| 59 | b) 3 X 16 Sq.mm |
| 60 | c) 3.5 X 25 Sq.mm |
| 61 | d) 3.5 X 35 Sq.mm |
| 62 | e) 3.5 X 95 Sq.mm |
| 63 | f) 3.5 X 120 Sq.mm |
| 64 | g) 4 x 25 sq.mm |
| 65 | Supplying, installation, testing & commissioning of powder fire extinguisher (stored pressure type) capacity 6 Kg. (duly ISI marked) confirming to IS: 15683:2006 with IS: 14609, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operating manual and bracket, operating temperature 10ºC to +55ºC complete etc. as required. |
| 66 | Supplying, installation, testing & commissioning of CO2 type fire extinguisher (Duly ISI marked) confirming to IS: 15683 capacity 4.5 Kg. complete with delivery hose horn, squeeze grip/ wheel type release valve, locking arrangement, operation manual and bracket, operating temperature 30ºC to +55ºC complete etc. as required. |
| 67 | Less credit of following electrical accessories etc. complete as required.(a) Assorted copper wire/cable/pipe |
| 68 | (b) Scrap iron/ conduit/ box |
| 69 | (c) DBs (assorted size) |
| 70 | (d) MCBs (assorted size) |
| 71 | (e) MCCBs (assorted size) |
| 72 | (f) Switch/Socket (assorted size) |
| 73 | (g) Ceiling Fans assorted size |
| 74 | (h) Wall Fan (assorted size) |
| 75 | (i) Exhaust Fan (assorted size) |
| 76 | (j) Fresh Air Fan (assorted size) |
| 77 | (k) Batten Lights (assorted size) |
| 78 | (l) Downlights (assorted size) |
| 79 | (m) Flood Lights (assorted size) |
| 80 | (n) Cubical Panel with accessorires (assorted size) |
| 81 | (o) Assorted XLPE aluminium cable |