Tender For Construction Of Additional Building In Phc At Komal Panchayat In Kuthalam Block

Issued by Local Bodies · kuthalam, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Mar 2025
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kuthalam → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Construction Of Additional Building In Phc At Komal Panchayat In Kuthalam Block

BOQ

Name of Work : 01.Construction of Additional Building in PHC @ KomalPanchayat in Kuthalam Block
Sl. No. Item Description
1Construction of Additional Building in PHC @ KomalPanchayat in Kuthalam Block
2Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. Refilling the sides of foundation with excavated earth other than sand in layers of well rammed and compacted and depositing the surplus earth in places shown by the departmental officers with an initial lead of 10m and initial lift of 2m and clearing and leveling the site etc.complete complying with standard specification.
3Supplying and filling in foundation, basement, etc with filling M- sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
4Plain Cement Concrete: 1:4:8 - One part Cement:Four part Sand:Eight part hard broken stone jelly using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick,well rammed,consolidated and curing etc.complete complying with standar specification.
5Refilling the approved good quality earth in plinths, area development etc.wherever specifiedin layers is not exceeding 200 mm thick., with available earth at site.
6Supplying and filling of good earth filling locally available earth transported from the outside including consolidation,leveling specifiedin layers of not exceeding 200 mm thick., etc. complete.
7Supplying and Erecting Steel Centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
8Upto Basement
9Ground Floor
10Providing and laying in position machine batched, machine mixed and machine vibrated design mix Cement Concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1m3
11Foundation & Basement
12Ground Floor
13Supply,Fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes decoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings,specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position, chairs, pins, spacer bars unauthorised laps which will not be measured separately neither for payment nor for reconciliation and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover, and as directed.
14Brick work in following Cement Mortar 1:5 using best quality II class table moulded chamber burnt bricks of size 9\" x 4-3/8\" x 2-3/4\" for foundation and basement including curing etc.,complete complying with standard specification.including scaffolding curing cost of reinforcement etc.all complete as per specifications and drawings as directed by the Engineer in-charge.
15Foundation Basement Brick Work
16Ground Floor super structure
17Brick partition walls of 11.50cm thickness using best quality II class table moulded bricks 9\"x4-3/8\"x2-3/4\" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc.complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately).
18GroundFloor
19PLASTERING WORK
20Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of Sand ), to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams, and Sun shades etc.to correct plane and level including scaffolding, hacking of surface, chiselling the undulated surface wherever necessary and curing etc., all materials and labour complete in all respects including all lead, lift and descent and as directed by the Enineer in charge. This rate includes the cost of providing Cement Mortar beadings for sun shades, steps,landing slabs, elevation etc. complete complying with standard specifications.
21Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and Externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed.
22Flooring & Dadooing
23Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M.Sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
24Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic cost-Rs.464/sq.m
25Dadooing the walls with colouredDadooing Ceramic tiles of size 150mm x 150mm x 6mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surfacein all floors at the rate of 0.40 Kg /Sqm etc. complete.
26Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).
27Providing, fabricating and fixing M.S. grillsWindows,and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including
28S.S Handrail
29Supplying and fixing in position of G.I. Pipe Hand Rails 40mm
30Supply and Fabrication of UPVC doorincluding cost and conveyance of all charges etc complete.
31Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
32UPVC Windowsupplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sectionwith wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plainglass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and shouldhave key lockable action, security protective hinges, strong lockingsystems and as per sizefor arrestingnoise and energy loss.
33UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free , the profile are multi chambered sections withwall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work.
34PAINTING WORK
35Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications.
36Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
37Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
38Weathering Course Concrete using best quality broken brick jellyof 20 mm uniform guage in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jaggery water etc. complete complying with standard specifications and as directed
39Finishing the top of roof with one course of Machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
40Sub Estimate For PLUMBING
41PART - A SANITARY FITTNGS
42Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with crushed stone M.Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone M.Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works).
43Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofwhite coloured vitreous china under counterRegular rectangular wash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors- toilets. Wash Basin
44Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
45Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks).
46Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D)
47PART- B SOIL AND WASTE PIPES
48PVC Soil / Waste Pipes
49Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level.
50a).40mm dia. 6kg class PVC pipes.
51b).50mm dia. 6kg class PVC pipes.
52c).75mm dia. 6kg class PVC pipes.
53d)110mm dia. 6kg class PVC pipes.
54Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved a) 110mm dia. 4kg class pipes.
55PART-C - EXTERNAL DRAINAGE Soil/ Waste Pipes
56Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings,including all types of excavation, occur for pipe,filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2\"height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing.
57Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid ofcapacity of 1000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work)(TWAD- Pano:173)
58Sub Estimate For -ELECTRICAL
59Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )
60Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
61Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End
62Supply and fixing of fancy glass shade and 7W / 9W LED bulb
63Supply and fixing of single box type 4\"40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting
64Supply and fixing of 1200mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down
65Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
66Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
67Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug)
68Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2\" x 1-1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection with earth connection complete
69Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only
70Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing
71Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection
72Provision for geotechnical investigation report & DPR
73Provision for Quality Control Charges
74Name board and Photographic charges
75GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package} 12% for other than Earth Quantity

AI Tender Summary

OUR REF NO 48028969
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 05-03-2025
Authority
Authority Name Rural Development And Panchayats Department
Work Description Construction Of Additional Building In Phc At Komal Panchayat In Kuthalam Block
Basic Detail
Tender No 0373/2025/A2 Date 19.02.25
Bidding Type Tender
Location
City kuthalam
State Tamil Nadu
Key Dates
Publish Date 03 Mar 2025
Submission Date 05 Mar 2025
Open Date 05 Mar 2025
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 30000
Exemption Available
Document List
Tendernotice_1.pdf
bfc422e1-df61-4318-8b3c-36d45dd6b905.html
BOQ_630154.xls
Pricebid.pdf
Technicalbid.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 03, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 05, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 05, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

bfc422e1-df61-4318-8b3c-36d45dd6b905.html

xls

BOQ_630154.xls

pdf

Pricebid.pdf

pdf

Technicalbid.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders