Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed. |
| 3 | Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed. |
| 4 | M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 6 | Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 7 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 10 Sqmm, 4 core, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. |
| 8 | Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable withstranded aluminumconductor 1100 volt grade of size 16 Sqmm 4 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed including taking down old unserviceable XLPE cable with brick protection andcomplete all as specified and as directed. |
| 9 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 25 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 10 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 35 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 11 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 50 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 12 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 13 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 95 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 14 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 120 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 15 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 185 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 16 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 240 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 17 | Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured,3.5 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 400 Sqmm,stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 18 | Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed.Note : Cost of accessories required for making hole/bore deemed to be included in the quoted rate. |
| 19 | M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed. |
| 20 | M&L for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor / road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed. |
| 21 | M&L for 100 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor / road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed. |
| 22 | Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, hot shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 6 Sqmm to 16 Sqmm 2/3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. |
| 23 | Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, hot shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 25 Sqmm to 70 Sqmm 2/3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. |
| 24 | Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, hot shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 95 Sqmm to 185 Sqmm 2/3.5/4 Core complete all as specified and as directed.Note : Excavation and earth work shall be measured and paid separately. |
| 25 | Supply, jointing and testing XLPE cable end termination joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 35 Sqmm to 95 Sqmm 4 core complete all as specified and asdirected. |
| 26 | Supply, jointing and testing XLPE cable end termination joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 120 Sqmm to 240 Sqmm 4 core complete all as specified and asdirected. |
| 27 | S&F for precast RCC cable route indicator with embrossing mark as \"HT /LT CABLE \"duly painted with approved colour of size 75cm x 15cm x 7.5cm all as specifed and directed by Engr-in-Charge. |
| 28 | Dismantling /uprootingof LT unserviceable RCC poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition ofconcrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed.Note:- Earth work for taking out poles shall be measured and paid separately under relevant item of this Schedule. |
| 29 | Dismantling/uprootingof LT unserviceable steel poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition ofconcrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed.Note:- Earth work for taking out poles shall be deemed to quoted rate. |
| 30 | M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paintover a coat of primer except the planting depth which shall be painted withblack bituminous paintincluding writing pole number using suitable paintcomplete all as specified and as directed.Note : Excavation and Earth work, PCC fillingshall be measured and paid separately. |
| 31 | M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in pole foundation complete all as specified and as directed. |
| 32 | M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed. |
| 33 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of pole including necessary form work for fair finish surfaces complete all as specified and as directed |
| 34 | Dismantling LT stay assembly, of any size andremoving from the site(s) complete all as specified and as directed. |
| 35 | M&L for stay assembly comprising of 7/8 SWG galvanised stay of standard wire of reqd length fixed to pole with and including galvanised flat iron clamps, bolts, nuts and washers etc including galvanised steel 14 mm dia, 400 mm long stay bow and GI stay plate of size 300 x 300 x 6 mm thick, thimble MS clamp made out of 50 x 6mm and loop insulators porcelain brown all as shown in EP No.1 of SSR part - I including all accessories and excavation, earth work and PCC work complete all as specified and as directed. |
| 36 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and stackingaside serviceable materials for re-use with in 50m and removing unserviceable materials from site of workcomplete all as specified and as directed. |
| 37 | M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed. |
| 38 | Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed. |
| 39 | M&L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 150 mm height 150mm dia suitable for 1100 volts grade complete all as specified and as directed. |
| 40 | M&L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and as directed. |
| 41 | Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed. |
| 42 | Supply, fixing and stringing of aluminium conductor steel reinforced (ACSR) conductor of size (a) Squireel 6/1 x 2.11, (b) Weasel 6/1 x 2.59, (c) Rabbit 6/1 x 3.25 as suitable conforming to IS - 398 part- 4 of 1994 including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and as directed. |
| 43 | Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of any size and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed.Note : 04 Nos of ACSR or AAAC conductor shall be measured as one unit length. |
| 44 | S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 2 conductor, in spanwithout damaging the over head line including taking down old separator complete all as specified and as directed . |
| 45 | S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 4 conductor, in spanwithout damaging the over head line including taking down old separator complete all as specified and as directed . |
| 46 | S&F in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor, stranded of size 10 Sqmm x 2 core,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed. |
| 47 | S&F in repairs 1100 volts grade, heavy duty, cable PVC insulated, aluminium conductor, stranded of size 6 Sqmm x 2 core,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed. |
| 48 | S&F for PVC conduit pipe 20mm dia with fixing arrangement with flat iron with nut bolts on pole complete all as specified and as directed. |
| 49 | S&F in repairs non transparent SMC kiosks pole box 3/4 wirejunction box made engineering plastic one piece mouldingof size 310 x 210 x 120mm with connector bus bar 4 strips mounting on DMC unbrakable insulator with kitkat 20 A MCBcomplete fixedto street light pole with suitable sizeofmild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed. |
| 50 | S&F in repairs non transparent SMC kiosks pole box 2 wirejunction box made engineering plastic one piece mouldingof size 200 x 150 x 100mm with connector bus bar 2 strips mounting on DMC unbrakable insulator with kitkat 20 A MCBcomplete fixedto street light pole with suitable sizeofmild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed. |
| 51 | S&F in replacement of synthetic insulating mat of size 2.0mx1.0mx19mm at substations and other installations complete all as specified and as directed. |
| 52 | M&L for making of name board with 6mm thick PVC board and with mentioning letters of size not more than 50mm size (sticker type computer letters) all as specified and as directed for switch boards duly fixed to the wall with suitable fixing arrangements etc complete all as specified and as directed. |
| 53 | M&L for making danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 20 x 15 cm size including dismantling of old one complete all as specified and as directed. |
| 54 | M&L for preparation of old painted surface and removing dust and other deposited material by scraping from LT PSC/steel tubular poles of upto 11.00 metre long, cross arms brackets and applying two coats of aluminium paint to all steel surfaces, including MS clamps, cable protection pipe, bracket fitted with street light fittings etc and one coat of cement based paint to PSC pole including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed. Note : Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer. |
| 55 | Supply installation, testing and commissioning LT panel out door of size of size 0.60mx 0.60 mx 0.60 m with latest IP factory made totally enclosed dust and vermin proof, double steel steel shutter infront and single leaf shutter in rear side made of 3.15mm thick sheet duly fabricated and having proper locking arrangment in both front and rear door painted with powder coated paint and copper bus bar of 200 amps suitable for 500 volts, 50 Hzs, 3phase 4 wire system and comprising with and including following accessories and mounted on PCC platformall around the panel boardcomplete with the following items - Note: foundation to be included in the quoted price. INCOMING - : (a) Phase indicator lamps (RYB) -set of 3.(b) copper bus bar 4 strip- 200Amps (length should not be less than 0.6M)(c) Internal connection by Coppper strip from MCB/MCCB to bus bar and bus bar to MCB/MCCB etc. |
| 56 | Supply installation, testing and commissioning LT panel out door of size of size 0.60mx 0.60 mx 0.60 m with IP 54 factory made totally enclosed dust and vermin proof, double steelshutter infront and single leaf shutter in rear side made of 3.15mm thick sheet duly fabricated and having proper locking arrangment in both front and rear door painted with powder coated paint and copper bus bar of 200 amps suitable for 500 volts, 50 Hzs, 3phase 4 wire system and comprising with and including following accessories and mounted on PCC platform all around the panel boardcomplete with the following items - Note: foundation to be included in the quoted price. INCOMING - MCCB, 4pole, 100Amps, 25KA -01 No.(a) Phase indicator lamps (RYB) -set of 3.(b) copper bus bar 4 dtrip- 200Amps (length should not be less than 0.7M)(c) Internal connection by Coppper strip from MCB/MCCB to bus bar and bus bar to MCB/MCCB etc. |
| 57 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 400 Amps of breaking capacity 36 KA complete all as specified and as directed. |
| 58 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 630 Amps of breaking capacity 36 KA complete all as specified and as directed. |
| 59 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 250 Amps of breaking capacity 25 KA complete all as specified and as directed. |
| 60 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 200 Amps of breaking capacity 25 KA complete all as specified and as directed. |
| 61 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 160 Amps of breaking capacity 25 KA complete all as specified and as directed. |
| 62 | S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 125 Amps of breaking capacity 25 KA complete all as specified and as directed. |
| 63 | M&L On load change over switch 400 A with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed. |
| 64 | M&L Off load change over switch 400 A with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed. |
| 65 | M&L Off load change over switch 100 A with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed. |
| 66 | M&L Off load change over switch 63 A with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed. |
| 67 | M&L for preparation of external/internal surfaces of panel boards/Feeder pillar boxes, consoles etc by scrubbing /CTC by emery paper by removing stains/rusted scales etc, and applying two coats of synthetic enamel paint complete and cleaning meters/indicators / MES Nos, making good and write preparation date completeetc complete all as specified and as directed. |
| 68 | Taking down aviation obstruction light any type / cap from the top of the OH water reservoir of approx 15 to 18 m above the ground level by means of safety staging /safety belt hook-up etc, removing the electrical connections and fixing back the new LED aviation obstruction light atsame in position with necessary modifications / PCC work and as desired by the Engr-in-Charge to make the fittings in smooth serviceable condition and testing and making good the disturbed complete and as directed. Note : (i) Replacement of aviation obstruction light shall be measured and paid separately under relevant item as \"supply only\" (ii) Replacement of cable and saddling down tank shall be measured and paid separately(iii) Necessary climbing arrangements like safety rope sys/Scaffolding/ ladders etc for repairing/removing /refixing the fittings should be included in the quoted rate. |
| 69 | S&F in repairs LED street light fitting of capacity 90W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 9900 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Note: (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items) |
| 70 | S&F in repairs LED street light fitting of capacity 70/75W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 7920 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Note: (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items) |
| 71 | S&F in repairs LED street light fitting of capacity 60W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 6600 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Note: (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items) |
| 72 | S&F in repairs LED street light fitting of capacity 45/50W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance of IK07, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Note: (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items) |
| 73 | S&F in repairs integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 200WLED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length withfixed to pole/wall, etc and testing complete all as specified and directed. |
| 74 | M&L in repairs earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steelbars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing inclduing taking down old one complete all as specified and as directed. |
| 75 | Surface dressing of installation/sub station area by removing of grass, creepers, etc. from roof of the building, in fencing and surrounding area of installation building complete all as specified and as directed. |
| 76 | Prunning of tree not exceeding 10mm girth including cutting of trunk branches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed. |
| 77 | Prunning of tree not exceeding 15mm girth including cutting of trunk branches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed. |
| 78 | Prunning of tree not exceeding 20mm girth including cutting of trunk branches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed. |
| 79 | Prunning of tree not exceeding 25mm girth including cutting of trunk branches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed. |
| 80 | Prunning of tree not exceeding 30mm girth including cutting of trunk branches and stacking of serviceable material and disposal of unserviceable materials to a distance not exceeding 50 m and clearing complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy