| 1 | Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer-in-Charge. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : i) Of area 3 sqm and below. |
| 3 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc.complete as per direction of the Engineer- in-charge:-In cement mortar |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.i) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size) |
| 5 | First class brick work in foundation and plinth including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 6 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 7 | Charges for fixing corrugated G.S. Sheet roofing fixed with polymer coated J or L hooks 8 mm diameter, bolts and nuts 6 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with lead and including a coat of approved steel primer and two coats of approved epoxy paint on overlapping of sheets complete ( upto a pitch of 60 degrees ) over a built structure including all types of necessary scaffoldings etc.but excluding the cost of the C.G.S. sheets, purlins, rafters and trusses etc.as per clauses of Chapter - 12 of CPWD specification.a) 0.63 mm thick with zinc coating not less than 275 gm / m2 |
| 8 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.i) 0.63 mm thick with zinc coating not less than 275 gm / m2 |
| 9 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-Using flates 30 x6mm for diagonal braces and central cross piece. |
| 10 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.i) Fixed to steel windows by welding. |
| 11 | Steel work in built up tubular( round , square or ractangular hollow tubes etc) trusses etc. includng cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, in/c welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 12 | Providing and fixing M.S. round holding down bolts with nutsand washer complete as per standard design. |
| 13 | 12 mm cement plaster of mixIn Cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 14 | Neat cement punning . |
| 15 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. all complete as per direction of Engineerin-charge.i) 40 mm thick with 20 mm well burnt brick aggregate |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:i) Two or more coats on new work |
| 17 | Painting on G.S. sheet with synthetic enamel paint ( two or more coats ) of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : i) New work (two or more coats) including a coat of appropriate steel primer but excluding a coat of mordant solution1x 2 nos schemex 105.48 sqm = 210.96 sqm |
| 18 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 19 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineerin-charge. 1 x 1 no= 1 no |
| 20 | Providing &fixing ofGI . Bend , elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the EIC. i. 125 mm dia. |
| 21 | ii) 150 mm dia |
| 22 | Providing & fitting fixing MS tail piece with MS flange suitable forpipes complete as per CPWD Specification & direction of Engineer-in-charge.i) 125mm dia pvc pipe 1 x 2nos = 2 nos |
| 23 | ii) 150 mm dia pvc pipe 1x 2 nos = 2 nos |
| 24 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.i) 125 mm dia. A. PN - 1.6 |
| 25 | (ii) 150 mm diaA. PN-1.6 |
| 26 | Providing and fitting fixing of M.S. flange ( 8 mm wall thickness) by welding withGI/MS pipe and placing possion as per specification and the direction of the EIC.i) 150 mm dia |
| 27 | ii) 125 mm dia |
| 28 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavate dsoil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge.A) All kinds of soil.a) For pipe not exceeding 90mm dia . |
| 29 | b) For pipeexceeding 90 mm dia but not exceeding 300 mm dia . |
| 30 | Providing and laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineer-in-charge.i) 90 mm dia |
| 31 | ii) 110 mm dia |
| 32 | iii) 140 mm dia |
| 33 | iv) 160 mm dia |
| 34 | v) 200 mm dia |
| 35 | vi) 315 mm dia |
| 36 | Providing and fixing GI. Pipes Medium class as per IS: 1239 with latest amendmentcomplete with GI. Fittings i/c trenching and refilling,cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer -in- charge.A. External work.i) 150mm dia nominal bore |
| 37 | Providing and fitting fixing of G.I hydrant suitable for PVC pipes asper standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve).80X50 mm dia.Fatikcherra - I :1 x 19 nos =19 nos |
| 38 | Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of working pressure 4.0 kg/sq.cm confirming to IS: 10124 (part-V) as per CPWD Specification & direction of Engineer-in-chargei) 315x315x250 mm dia |
| 39 | ii) 200x200x160 mm dia |
| 40 | iii) 160x160x140 mm dia |
| 41 | iv) 160x160x110 mm dia |
| 42 | v) 160x160x90 mm dia |
| 43 | vi) 140x140x110 mm dia |
| 44 | viii) 140x140x90 mm dia |
| 45 | ix) 110x110x90 mm dia |
| 46 | Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with steel primer(tailpiece if required will be paid separately) including proper alignment with pipe line & earth cutting, backfilling complete as per direction of Engineer-in-charge |
| 47 | Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-in-charge. (Payment of couplers, tees, reducers etc will be made separately)i)315 mm dia |
| 48 | ii)250 mm dia to 110 mm dia. |
| 49 | iii)90 mm dia. |
| 50 | Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in -charge.i) 90 mm dia. |
| 51 | ii) 110 mm dia. |
| 52 | iii) 140 mm dia. |
| 53 | iv) 160 mm dia. |
| 54 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints completeas per CPWD specification and direction of the Engineer - in -charge. i) 160 x140 mm dia |
| 55 | ii) 140 x110 mm dia |
| 56 | iii) 110 x90 mm dia |