| 1 | Appendix A: Maintenance and repairs to the U.G.Men\"s hostel -Electrical Work |
| 2 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 3 | 1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | od145213/2024_2025 : Supply and fixing of 20W LED Tube with fitting. Luker/Philips mushroom 20W<br>all complete. |
| 5 | 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 6 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 7 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 8 | od145227/2024_2025 : Providing, Installation, testing and commissioning of street light 40/45 W LED<br>(Philips, Bajaj, Luker or Equivalent) |
| 9 | 90.15.4.4 : Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 10 | od154341/2024_2025 : Supply, conveyance,testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -1 star rated ceiling fan complete with 300 mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C.<br> |
| 11 | Appendix A: Maintenance and repairs to the U.G.Men\"s hostel:civil work |
| 12 | 50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 13 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | 12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 16 | 12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) |
| 17 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 18 | od147348/2024_2025 : Preparation of existing floor to provide granite/ ceramic/ vitrified flooring in cement mortar by chipping floor/ cutting grooves manually/ by mechanical means including disposal of materials within 50 meters lead mas per direction of Engineer-in charge. in all floors |
| 19 | od147356/2024_2025 : Providing and laying rectified Glazed Ceramic floor tiles of size 400 x 400 mm*7-8mm, of 1st quality conforming to IS:15622, of matching colour of existing tiles and laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness laid on floors |
| 20 | od147477/2024_2025 : Providing and laying rectified Glazed Ceramic floor tiles of size 400 x 400 mmx7-8mm, of 1st quality conforming to IS:15622, of matching colour of existing tiles and laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness in skirtings, risers of steps. |
| 21 | 15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet |
| 22 | od183831/2024_2025 : Engaging fitter |
| 23 | od184047/2024_2025 : Engaging coolie for petty works |
| 24 | 15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 25 | 13.65.1 : Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 26 | 50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete |
| 27 | od184490/2024_2025 : Providing and fixing double scaffolding system (cup lock type) and polythene green net on the exterior side, up to seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . |
| 28 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 29 | 26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc.with manual Chisel and/ or by standard power driven percussion type or ofapproved make including tapering of all edges, making square shoulders ofcavities including cleaning the exposed concrete surface and reinforcementwith wire brushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In-Charge25 mm average thickness |
| 30 | 26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a totalrust free steel surface by using alkaline chemical rust remover of approvedmake with paint brush and removing loose particles after 24 hours of itsapplication with wire brush and thoroughly washing with water and allowingit to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter |
| 31 | 26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chippedportion of RCC as per specifications and direction of Engineer-In-chargecomplete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2kg cement per sqm of surface area mixed with specified proportion of approvedpolymer |
| 32 | Appendix A: Maintenance and repairs to the U.G.Men\"s hostel:drain works |
| 33 | od179681/2024_2025 : LiftingtheR C C covering slab of any thickness on top of drain and relaying after cleaning the drain in position including all labour charges miscellaneous expense etc. complete |
| 34 | od183397/2024_2025 : Cleaning and desilted solid waste of drainage, including removal of rubbish mixed with earth etc in to safe place so that it may not cause any nuisance or health hazard including lead of 50 m . and disposal of same, all as per the direction of Engineer-in-charge. |
| 35 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 36 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 37 | 5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 38 | od184367/2024_2025 : Cleaning of leach & manhole including removal of sludge by suction and disposal at a safe place so that it may not cause any nuisance or health hazard by cesspool machine (The cesspool machine, suction pipe and necessary all equipment at site are to be provided by contractor). |
| 39 | 50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall |
| 40 | 50.18.9.22.6 : Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 41 | od184520/2024_2025 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 200 mm dia 4 Kg/cm2 |
| 42 | od184521/2024_2025 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC<br>pipes,<br>including jointing with PVC solvent cement-200 mm dia Elbow |
| 43 | Appendix B:Repairs to toilets at First Floor Over Lecture Hall IV |
| 44 | 15.23.2Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm. |
| 45 | 14.1.2Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to thedumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand) |
| 46 | 50.4.1.1Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc. |
| 47 | OD29430/2024-2025Providing and fixing PVC floor trap of size 110 mm including necessary labourcharges as per the direction of the Engineer in charge |
| 48 | 18.8.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes |
| 49 | 18.7.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brassthreaded fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer -in-Charge. Internal work -Exposed on wall25 mm nominal outer dia pipes |
| 50 | 50.18.7.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall |
| 51 | 50.18.9.19.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This includes jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 -External work - Exposed on wall |
| 52 | 50.18.8.7.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed workincluding cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 53 | 50.17.1.4Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 54 | 11.37Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to bespecified by the manufacturer), of 1st quality conforming to IS : 15622, of approvedmake, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 55 | 11.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete. |
| 56 | 14.43Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 57 | 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 58 | 14.54.1Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work |
| 59 | OD29432/2024-2025Engaging Mason |
| 60 | OD29436/2024-2025Engaging pipe fitter |
| 61 | 50.18.9.22.3Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 62 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 63 | 18.49.1Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931.15 mm nominal bore |
| 64 | 50.18.9.20.3Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 65 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 66 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 67 | 18.58.2.1 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating |
| 68 | OD29477/2024-2025Pointing with Eposy Adhesive in joints including racking the existing joints, cleaning,application as per the direction of engineer in charge. |