| Sl. No. | Item Description |
| 1 | Road Delinator Delineator: Supply & Fixing of M S Delineator made of Mild steel with pure polyostor powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion The surface should De concealed so that there should not Be any exposed surface without powder coating. Alternatively, these metal guide poles can be concealed with thermoplastic body The posts shall have Ian ellipsoidal or circular design with the height of tho pole shall be 800 to 900 mm above the ground with about 200 to 300 mm Base which can be anchored onto the ground Mild steel Guide Poles shall conform to Type XI sheeting specifications as per IRC:87 and ASTM D4956 which would ensure to obtaml clear visibility of the road alignment during night time The Retro reflective sheeting shall Be tested for A certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shnnkage. flexibility. Imer removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor woalhenng and its having passed these tests shall Be obtained from Inlomational/Govornment Laboratory / Institute By the manufacturer of the sheeting and in case the certificate is obtained from international condition. It should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad Alternatively, a certificate conformirg to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weatnertng of the sheeting as per IRC 67.2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour TSP, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge (All rates are including all taxes but excluding GST) |
| 2 | 6M Span over head Cantilever Structure with 300 dia M S one vertical postSupply, fixing & eraclion of built up Cantilever Structure 6 m span compnsing of one vertical posts of 6 00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top A 12 mm M S plate at bottom. The horizontal Truss shat compose of 50 mm dia heavy class M S pipe and 40 mm dia heavy M S pipe as Bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design A drawing with one of steel primer and two coats of synthetic onamel plant. The work Includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 cement coarse sand and 40 mm gauge stone ballast and RCC - M25 grade concrete mdudmg supply and fixing of 25 mm da Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement. A shuttering. The lateral vertical clearances and complete Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC-67:2012 complete in all respect. The Rates shall include cost of design fabrication, supply, transportation Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. alt T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. (All rates are including all taxes but excluding GST) |
| 3 | 12 m-15 m Span Over Head Structure with 300 dia M S - two vertical post Supply, fixing 4 eraction of built up Overhead Structure of 12M-15M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top 4 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M S pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel paint. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1 3:6 (cement coarse sand and 40 mm gauge stone ballast and RCC M-25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement 4 shuttering. The lateral vertical clearances and complete, installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC-67:2012 complete In all respec.t The Rates shall include cost of design, fabrication, supply transportations, Local shifting Erection of signage structure using crane, inclusive of all taxes etc all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in charge. (All rates are including all taxes but excluding GST) |
| 4 | Linear Delineator System (LDS) Supply & fixing of Linear Delineator System (LDS) panels made of Micro Pnsmatic Retro Reflective sheeting type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide Retro Reflection across wide range of observations and external angles. Each LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 Inch high. Each LDS panel is to be firmly fixed on existing concrete/brick work with 16 Nos fastner/ screw (All rates are including all taxes but excluding GST) |
| 5 | Retro-Refloctive Sheeting type-XI with 4 mm thick ACM Double Side Providing & fixing of reflective signs with a corrosion resistant 4 mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High Intensity prismatic sheeting type IV as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5 mm Legends . letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 The sheeting shall have a pressure - sensitive adhesive of the aggressive - tack type requiring no heat solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacturer. The ACM (Aluminium Composite Materials) shall be fixed on the Back frame MS Angle with riveting Micro prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 shall be Pressure fixed The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility liner removal, adhesion, impact resistance, specular gloss and fungus resistance. 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and In case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client. if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathenng of the sheeting as per IRC 67 2012 4 Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour. T&P. transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge (All rates are including all taxes but excluding GST) |
| 6 | Solar Power road marker (Solar Studs)The solar studs shall be made of Aluminium alloy and poty carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13.635 kg tested in accordance with ASTM D4280 its colour may be white . red . yellow . green or blue or combination as directed by the Engineer Its water resistance shall meet the requirements of IP 65 in accordance with IS:12063:1987 category 2 for protection against water ingress. The dimensions of solar studs shall not be less than 100 mm X 100 mm X 10 mm. it shall have super bright LEDs so as to provide long visibility from a distance of more than 800 m. Its flashing rate shall not be less than 1 Hz. its should be able to give the prescribed performance in the temperature range of - 40°C to 55°C. Its life shall be not less than 3 years. The rate shall include all materials, labour, equipment, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-charge.(All rates are including all taxes but excluding GST) |
| 7 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)90 cm equilateral triangle with diffinitation plate size (20 cm x 60) |
| 8 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)60 cm equilateral triangle with diffinitation plate size (20 cm x 60) |
| 9 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)60 cm Circular with diffinitation plate (20 cm x 60 cm) |
| 10 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)90 cm high Octagon |
| 11 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)30 x 90 cm (Left/Right) Object Hazard |
| 12 | Retro-reflectorised Traffic sign as per IRC:67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67:2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminum sheeting 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for a cetificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years of outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/Institute by the manufacture of the sheeting and in case the certificate is obtained from international condition.It should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation the Employer / Client, if so desires could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends letters numericals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded white quoting tender.(All rates are including all taxes but excluding GST)45 x 90 cm two way Object Hazard |
| 13 | Direction and Place identification signs up to 0.90 sqm size BoardProviding and erecting direction and place identification retro-reflectonsed sign as per IRC-67 made of high intensify grade sheeting. The Retro reflective sheeting shall be tested tor a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance. 3 years outdoor weathering and its having passed these tests shall be obtained from Intemational/Govemment Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming lo ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be acceptod provisionally In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends, letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 Sheet fixed over aluminium sheeting 2 mm thick with area not exceeding 0.9 sqm. Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm .below ground level as per approved drawing, complete (All rates are including all taxes but excluding GST) |
| 14 | Direction and place Identification signs with size more than 0.90 sqm size BoardProviding and erecting direction and place identification retro-reflectonsed sign as per IRC-67 made of high intensify grade sheeting. The Retro reflective sheeting shall be tested tor a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance. 3 years outdoor weathering and its having passed these tests shall be obtained from Intemational/Govemment Laboratory/ Institute by the manufacturer of the sheeting and in case Iho certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching ol product by tho manufacture in abroad. Alternatively, a certificate conforming lo ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be acceptod provisionally In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificale meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends . letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 Sheet fixed over aluminium sheeting 2 mm thick with area not exceeding 0.9 sqm Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm .below ground level as per approved drawing, complete (All rates are including all taxes but excluding GST) |
| 15 | Tree Plate/Name PlateSupply & Fixing of Retro reflective Tree Plate having size 20cm x 30cm, consisting Type XI Retro reflective Sheeting fixed. Over 1.50 mm thick aluminium sheet including labour, Material T&P etc for proper completion of the work. The rate shell include all materials,labour, T&P, Transportation installation and incidential all complete as per direction of the Engineer-in-charge. (All rates are including all taxes but excluding GST) |
| 16 | Retro Reflectonsed Signs (Stainless steel Frame and Post with both side signs) Supply & fixing of reflective sign board (single side) of size 1.50x1.20 m retro reflective sheeting of HIP grade type-IV. the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick ACM sheet of standard make as per MORTH specificaton. The board shall be fixed using 2 man post 45x45x60 cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder property including bulling so an to give uniform shining at weded joints. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from Intemational/Govemment Laboratory/ Institute by the manufacturer of the sheeting and In case the certificate is obtained from International condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4656-09) on artificial accelerated weatherng requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, If so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends . lelters . numerals and borders etc should be as per MoRTH specification No-801 3.7 Proof of the same In form of government report shall be uploaded while quoting tender. (All rates are including all taxes but excluding GST) |
| 17 | Retro Reflectorised Signs (Stainless steel Frame and Post with both side signs)Supply & fixing of reflective sign board ( both side) ol s*e 1.50x1.20 m retro reflective sheeting of HIP grade type-IV. the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick ACM sheet of standard make as per MoRTH specification. The 8oard shall be fixed using 2 man post 45x45x60 cm cement concrete foundation.The stainless steel joint welding of SS pipe work shall bo band and grinder property including bulling so an to give uniform shining at weded joints. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from Intemational/Govemment Laboratory/ Institute by the manufacturer of the sheeting and In case the certificate is obtained from International condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, If so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends . lelters . numerals and borders etc should be as per MoRTH specification No-801 3.7. Proof of the same in form of government report shall be uploaded while quoting tender (All rates are including all taxes but excluding GST) |
| 18 | 2.40 M Span over head Cantilever Structure with 150 dia MS one vertical post (Double side retro reflective sign boards)Supply, fixing & eraction of built up Cantilever Structure 2.40 m span composing of one vertical posts of 7.30 M height made up of 150 mm NB medium class MS pipe as vertical member welded with 10 mm MS plate at top & 10 mm MS plate at bottom fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant and The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested tor coefficient ol retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and lungus resistance. 3 years outdoor weathering and its having passed these tests shall be obtained from Inlemational/Govemment Laboratory/ Institute by the manufacturer of the sheeting and in case lie certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad Alternatively a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed aboratory In India can be accepted provisionally In such a situation, the Employer / Client, it so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 Legends . letters . numerals and borders etc should be as per MoRTH specification No-801 3.7 The work includes construction of RCC Foundation of size 0.60x0.60x1.20 m of required depth as per site condition for built up structure Including Earth work in excavation 100 mm thick Lean Concrete In 1 3:6 cement coarse sand and 40 mm gauge stone ballast. RCC M25 including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete installation work shall be as per relevant clauses of MoRT&H specification section 800 and IRC 67 2012 complete In all respect. The Rates shall ncfude cost of design fabroation. supply transportation Local shifting Erection of Signage structure using crane, inclusive of all taxes etc all T&P machine. material and labour required for proper completion of work as per direction of Engineer-in-charge (All rates are including all taxes but excluding GST) |