Providing, Installation Of Pumping Machineries With Other Electro Mechanical Accessories For Augmentation Work Of 06 Nos Ohr Under Saltora Chhatna Water Scheme Under Bankura Mechanical Division, Phe Dte. Block Saltora , Dist Bankura=-2 Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE 3 star minimum rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) and as per technical specification givebn in NIT Method of starting – star deltaTube Well size-250mma) Discharge-5 M3/Hour, Total head -62 MtrN.B-T.C. & G.C. needed. (Manufacturer test certificate along with curve chart should be submitted at the time of delivery) (Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 3 Supply and delivery of the following materials at site : - 4 Supply, delivery and storage at site 50 mm dia UPVC Column pipe medium gauge both side 8 TPI threaded and one side heavy type socket other site rubber cap for threaded protector Standard (17kg/cm2). (Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 5 1.5 mtr long 6 3 mtr long 7 Supply and delivery at site 50 mm dia CI Top Adaptor with flange (Single clamp) 8 Supply and delivery at site 50 mm dia CI Bottom Adaptor(small) 9 Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland 10 Safety device for the above pump set by supplying MS cage with proper clamping arrangement andRound Twisted Machine Made Nylon rope 20 mm dia (super quality)as per requirement including supply of all required materials with nuts and bolts as required 11 102mm Ф 0-12 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings 12 Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mm dia pipe (Size-300 mm x 80 mm x 8 mm each) 13 Supply and delivery of following valves 14 80 mm dia CIDF single door swing check Non Return valve(P.N-1.0) generally conforming to IS 5312 Part I fordelivery line and as per technical Specification given in NIT. 15 80mm dia CIDFnon-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846 and as per technical Specification given in NIT . (for 1 no by pass arrangement ) 16 102mm Ф 0-7 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings 17 Supply and delivery of 80mm diafollowing GI specials for delivery line 18 Tee 19 Pipe (TATA Medium) (including Socket 20 Bend (90) 21 flange (G.I) heavy type for 80 mm dia 22 Plug 23 Socket 24 Supply and delivery of 32mm diafollowing GI specials for Cable Protection 25 100mm long short piece (50mm upto 150mm long) 26 Bend (90) 27 Union 28 Pipe (TATA Medium) (including Socket) 29 Supply, delivery and storage at site of following cables 30 2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date.(Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 31 16 mm2 4 Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments.(Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 32 Supply, deliveryat site of following items 33 Supplying delivery of 63 Amps 415 Volt TPN Sheet steelenclosed re-wireable fuse type Main Switche with side handle operated. (Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 34 Supplying delivery of 63 Amps 415 Volt TPN Sheet steelenclosed Onload Changeover Switch side handle operated. 35 Supply deliveryof wall mounted 415 Volt TPN sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as requiredi)63 Amp 4way 36 Supply and delivery of 415 Volt MCC cum PDB with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus Bar, Digital Voltmeter, Ammeter, contractor, delay timer, MCB, Valve actuator stater etc. with PLC logic & UPS and detailed in as per tecnical specification given in NIT. i) 5-7.5 H.P withDOL StarterN.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel.(Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 37 Supplyand deliveryoil coolling type Voltage Stabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NITN.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery(Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 38 i) 15 KVA for Pump House 39 Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2 mm shank thickness ceilling fan 40 Supply deliveryof outdoor typeLED light fixture Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.M.No-BRP409 LED130 CW SLC FG PSU GR V2 or Equivalant modelof Philips make or equivalent model. 41 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).a) 40 mm dia [ for Control Cable protection] 42 a) Supply, delivery and automatically controlled planger type chlorinator dosing pump with Flow Rate 0-100 Ltr./Hr. and Max pressure of 10kg/cm2) with all relive valve and diaphragm rupture indicator , pressure gauge , parure switch, base plate, flexible coupling guard for pump and Motor, foundation bolt,dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1440 RPM (+-4%) squirrel cage TEFC induction Motor, Motor will be IE3 (Materials will be received as per requerment of the dept , numberof material will be received after the approval of the dept , no extra material will be received in this case) 43 PART-B 44 a) Installation and commissioning of the above PLC automatic panel with pumping machinery,Voltage Stabiliser,of item no (1 to 16)outdoor lighting, outdoor type actuater making delivery line, washoutline by the G.I specials, with cable protection pipe,including cable finishing, supplying ofall necessary metrials andincluding necessary finicing of serounding area of T/Wby the brick works, plastering, Net finishing etc and cost of hiring D.G set ( if required) to complete the jobs includingLaying of two nos 2.5 sqmm 3 coreCablein an underground trench, Laying of 1.5Sq mm control cable through 40 mm dia PVC Schedule-80 pipe in under ground trench, Laying of cable from 3/3½ core up to 25 sqmm on wall/surface andPainting of anty corrosive paint in all respect as per tecnical specification and as per direction of E.I.C. 45 b) Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire(approved make) from installed panel board through 20mm size PVC rigid conduct FR(Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine) 46 Making 300mm(W) x 300mm(B) x 900 mm (H) size rising main supporting brick pillar at least 300mm depth from ground level to pumping floor level and neat cement finish all complete as per direction. 47 Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil 48 Earthing with 50mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI (hot dip ) wire (4 mts long) , 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl S & F 15 mm dia GI Pipe protection ( 1 mtr long ) to be filled with bitumin purely under the ground level and partly above ground level driven to the averagedepth of 3.65 Mts. below the ground levelas below:By ISI-Medium GI pipe 49 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe 50 Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 51 Add: 18% GST 52 Add: 1% Cess