}

Providing And Installation Of Boosting Pumping Machineries And Other Electromechanical Accessories At Tail End For Augmentation Work For Mandalkuli (Iiib) Under Raipur Block Water Supply Scheme Under Bankura Mechanical Division, P.H.E. Dte, bankura-West Bengal

Public Health Engineering Department has published Providing And Installation Of Boosting Pumping Machineries And Other Electromechanical Accessories At Tail End For Augmentation Work For Mandalkuli (Iiib) Under Raipur Block Water Supply Scheme Under Bankura Mechanical Division, P.H.E. Dte. Submission Date for this Tender is 21-03-2025. Pumping Machiney Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

47985544
Providing And Installation Of Boosting Pumping Machineries And Other Electromechanical Accessories At Tail End For Augmentation Work For Mandalkuli (Iiib) Under Raipur Block Water Supply Scheme Under Bankura Mechanical Division, P.H.E. Dte
Open Tender
Indian
West Bengal
Bankura
21-03-2025

Tender Details

Providing And Installation Of Boosting Pumping Machineries And Other Electromechanical Accessories At Tail End For Augmentation Work For Mandalkuli (Iiib) Under Raipur Block Water Supply Scheme Under Bankura Mechanical Division, P.H.E. Dte- 1 PART-A ForNEW PUMP HOUSE (at tail endand OHR site) 2 Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE3star(minimum) rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category Bmotor) as per NIT 3 Discharge-8.5 M3/Hour, Head -64 Mtr for tail end boosting 4 Supply, delivery and storage at site 50 mm dia UPVC Column pipe medium gauge both side 8 TPI threaded and one side heavy type socket other site rubber cap for threaded protector , Standard (20kg/cm2). 5 a) 1.5 Mtr. Long 6 b) 3.05 Mtr. Long 7 Supply and delivery at site 50 mm dia CI Top Adaptorwith flange (Single clamp) 8 Supply and delivery at site 50 mm dia CI BottomAdaptor (Single clamp) 9 Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mmdia pipe (Size-300 mm x 80 mm x 8 mm each) 10 Split type MS fabricated suitable tubewell cover as pertubewell housing with a necessary arrangement forclamping devices including holes for air pipe and cable entry gland 11 Safety device for the above pump set by supplying MScage with proper clamping arrangement and RoundTwisted Machine Made Nylon rope 20 mm dia (superquality)as per requirement including supply of allrequired materials with nuts and bolts as required 12 102mm Ф 0-12 Kg / cm2 pressure gauge with brass threeway cock and syphone and other necessary fittings 13 Supply & delivery at site following Valves 14 Supply & delivery at site & storage CIDF single door swing checkNRV rating asper IS:5312 Part – I, and as per technical Specifications given in NIT(for individual L/L Pump) 15 i) DN 80 mm(P.N.–1.0) (for Submersible delivery header) 16 CIDFnon-rising Sluice Valve ) generally conforming to IS 14846as per technical Specification given in NIT 17 i) DN – 80mm (P.N-1.0) for wash out line 18 Supply and delivery ofthree phase actuator operated wafer type butterfly valveas per Bs-5155and as per technical Specification given in NIT 19 i) DN 80 mm(PN-1.0) (for L/Ldelivery header) 20 Supply delivery and storage at site of Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicatoras per technical specification 21 i) DN 80 mm(PN-1.0) (for L/Ldelivery header) 22 Supply and delivery of 80mm dia following GI specials for delivery line 23 Tee 24 Pipe (TATA Medium) (including Socket) 25 Bend (90) 26 Flange (G.I Threaded) heavy type 27 Plug 28 Socket 29 Supply and delivery of 32mm dia following GI specials for Cable Protection 30 100mm long short piece 31 Bend (90) 32 Union 33 Pipe (TATA Medium) (including Socket) 34 Supply, delivery at site of following Electricalitems 35 Supplying delivery of 63Amps 415 Volt TPN Sheet Each steel enclosed re-wireable fuse type Main Switche with side handle operated.Make: havels/ standard/phe approved 36 Supplying delivery of 63 Amps 415 Volt TPN Sheet steel enclosed Onload Changeover Switch side handle operated. 37 Supply and fitting fixing of wall mounted 415 Volt TPN sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as requiredi) 63 Amp 4way 38 Supply, delivery and storage at site of following L.T cables 39 2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date. 40 16 mm2 4 Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, (From WBSEDCL meter to MCC & through Voltagestabilizer) 41 10 Sq. mm 3 core, 1.1 KV grade, Al. Ar XLPEAcable conforming to As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,a) Sub mersible motor starter to Kiox box x 50mtr 42 1.5 sq mm , 12 core , 1.1 KVGrade PVC insulatedCopper Armoured control cable as per relevent IS. 43 4 Sq. mm 2 core, 1.1 KV grade, Al. XLPEAcable conforming to IS : 7098 (Part – I).For Lighting 44 Supply and delivery of 415 Volt MCC cum PDB with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus Bar, Digital Voltmeter, Ammeter, contractor, delay timer, MCB, Valve actuator stater etc. with PLC logic & UPS and detailed in as per tecnical specification given in NIT. i) 5-7.5 H.P with DOL(direct On -Line) StarterN.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel. 45 Supply and deliveryoil coolling type VoltageStabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NITN.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of deliveryi) 10 KVA 46 Supply, delivery and automatically controlled planger type chlorinator dosing pump with Flow Rate 0-100 Ltr./Hr. and Max pressure of 10kg/cm2) with all relive valve and diaphragm rupture indicator , pressure gauge, parure switch, base plate, flexible coupling guard for pump and Motor, foundation bolt, dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1440 RPM (+-4%) squirrel cage TEFC induction Motor, Motor will be IE3 47 Supply delivery at site of additional 100 ltr capacity PVC chlorine solution tank 48 Supply delivery of outdoor type LED light fixture /setOperating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set. M.No-BRP409 LED130 CW SLC FG PSU GR V2 of Philips make or equivalent model. 49 Supply and delivery of 450mm(H) x 300(L) x 250mm(B) size out door CRCA sheet steelfabricated cubical type kenopy top cable jointing box inside fitted3 nos 63 Amp rated bus bar andhinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C 50 Supply delivery80mm diaM.S Black pipe Medium (Class B) as per IS:1239 PART-1 (2004). i) 1.5 mtr long each x 2 nos=3mtr(For holding Arm at Pump House Roof) 51 Supply delivey of 1.5 mtr. long M.S Arm bracket made out of40 mm dia MS pipe with painted anticorrosive paint . 52 Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting250 x 250 x 100mm 53 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).a) 40 mm dia [ forCable protection] 54 PART-B (Intallation for Deep tube well) 55 a) Installation & commissioning of the above PLC automatic panel with pumping machinery,Voltage Stabiliser,of item no (1 to 32) excluding item no-[20,21,25and 32] outdoor lighting,Actuater, making delivery line, washoutline by the G.I specials, with cable protection pipe,including cable finishing, supplying ofall necessary metrials andincluding necessary finicing of serounding area of T/Wby the brick works, plastering, Net finishing etc and cost of hiring D.G set ( if required) to complete the jobs including Painting of anty corrosive paint in all respect as per tecnical specification and as per direction of E.I.C. 56 Installation & commissioning of above chlorinatorwith supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire (approved make) from installed panel board through 20mm size PVC rigid conduct FR (Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entireset as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine, chlorine machine and related items will be supplieddeparmentally ) 57 Laying through Underground TrechLaying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brickprotection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed 58 Making double Earthing arrangement in compliencewith I.E rules by G.I pipe electrode with G.I funnel (50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete. For MCC Panel & Voltage Stabilizer 59 Making internal wiring /electrification of Pump House by 2x 22/0.3(1.5DSq mm + 1x22/0.3(1.5sqmm) singlecore PVC insulated multistranded FRLSH grade flexiblecopper wire through 20mm PVC conduit pipe/cashing by supplying one no 40Amp, 10KA , 240/415V , 50HZ, SPN/DP MCB isolator conforming to IS/IEC:60947-3, C characterise / As per approved vendor list of PHEDvide no-PHE/IV/2277/W-181/19 dated-25-09-21 withrequired model PVC Board & Piano key type switch(Avg Run 6mtr). i) LED Tube Set point-2nos, Bulk Headlight point-1no each with necessary earthingarrangement & one fan point(Total point6nos)including drawing power DB through 20mm PVCcashing caping (precision make) as per direction ofEIC(fitting cut-out to SPN/DP MCB wiring should be with continuous earthing arrangement and 20W twono’s x 4ft long LED tube light make-Philips, Bulk Head light M.No- Endra WT202W LED6S NW PSU S2 PC one nno 0.4 Stap fan regulator fitting etc to be supplyed by agency 60 Supply delivery at site and storage of safety equipment like 6kg capacity Fire Extinguisher , sand bucket with bracket , rubber mats, shock treatment chart and first aid box, complete as per technical Specifications given in NIT 61 Supply and delivery of 2(Two) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT 62 Trial run of pumping machinery, through PLCAutomatic panel also operation of Pumping machineris,Chlorinator, Voltage Stabiliser etc. including operation of valves if required and guarding of installation as per direction of E.I.C.( for 90 days) for 1 persion 63 Add: 18% GST 64 Add: 1% Cess

Key Value

Document Fees
Refer document
EMD
INR 28000.0 /-
Tender Value
INR 14 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail