Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-03-2025 |
| Sl. No. | Item Description |
| 1 | Material & labour for Rewinding of electric motor of Cap 7.5HP- 12.5HP (Condensor and Chilled water Motor) three phase 415 volts by removing old u/s burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire ISI markedof suitable sizealong with insertion of superior quality of insulating material,winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding, replacement of connection plate and making necessary electric connection and testingcomplete all as specified and directed. |
| 2 | Material & labour for Rewinding of electric motor of Cap 2HP-5HP (Condensor and Chilled water Motor) three phase 415 volts by removing old u/s burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire ISI markedof suitable sizealong with insertion of superior quality of insulating material,winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding including, of connection plate and making necessary electric connection and testingcomplete all as specified and directed. |
| 3 | Decoupling of Monoblock Pump from electric motor, dismantling from the foundation and shifting to local workshopfor Repair/Overhauling of mono block pumping set 7.5 to 12.5 HP (Condensor and Chilled water Pump) taking out impeller bush bearing shaft stuffing box reassembling the same after replacing the defective parts & carrying out the necessary repair remetallingturning polishing the pump shaft replacement including replacement of steel studs and unserviceable nuts and bolts repair/replacement of ball bearing impellor stuffing box greasing etc and testing on completion and commisioning and installation at site complete all as specified and directed.Note:- (i) The complete job includes making good the existing pumps water leakage proof,including gland/packing etc. (ii) Cost of the Spare parts except GM bush, Impeller, stuffing box and ball bearing shall be included in the quoted rate by the contractorfor repair the pumpset. |
| 4 | Supply & fixing in replacement bearing for 7.5 to 12.5 HP pumpsets Make:- SKF/NBC complete all as specified and directed. |
| 5 | Supply & fixing in replacement Bronze/GM Impeller of pumpset of cap 7.5 to 12.5 HP complete all as specified and directed. |
| 6 | Supply & fixing in replacement Stuffing box alongwith pressure plate and hexa nuts studds etc required for Gland packing and Pump shaft as per existing make complete all as specified and directed. |
| 7 | Supply & fixing in replacement Gun metal Bush of pumpset of cap 7.5 to 12.5 HP complete all as specified and directed. |
| 8 | Decoupling of Monoblock Pump from electric motor, dismantling from the foundation and shifting to local workshopfor Repair/Overhauling of mono block pumping set 3 to 5 HP (Condensor and Chilled water Pump) taking out impeller bush bearing shaft stuffing box reassembling the same after replacing the defective parts & carrying out the necessary repair remetallingturning polishing the pump shaft replacement including replacement of steel studs and unserviceable nuts and bolts repair/replacement of ball bearing impellor stuffing box greasing etc and testing on completion and commisioning and installation at site complete all as specified and directed.Note:- (i) The complete job includes making good the existing pumps water leakage proof ,including gland/packing etc. (ii) Cost of the Spare parts except GM bush, Impeller, stuffing box and ball bearing shall be included in the quoted rate by the contractorfor repair the pumpset. |
| 9 | Supply & fixing in replacement bearing for 3 to 5 HP pumpsets Make:- SKF/NBC complete all as specified and directed. |
| 10 | Supply & fixing in replacement Bronze/GM Impeller of pumpset of cap 3 to 5 HP complete all as specified and directed. |
| 11 | Supply & fixing in replacement Stuffing box alongwith pressure plate and hexa nuts studds etc required for Gland packing and Pump shaft as per existing make complete all as specified and directed. |
| 12 | Supply & fixing in replacement Gun metal Bush of pumpset of cap 3 to 5 HP complete all as specified and directed. |
| 13 | Supply & fixing in replacement gland packing for Monoblock pumpset/Centrifugal end suction pumpset of capacity 2HP to 15HP; Make: As per existing and complete all as specified and directed. |
| 14 | Material & labour for periodical servicing of AHUs capacity 6000 CFM to 12000 CFM by opening air filter, nut bolts, tray for AHU including cleaning of air filter panel, cleaning of cooling coil bycoil cleaner solution and high pressure water and rectified refrigerant leakage in cooling coilcomplete with brazing and soldering,opening and disconnectning ofAHU motor fromblower room checkingseviceability fan, pulley, fan belt and oiling /greasing complete, replacement of unserviciable vibrating pads/springinside of AHUfor equal air flow from blower to difuserofany type/capacity blower complete all as specified and directed. |
| 15 | Material & labour for Rewinding of electric motor of Cap 5HP-10 HP (AHUs Motor) three phase 415 volts by removing old u/s burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire of suitable sizealong with insertion of superior quality of insulating material,winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding including replacement of connection plate and making necessary electric connection and testingcomplete all as specified and directed. Make of winding wire : RR cabels/kEI/Havells |
| 16 | Material & labour for Rewinding of electric motor of Cap 2HP-3HP (AHUs Motor) three phase 415 volts by removing old u/s burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire of suitable sizealong with insertion of superior quality of insulating material,winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding, replacement of connection plate and making necessary electric connection and testingcomplete all as specified and directed. Make of winding wire : RR cabels/kEI/Havells |
| 17 | Supply & fixing in replacement of 50 mm dia electronic, self balancing, pressure independent type dynamic balancing valve with integrated modulating control valves in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. Valve & Actuator combination should be able to give logarithmic control characteristics to achieve linear control.The valve shall have manual override facility & the scope shall include proportionate thermostat, transformer as required and wiringfor interconnection with 1.5 sq.mm copper conductor multicore armoured cable complete as required. Make:Honeywell, Siemens, Danfoss etc. |
| 18 | Supply & fixing in replacement of Pre fine Air filters panel of size as per gound for dust filtration of particles up to 5 microns at 99% efficiency having air velocity through the filter Approx 350 to 400 FPM AHU of Make : Zenith filters or equivalent to AFI/Spectrum/Asian filters complete all as specified and directed. |
| 19 | Supply & fixing in replacement of Micro filters size as per ground for dust filtration of particles up to 5 microns at 99% efficiency having air volume through the filter Approx 3500 cum per hour AHU of Make : Zenith filters or equivalent to AFI/Spectrum/Asian filters complete all as specified and directed. |
| 20 | Material & labour for repair and servicing of cooling towerof varying capacity 15 TR to 50 TR capacity AC Plant, Dismantling of cooling tower for removing of top cover andreplacement of PVC Frills and unserviceable nozzle, replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust complete all as specified and directed.Note:- Spare parts i.e. float valve, PVC Nozzelsshall be measured and paid separately. |
| 21 | Material & labour for repair and servicing of cooling towerof varying capacity more than 50 TR capacity AC Plant, Dismantling of cooling tower for removing of top cover andreplacement of PVC Frills and unserviceable nozzle, replacement of rusted nuts, bolts with washers etc and cleaning bottom tank to remove mud and dust complete all as specified and directed.Note:- Spare parts i.e. float valve, PVC Nozzelsshall be measured and paid separately. |
| 22 | Material & labour for Rewinding of electric Fan motor of Cap 2HP-5HP (different cooling towers) three phase 415 volts by removing old u/s burnt copper winding wire, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enameled copper wire ISI markedof suitable sizealong with insertion of superior quality of insulating material,winding, varnishing and drying, including dismantling of electric motors connections and refixing back after rewinding including replacement of connection plate and making necessary electric connection and testingcomplete all as specified and directed. |
| 23 | Material & labour for Descaling the condenser and chiller by recommended chemical cleaning agent by soaking method, disconnecting condenser from the system, taking out nuts bolts, studs, 2 Nos valves andMS/GI pipe line from both side cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4 mm thick suitable for AC plants installed as indicated below :- |
| 24 | Condenser and chiller at OT MH |
| 25 | Condenser and chiller at ICU MH |
| 26 | Condenser and chiller at Maternity ward |
| 27 | Material & labour for Cleaning of Air cooled Condenser by recommended chemical cleaning agent and with high pressure water machine as under:- |
| 28 | Air cooled Condenser at Raina Auditorium |
| 29 | Air cooled Condenser at Cold Storage MH |
| 30 | Material & labour for carry out leak test for the chiller type system by extracting the existing available gas from the system to separate cylinder storing and pressuretesting the complete system with dry nitrogen and check the leaks , identifying the leaks, rectification of leaks by brazzing / welding at the leak points/replacing by damaged valve gland package / gasket etc, and after rectification of all the leaks pressure testing the complete system up to 300 PSI at high side , 200 PSI at low side of the system, holding the pressure for 24 hrs and vaccumising the complete system after releasing the dry nitrogen and charging the refrigerent gas to system and testing & comissioning the plant checking all controls for the 25 TR capacity ofmake : Voltas / Blue star, shell and condensers all as directed by Engineer-in-charge.(Loc- Maternity ward MH and ICU MH) |
| 31 | All as per srl item No. 25 but capacity of 65 to 100 TR (Loc- OT MH and Raina Auditorium) |
| 32 | Material & labour for carrying out repairs and Maintenance , attending to breakdown of15 to 100 TRliquid/Air chiller central AC plant of Make : Voltas / Bluestar as per the following scope of the work given below including carrying out general repairs/ servicing to ensure smooth and trouble free operation of plants to the entire satisfaction of users/department complete all as specified & directed.( Maternity/ICU/OT/Raina Auditorium). |
| 33 | Scope of Work : (a) Periodicalmonitoring / Inspecting the complete ac plant and carrying out preventive/ periodical maintenance to ensure smooth functioning of AC plant.The periodical inspection for preventive maintenance shall be carried out by technician/service engineer of OEM once in a quarter other than breakdown calls for monitoring the operational condition of AC plant including for preventive maintenance/breakdown calls whenever required. Each preventive maintenance & breakdown call if any will be measured Job(b) Visual inspection for oil traces, Air heat exchanger (condenser) cleaning, check for removed protection devices, and improperly closed doors/ covers, check that the temperature difference between the heat exchange inlet and outlet is correct, check the refrigeration system, motors and starters for performance and healthy condition of plant.(c) Checking the system for leaks and rectification of leaks if any.(d) Taking a set of readings and evaluating the same to ensure the satisfactory performance of the plant.(e) Checking the refrigeration control system for operation and adjusting the settings as and when required. (f) General Cleaning of the evaporator and condensing coils(g) General Lubrication ofthe bearings of motors, pumps and fans as and when required.(h)Inspection of belts, which includes adjusting the tension including replacement if required.(j)Filling only the refrigerant as a result of leak arising from the system due to standard wear and tear.(k)Repairing/ replacing the components of the equipment at site or at workshop as required(l)To check properfunctioning of microprocessor and take control test.(m) Intimating any breakdown requiring specific major repairs/overhauling to the contractor/ department for immediate rectification of defect.(n) Attending the complaints/ breakdown whenever received by user /JE /Engineer in charge and attending the complaint for same within 24 hrs of receipt.(o)The repair/replacement of all spare parts like ICVC Boards, compressor / fan motor rewinding,electrical switch gears, contactors, PCB, refrigerant gas etc., are not in the scope. These items shall be measured and paid separately under relevant items.(p) Any minor spares/ repairs items which are required to keep the plant in operational condition are deemed to be included in scope of work. |
| 34 | Material & labour for Repair and replacement of unsv parts of existing Micro-processor BasedControl panel of Make : Voltas complete in all respect with all electrical switchgear including MCB C-50A : 03 Nos, Motor protection device and Single phase preventer VSP-3 Make Minilec : 03 Nos, Relay, sensing transformer :03 Nos, Contactor MNX50 :03 Nos, CT 100 / 5 A: 03 Nos , PCB with Display Unit: 01 Nosetcof the VoltasAir cooled chiller plant Cat Part No : ACDS070DPMN3X1 with R-22/407C refrigerant basedScroll type of 70TR Capacity Location: Raina Auditorium, complete all as specified and directed. Note: (i) Cost of replacement of Field Devices, Chilled Water Inlet Sensor and Outlet Sensor with their mounting and fixing accessories and High Pressure and Low PressureCut off switches of Make : Danfos/Indfos deemed to be included in the quoted rate. (ii) Cost of the control panel wiring must be included in the quoted rate by the contractor. |
| 35 | Material & labour for Repair and replacement of unsv parts of existing Micro-processor BasedControl panel of Make : Voltas complete in all respect with all electrical switchgearincluding MCB C-50A : 03 Nos, Motor protection device and Single phase preventer VSP-3 Make Minilec : 03 Nos, Relay, sensing transformer :03 Nos, Contactor MNX50 :03 Nos, CT 100 /5 A: 03 Nos , PCB with Display Unit: 01 Nosetcof the bluestarwater cooled chiller plant Cat Part No :ACWCDS039DMN3X1 with R-22/407C refrigerant basedScroll type of 37.5 TR Capacity. Location: OT MH, complete all as specified and directed.Note: Cost of replacement of Field Devices, Chilled Water Inlet Sensor and Outlet Sensor with their mounting and fixing accessories and High Pressure and Low PressureCut off switches of Make : Danfos/Indfos deemed to be included in the quoted rate. (ii) Cost of the control panel wiring must be included in the quoted rate by the contractor. |
| 36 | Material & labour for Repair and replacement of unsv parts of existing Micro-processor BasedControl panel of Make : Voltas complete in all respect with all electrical switchgearincluding MCB C-50A : 01 Nos, Motor protection device and Single phase preventer VSP-3 Make Minilec : 01 Nos, Relay, sensing transformer :03 Nos, Contactor MNX50 :01 Nos, CT 100 /5 A: 01 Nos , PCB with Display Unit: 01 Nosetcof the bluestarwater cooled chiller plant Cat Part No :WCDS-013DPMN1X1Pwith R-22/407C refrigerant basedScroll type of 12.5 TR Capacity. Location: ICU MH, complete all as specified and directed.Note: (i) Cost of replacement of Field Devices, Chilled Water Inlet Sensor and Outlet Sensor with their mounting and fixing accessories and High Pressure and Low PressureCut off switches of Make : Danfos/Indfos deemed to be included in the quoted rate. (ii) Cost of the control panel wiring internal/external deemed to be included in the quoted rate by the contractor. |
| 37 | Disconnecting from mains and Supply & fixing in replacement of Compressor-scroll type ,380 to 400V, 3 phase, 50 HZ, Thermally protected, Lubricant mineral oil-160P, Refigerant type R-22/407C of Cap-12.5TR(Nominal Cooling capacity at 50Hz, 41.1 KW) of Make- Danfoss(Model No: SM185S4RC)/ Daikin/Copeland/Emerson/Carrier complete all as specified and directed. |
| 38 | Disconnecting from mainsand Supply & fixingin replacement of scroll compressorfrom theAC plant of Cap23 TR, Installingand testing of company madeScroll Type compressor Model No. SZ380A4CBE Lubricant P.O.E 160 SZsuitable for Refrigerent 407C. Initially charging of Gas 407 and commisioning complete all as specified and directed. |
| 39 | Disconnecting from mains Supply & fixingin replacement of scroll compressorfrom theAC plant of Cap5 TR, Installingand testing of company madeScroll Type compressor Model No. CR72KQM or equiv Lubricant P.O.E 160 SZsuitable for Refrigerent R22. Initially charging of Gas R22 and commisioning complete all as specified and directed. |
| 40 | Disconnecting from mains and Taking out existing unserviceable compressor sealed unit from the split type AC of Cap 8.5 TR and Supply, Installing and testing of company made new compressor of Cap 8.5 TR with 01 year gurantee including cleaning and removing dirt/dust from the cooling coil , condenser coil with necessary modification, cap tube etc. and charging of Gas F-22/R-34 and commosioning complete all as specified and directed. |
| 41 | All as per srl item no. 34.00but split type AC of capacity 5.5 TR. |
| 42 | All as per srl item no. 34.00but split type AC of capacity 3 TR. |
| 43 | Note for Ser Item No. 31.00 to 36.00: (i) The compressor should be installed by the OEM refrigerant mechanic.(ii) After successful installation, the compressor should be vacuum by the nitrogen at desired pressure and leakage test to be carried out.(iii) The rate offirst charge of refrigerant gas in the compressor to be quoted in the rate of compressor by the contractor. |
| 44 | Supply and charging of Refrigerant Gas R-407C in plant after detections/rectification of any leakages in the system using N2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test as specified and directed. |
| 45 | Supply and charging of Refrigerant Gas R-410A in plant after detections/rectification of any leakages in the system using N2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test as specified and directed. |
| 46 | Supply and charging of Refrigerant Gas R-22 in plant after detections/rectification of any leakages in the system using N2 gas and flushing the complete system thoroughly with nitrogen gas including pressure test as specified and directed. |
| 47 | Note for Ser Item No. 37.00 to 39.00 :- (a) Gas to be brought by the contractor at site from the authorised dealer/manufacturer and shall be in company\"s sealed cylinder and empty cylinders shall be returned to the contractor. (b) The unit rate quoted are inclusive of the cost of Nitrogen/CO2 gas used for leakage test and pressure test prior to filling/charging of gas. |
| 48 | Material & labour for laying MS Pipe heavy grade of size 150mm bore with all fittings, welding, testings etc laid in floors or fixed to walls and ceilings etc of sizes including providing two coats of anti corrosive paint over a coat of primers on external surfaces of pipes and complete all as specifed and directed. |
| 49 | Material & labour for laying MS Pipe heavy grade of size 100mm bore with all fittings, welding, testings etc laid in floors or fixed to walls and ceilings etc of sizes including providing two coats of anti corrosive paint over a coat of primers on external surfaces of pipes and complete all as specifed and directed. |
| 50 | Material & labour for laying MS Pipe heavy grade of size 80mm bore with all fittings, welding, testings etc laid in floors or fixed to walls and ceilings etc of sizes including providing two coats of anti corrosive paint over a coat of primers on external surfaces of pipes and complete all as specifed and directed. |
| 51 | Material & labour for laying of GI pipe 50 mm bore medium grade ISI markedwith all fittings complete all as specified and directed. |
| 52 | Material & labour for laying of GI pipe 40 mm bore medium grade ISI markedwith all fittings complete all as specified and directed. |
| 53 | Material & labour for laying of GI pipe 25 mm bore medium grade ISI markedwith all fittings complete all as specified and directed. |
| 54 | Material & labour for laying of GI pipe 20 mm bore medium grade ISI markedwith all fittings complete all as specified and directed. |
| 55 | Supply & fixing in replacementBUTTERFLY VALVE (MANUAL) size 150 mm with CI body SS Disc, insulated, Nitrile Rubber Seal & O Ring PN 16 pressure rating for chilled water/hot heater circulation as specified complete all as specified and directed . Make:- Castle/Zoloto/ Sant/Venus as approved by GE |
| 56 | Supply & fixing in replacementBUTTERFLY VALVE (MANUAL) size 100 mm with CI body SS Disc, insulated, Nitrile Rubber Seal & O Ring PN 16 pressure rating for chilled water/hot water heater circulation including takking down as specified complete all as specified and directed. (Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) |
| 57 | Supply & fixing in replacement BUTTERFLY VALVE (MANUAL) size 80 mm with CI body SS Disc, insulated, Nitrile Rubber Seal & O Ring PN 16 pressure rating for chilled water/hot water heater circulation including takking dow as specified complete all as specified and directed. (Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) |
| 58 | Supply & fixing in replacement BUTTERFLY VALVE (MANUAL) size 50/40 mm with CI body SS Disc, insulated, Nitrile Rubber Seal & O Ring PN 16 pressure rating for chilled water/hot water heater circulation including takking down as specified complete all as specified and directed. (Make:- Castle/Zoloto/ Sant/Venus as approved by GE ) |
| 59 | Supply & fixingin replacement of NON RETURN VALVE of size 150 mm with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation complete all as specified and directed. |
| 60 | Supply & fixingin replacement of NON RETURN VALVE of size 100 mm with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation complete all as specified and directed. |
| 61 | Supply & fixingin replacement of NON RETURN VALVE of size 80 mm with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation complete all as specified and directed. |
| 62 | Supply & fixing in replacement of NON RETURN VALVE of size 50/40 mm with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation complete all as specified and directed. |
| 63 | Supply & fixing in replacement of Y - STRAINER of size 150mm of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation complete all as specified and directed. |
| 64 | Supply & fixing in replacement of Y - STRAINER of size 100mm of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation complete all as specified and directed. |
| 65 | Supply & fixingin replacement of Gun Metal gate valve of size 50 mm dia ISI marked including cutting / threading and welding of existing GI pipe complete all as specified and directed. |
| 66 | Supply & fixingin replacement of Gun Metal gate valve of size 40 mm dia ISI marked including cutting / threading and welding of existing GI pipe complete all as specified and directed. |
| 67 | Supply & fixingin replacement of Gun Metal gate valve of size 25 mm dia ISI marked including cutting / threading and welding of existing GI pipe complete all as specified and directed. |
| 68 | Supply & fixingin replacement of Gun Metal gate valve of size 20 mm dia ISI marked including cutting / threading and welding of existing GI pipecomplete all as specified and directed. |
| 69 | Supply & fixing in replacement outdoor fan motor with fan blade for 3 ton outdoor split AC existing as per ground complete all as specified and directed. |
| 70 | Supply & fixing in replacement condenser coil for 3 Ton outdoor unit existing as per ground complete all as specified and directed. |
| 71 | Supply & fixing in replacement exhaust fan motor with fan blade used for cooling in cold storage size as per existing at ground complete all as specified and directed. |
| 72 | Supply & fixing in replacement of evaporator coil used in cold storage at MH complete all as specified and directed. |
| 73 | Supply & fixing in replacement expansion coil for 3 TR Split type AC/Pillar AC complete all as specified and directed. |
| 74 | Material & labour for Brickwork Cement mortar 1:4 with subclass‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar including demolition of existing brick work complete all as specified and directed. |
| 75 | Material & labour for Brickwork cement mortar 1:4 with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar including demolition of existing brick work complete all as specified and directed. |
| 76 | Material & Labour for 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub basecomplete all as specified & directed |
| 77 | Supply & fixing in replacement ball valve made ofbrass suitable for 23 TR Compressor existing as per ground complete all as specified and directed. |
| 78 | Material & labour for Servicing ofoutdoor unit and indoor equipments and cleaning of duct of ductable type AC Plant of capacity 8.5 TR complete all as specified and directed. |
| 79 | Material & labour for Servicing ofoutdoor unit and indoor equipments and cleaning of duct of ductable type AC Plant of capacity 5.5 TR complete all as specified and directed. |
| 80 | Material & labour for Servicing and cleaning of all portion of Supply Duct and return duct along with strengthning of ducts of Raina Central AC Plant complete all as specified and directed. |
| 81 | Material & labour for Servicing and cleaning of all portion Supply Duct and return duct along with strengthning of ductsof OT Central AC Plant complete all as specified and directed. |
| 82 | Material & labour for Servicing and cleaning of all portion of Supply Duct and return duct along with strengthning of ducts of ICU Central AC Plant complete all as specified and directed. |
| 83 | Material & labour for Servicing and cleaning of all portion of Supply Duct and return duct along with strengthning of ducts of Maternity and Cold storage Central AC Plant complete all as specified and directed. |
| 84 | Disconnecting from mains and Taking out existing unserviceable Blower motorfrom the split type AC of Cap 8.5 TR and Supply, Installing and testing of company made new blow motor with 02 years gurantee including cleaning and removing dirt/dust from the cooling coil , condenser coil with necessary modification complete all as specified and directed. |
| 85 | All as srl iem No. 77 but for split type AC of capacity 5.5 TR. |
| 86 | Supply & fixing in replacement Branch header pipe tie rod setwith flaper complete all as specified and directed. OT plant/ICU. |
| 87 | Material & labour in replacement earthingcomplete with galvanized steel earth plate electrode60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth GI Strip 25x4mm means of bolts, nuts, check nuts and washers of galvanised iron or steel, thimbles and other end of the earth wire connected to DB and protected by galvanised iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No. 3 of MES schedule Pt I of 2009.Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with standgrouted in PCC.(iii) On testing after completion if the desired earth resistanceis more than 2Ώthe earthing will be redone at no extra cost. |
| 88 | Material & labour in replacement for earth continuity conductor 25x4mm galvanised iron strip fix to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe, fix to pole or any other indicated situation or loop earthing etc as required complete all as specified and directed. |
| 89 | Material & labour in replacement of sight/moisture indicator of AC plant as per existing size complete all as specified and directed. make: Danfoss/Syenergy. |
| 90 | Material & labour in replacement for GI sheet metal ducts made of GI sheet of Class-VIII as per IS-277 of 24 SWG galvanised sheet steel thickness for maintenance ofduct in central AC Plant complete all as specified and directed. |
| 91 | Supply & fixingin replacement condenser coil of Split/pillar TypeAC Cap. 3 Ton of existing make and type from any locationcomplete all as specified and directed. |
| 92 | All as per srl item No. 84.00 but for expansion valve. |
| 93 | All as per srl item No. 84.00 but for indoor motor. |
| 94 | All as per srl item No. 84.00 but for outdoor fan motor. |
| 95 | All as per srl item No. 84.00 but for evaporator coil. |
| 96 | Supply & fixing in replacementcondenser coil of Split TypeAC Cap. 8.5 Ton of existing make and type from any location complete all as specified and directed. |
| 97 | All as srl item No. 89.00 but for expansion valve. |
| 98 | All as srl item No. 89.00but for outdoor fan motor. |
| 99 | All as srl item No. 89.00 but forevaporator coil. |
| 100 | Supply & fixingin replacementcondenser coil of Split TypeAC Cap. 5.5 Ton of existing make and type from any location complete all as specified and directed. |
| 101 | All as per srl item No. 93.00 but for expansion valve. |
| 102 | All as per srl item No. 93.00 but for outdoor fan motor |
| 103 | All as per srl item No. 93.00 but forevaporator coil |
| 104 | Servicing and Repair of Star and delta motor terminal connections of motors complete all as specified and directed. |
| 105 | Supply & fixing in replacement of Copper tubing of size 1/2\" for repair of AC Plant complete all as specified and directed. |
| 106 | All as per srl item No. 99.00 but for size of 1/4 \" |
| 107 | All as per srl item No. 99.00 but for size of 3/4 \" |
| 108 | All as per srl item No. 99.00 but for size of 5/8 \" |
| 109 | Supply & fixing in replacement of Flair Nut of all size for Copper pipe as described above complete all as specified and directed. |
| 110 | Supply & fixing in replacementhigh pressure switch (HP switch )up to 260 PSI Noand 190PSI NC including removing of refrigerent in empty cylinder and checking of pressure testing leak testing vaccum the system of 700 micron charging the refrigerent in the system complete all as specified and as directed. Make: Danfoss or equivalent as approved by GE. |
| 111 | Supply & fixing in replacement low pressure switch (lP switch )up to 25 PSI Noand 45PSI NC including removing of refrigerent in empty cylinder and checking of pressure testing leak testing vaccum the system of 700 micron charging the refrigerent in the system complete all as specified and as directed. Make: Danfoss or equivalent as approved by GE. |
| 112 | Supply & fixing in replacement of cooling/heating thermostats(proportional thermostats) for various Air Handlingunits as by replacing old thermostats,per specifications incl al accessories, mountings,wiring between thermostat & unit ,terminations etc, complete in all respect as required and as per specifications complete all as specified and directed. Make: Honeywell or equivalent as approved by GE. |
| 113 | Supply & fixing in replacement of industrial Humidistat for various Air Handlingunits by replcing old unsv humidistat as per specifications incl al accessories, mountings,wiring between humidistat & unit ,terminations etc, completeall as specified and directed. make-honeywell or equivalent as approved by GE. |
| 114 | Supply & fixing in replacement 0.5 HP pump along with pvc tubing flexible pipe used forcleaning the plant of size 20 mm dia and length 20 m complete all as specified and directed. |
| 115 | Cheking and testing of Complete oxygen gas supply line for leakage and rectify the defects by tighting the joint and minor repairs, at OT MH complete all as specified and directed. |
| 116 | Supply & fixing in replacement Manifiold NRV as per existing make & size/type complete all as specified and directed. |
| 117 | Supply & fixing in replacement Oxygen regulator as per existing make & size/type complete all as specified and directed. |
| 118 | Supply & fixing in replacement isolation valve 22 mm with fiting as per existing make & size/type complete all as specified and directed. |
| 119 | Supply & fixing in replacement Alarmline as per existing make & size/type complete all as specified and directed. |
| 120 | Supply & fixing in replacement in silver oxygen manifold flexible tail pipe of length 1 meter size 1/2 inchfor N2O and O2 supply as per existing size complete all as specified and directed. |
| 121 | Material & labour for cement concrete for servicing/making foundation,plinth/ filling concrete PCCtype D2, 1:4:8 using 40 mm graded stone agregate complete all as specified and directed. |
| 122 | Supply & fixing in replacement fire damper with link in each AHU as per existing size complete all as specified and directed. |
| 123 | Supply & fixing in replacement of DOL starter for 3 HP motor complete all as specified and directed. |
| 124 | Supply & fixing in replacement ofcopper armoured cable 3 core of size 10 sqmm complete all as specified and directed. |
| 125 | Supply & fixing in replacement Hand held electric brush cutter having min 1000 RPM, with grass trimmer min 7000 RPM with 1200 W rear motor and assist handle, split shaft with accessories for trimming Power Houses lawns, sub stn surroundings etc. The handles of the cutter must be provided in loop type for easy to operate and move around complete all as specified and directed. Make: Neptune / Green Craft / Moti Garden / Usha |
| 126 | Material & labour in replacement of cable XLPE of size 25 sq mm 3½ core insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed. |
| 127 | Material & labour in replacement of cable XLPE of size 35 sq mm 3½ core insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed. |
| 128 | Material & labour in replacement of cable XLPE of size 50 sq mm 3½ core insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed. |
| 129 | Supply & fixingin replacement of On load change over switch415 V, 4 pole, 250 Amps capacity with sheet steel enclosure used in AC Plant for DG supply incl necessary connection of cables from LT panels to change over switch complete all as specified and directed. |
| 130 | Supply & fixing in replacement of portable high pressure jet pump1800 watt, 7 litre/min flow rate with 8 meter outlet hose pipe incl all fitting and accessories for servicing ofrefrigeration system complete all as specified and directed. |
| 131 | Supply & fixing in replacement set of tools of 5/8 pipe bender, 1/2 pipe bender, gas flame lamp, copper tube cutter, wrench of size 10\" and 14\", flaring tool,swaging tool 125 mm long, plier,clamp meter and screw driver for day to day complaint of AC refrigeartion complete all as specified and directed. |
| 132 | Material & labour for attending day to day complaints pertains to AC plant of any capacity as and when required with skilled Ref-Mech/Electrician and helper, with necessary T&P for checking the equipment at existing location and find out the faults/defects and rectify the defects in situ and cleaning/normal maintenance to the equipments (including Lugs wire phase preventiver, nuts, bolts etc as required on site)complete to make the equipment functional in all respect complete all as specified and directed. Note :(i) Spare parts shall be measured and paid separately except minor items like thimbles/lugs wire etc. |
| 133 | Supply & fixing in replacement Single phase preventer system of supply 415 Volt 50 Hz Model VSP2complete all as specified and directed. Make :-Minilec/ L&T/ABB |
| 134 | Supply & fixing in replacement Auxiliary contactorMNX A-2, for 415 volt 10 Amps for contactor25 Amp complete all as specified and directed. Make:- L&T/ Havells/ Legrand. |
| 135 | Supply & fixing in replacement Contactor MNX 25-40 Amp complete all as specified and directed. Make:- L&T/ Havells/ Legrand. |
| 136 | Supply & fixing in replacement Contactor MNX 50-70 Amp complete all as specified and directed. Make:- L&T/ Havells/ Legrand. |
| 137 | Supply & fixing in replacement Contactor MNX-18 Amp complete all as specified and directed. Make:- L&T/ Havells/ Legrand. |
| 138 | Supply & fixing in replacement Side mounting add-on block with Aux contact 1No+1Nc suitable for MNX- 9 to 40 contactor complete all as specified and directed. Make L&T/ Havells/ Legrand |
| 139 | Supply & fixing in replacement Electronic timers type ET-100,110/240 volt, 50 Hz complete all as specified and directed. Make : MICON or equivalent as approved by GE. |
| 140 | Supply & fixing in replacement Timer GT-200 complete with coilvoltage 220V complete all as specified and directed. Make-BCH/L&T or equivalent as approved by GE. |
| 141 | Supply & fixing in replacement Overload Relay 9 to 14 Amp 3 pole, directly operated complete all as specified and directed. Make-L&T / BCH or equivalent as approved by GE. |
| 142 | Supply & fixing in replacement Overload Relay 20 to 32 Amp 3 pole, directly operated complete all as specified and directed. Make-L&T / BCH or equivalent as approved by GE. |
| 143 | Supply & fixing in replacement Overload Relay 28 to 42 Amp 3 pole, directly operated complete all as specified and directed. Make-L&T / BCH or equivalent as approved by GE. |
| 144 | Supply & fixing in replacement Selector switch 4 way for volt meter complete all as specified and directed. Make – Standard Gold or equivalent as approved by GE. |
| 145 | Supply & fixing in replacement Toggle switch SPST 10 Amps complete all as specified and directed.Make KAYCEEL / L&T or equivalent as approved by GE. |
| 146 | Supply & fixing in replacement Volt meter 0 – 500 V digital type complete all as specified and directed.Make – AE /Crompton Greaves or equivalent as approved by GE. |
| 147 | Supply & fixing in replacement Ammeter0–100Amps digital type complete all as specified and directed. Make - AE/Crompton Greaves or equivalent as approved by GE. |
| 148 | Supply & fixing in replacement MCB 25 Amp to 63 Amp, TP complete all as specified and directed. |
| 149 | Supply & fixing in replacement MCB of rating 16 Amp to 32 Amp, TPN complete all as specified and directed. |
| 150 | Supply & fixing in replacement MCB of rating 40 Amp to 100 Amps, TPN complete all as specified and directed. |
| 151 | Supply & fixing in replacement MCCB, adjustablethermal and adjustable magnetic setting of capacity 250 Amps, 415V, four pole, 36 KA complete all as specified and directed |
| 152 | Supply & fixing in replacement MCCB, adjustablethermal and adjustable magnetic setting of capacity 200 Amps, 415V, four pole, 25 KA complete all as specified and directed |
| 153 | Supply & fixing in replacement MCCB, adjustablethermal and adjustable magnetic setting of capacity 160 Amps, 415V, four pole, 25 KA complete all as specified and directed |
| 154 | Supply & fixing in replacement MCCB, adjustablethermal and adjustable magnetic setting of capacity 125 Amps, 415V, four pole, 16 KA complete all as specified and directed |
| 155 | Supply & fixing in replacement MCCB, adjustablethermal and adjustable magnetic setting of capacity 100 Amps, 415V, four pole, 16 KA complete all as specified and directed |
| 156 | Material & labour for PVC insulated, Armoured, shielded , multistranded copper conductor cable for instrumentation havingsignal capacity of (4-20)mA/24VAC/24VDC of size 1 sq mm 4 core including saddles,& screws with laying in M S conduit light grade of size 25 mm perfectly complete all as specified and directed. |
| 157 | Supply & fixing in replacement XLPE PVC insulated copper armoured cable 25 sqmm 3.5 core complete all as specified and directed. |
| 158 | Supply & Installation in replacement of Analogue Pressure Gauge, Glycerin filled with gauge cock , having following specification:Pressure Gauge;Case & Bazel Ring : SS - 304 Snap action Bayonet type;Bourdon & Movement : SS - 304.Pressure Element : SS - 316.Ambient Temp: 10°C ~ 45°C.Socket : SS - 304.Window : Toughened Glass .Mounting : Bottom Center.Accuracy Class: 1.6 as per EN 837-1. Nominal dia size: 100 mm.Pointer: Not adjustable, Aluminum Black. Gauge Cock. Gauge cock should be in stainless steel with threaded connection suitable for nominal pressure of 16 Bar complete all as specified and directed. Connection size : 1/4\" BSP. Make : Dwyer / Forbes Marshall |
| 159 | Supply & fixing in replacement of Thermometer, case and bezel moc shall be cast aluminum 304, weather proof as per IP - 65. Immersion length around 200 mm, Connection 1/2\" BSP with SS 304 thermowell dully filled with glycerin/ equivalent complete all as specified and directed. Make : General Instrument / H Guru. |
| 160 | Supply & fixing in replacement Automatic Purge Valve MOC shall be of Brass and Plastic Cap shall be provided on the Outlet to shut the air vent when not in use. There shall be check valve at the bottom to seal the system when the Auto Air vent is removed for servicing. Auto Air Vent shall be installed on all High Points in the water piping system to automatically remove the trapped air. 3/8\" BSP suitable for maximum operating pressure at 10 Bar complete all as specified and directed. Make : Anergy or equivalent as approved by GE. |
| 161 | Supply & fixing in replacement water flow switch in repair of model HFS -25 complete all as specified and directed. Make: Synergy, Honeywell or or equivalent as approved by GE. |
| 162 | Supply & fixingin replacement of Expansion Valve with fixed orifice suitable for every type of Refrigeration and Air Conditioning plants of existing makes and complete all as specified and directed. Make: Danfoss or equivalent as approved by GE. |
| 163 | Supply & fixingin replacement Liquid line Filter drier/Drier core Filter as per existing complete all as specified and directed. Model: equivalent or as per existing. Make: Danfoss Cat Part No-DCL-305 or equivalent model as recommended by the Manufacturers. |
| 164 | Supply & fixing in replacement of LWT/EWT (Leaving water temp and Entering water temp) sensors with probe as per the plant capacity along with minimum 6 meter of suitable core of copper cable as per existing size complete all as specified and directed. Make: Danfoss, Invotec, ABB, Indfos. |
| 165 | Supply & fixingin replacement angle valves 1/4\" x1/4\" and complete all as specified and directed. |
| 166 | Supply & fixingin replacement of Crank case heater for Scroll Compressor (8.5 TR to 23 TR) complete all as specified and directed. |
| 167 | Supply & fixing in replacement for Safety Valvecomplete all as specified and directed. |
| 168 | Supply and filling/Top up of Compressor oil, non freezing or as recommended by Blue Star/Voltas in AC plant including vaccum testing complete all as specified and as directed. Notes :-(i) Oil shall be brought by the contractor at Site from authorised dealer/ manufacture company in sealed canes of standard packing with test certificate and purchase Vrs.(ii) Re-fillingshall be done in the presence of Engr-in-charge. |
| 169 | Supply & fixing in replacement triple layer rotational moulded polyethylene water storage tanks of Capacity 2000 liters ISI marked (Cylindrical vertical with closed top) hoisted and fixed in positioncomplete all as specified and as directedMake : Sintax/Plasto/Aashirwad. |
| 170 | Supply & fixingfor Galvanized wire mesh with wire of 1.40 mm dia, mesh size not less than 25 mm fixed on cooling tower by nut/bolts etc incl taking down existing complete all as specified and directed. |
| 171 | Supply & fixing in replacement for PVC float valve assembly 25/20 mm complete all as specified and directed. |
| 172 | Supply & fixing in replacement for PVC Nozzles as per existing complete all as specified and directed. |
| 173 | Material & labour for replacement of Water Hydra/Sprinkler for Cooling tower of cap 15 TR to 50 TR capacity AC Plant byDismantling of cooling tower electric motor and disconnecting all PVC Nozzles from hydra and replacement of the same as perexisting size/model hydra for suitable water flow by pvc nozzles withreplacement of rusted nuts, bolts with washers etccomplete all as specified and directed. |
| 174 | Material & labour for replacement of Water Hydra/Sprinkler for Cooling tower of cap more than 50 TRcapacity AC Plant byDismantling of cooling tower electric motor and disconnecting all PVC Nozzles from hydra and replacement of the same as perexisting size/model hydra for suitable water flow by pvc nozzles withreplacement of rusted nuts, bolts with washers etccomplete all as specified and directed. |
| 175 | Supply & fixing in replacement of multi blade propeller Fan of cooling tower having capacity of 15TR to 50 TR . Thefan blade construction MOC should be aluminium alloy/FRP as per existing at site complete all as specified and directed. Note: Sample shall be taken from site. |
| 176 | Supply & fixing in replacement of Drift eliminator of cooling tower having capacity of 50 TR to 75 TR as per existing at site complete all as specified and directed. |
| 177 | Material & labour for replacement of PVC Fill blocks of size 600mm X 300mm X 150mm complete all as specified and directed. |
| 178 | Supply & fixingin replacement of Electric Strip Heaters3 KW capacity ISI marked complete all as specified and directed. |
| 179 | Supply & fixingin replacement of Electric Strip Heaters2 KW capacity ISI marked complete all as specified and directed. |
| 180 | Material & labour in Replacement to Suction/Discharge valve of Teflon sheet ‘O’ ring etc complete all as specified and directed. |
| 181 | Material & labour for providing Thermal Insulation in replacement of old worn out insulation to supply air ducts /return air ducts with 13 mm thick , EPDM rubber with factory laminated glass cloth 7mil , 200 GSM sheet, Use adhesive fevicol SR 998, Joint should be sealed withtape of at least2\" wide (Standard type ) and finished withCoating of Fevicol AC Duct king lag coating AF: 5590 and finally finish with UV resistance paint as per client choice complete all as specified and directed. Make of EDPM rubber is Aeroflex and Make of Adhesive and lag coating is Fevicol. |
| 182 | Supply & fixing in replacement ofPin up Display Board of wooden of size 2X3 feet made of engineered wood and oak finished frame, fasten to the walls securely and simply with heavy duty factory installed mounting system alongwith 50 pins complete to pin-up the Fire safety orders, SOP, Standing orders for the AC plants complete all as specified and directed. |
| 183 | Supply & fixing in replacement of Centrifugal pump with 7.5 HP electric motor, Bronze/SS impeller, GM bushes, stuffing box and making all connection with existing condensor and chiller system complete with all accessories/pipe fittings and making connections to starter complete all as specified and directed. |
| 184 | Supply & fixing in replacement of Centrifugal pump with 5 HP electric motor 3 phase 415 V, IE3 and making all connection with existing condesor and chiller system complete with all accessories/pipe fittings includingtaking down of existing and making connections to starter complete all as specified and directed. |
| 185 | Supply & fixing in replacement of monoblock /centrifugal pump with 3 HP elecric motor ,3 phase 415 V, IE3 and making all connection with existing condesor and chiller system complete with all accessories/pipe fittings includingtaking down of existing and making connections to starter complete all as specified and directed. |
| 186 | Supply & fixing in replacement of garden LED 8W bollard lightsmade in 3 parts (a) Spun aluminiumdome shaped top cover (b) Cylindrical opal acrylic diffuser (c ) GI pipe bottom housing the control gear for 8/9 W LEDs, Maintenance done by removing die cast aluminium housing, warm white luminaire,luminaire is wired with inbuilt driver with 4.5kV surge protection,Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal, Finish in graphite grey powder coated IP6 complete all as specified and directed. |
| 187 | Supply & fixing in replacementblower fan motor double shaft 1/8 HP ,93 W, 230 Volts with blower used in supply air duct in Raina Auditorium complete all as specified and directed. |
| 188 | Supply & fixing in replacement ofElectrical insulating rubber mat of size ( 2 mtr X 1 mtr X 3 mm ) tested for LT voltage 1100 volts complete all as specified and directed . |
| 189 | Material & labourfor Spray painting to Central AC Plant completecomprisingof compressors, motors, condensor,cooling tower and cooling tower pumps,pump / monoblocks, MS / GI pipe lines of sizes etc after preparation of old painted surface as per colour code includingand marking arrow, SM/ MES Nos, colour for 11 to 100 TR ACs plantcomplete all as specified and directed . |
| 190 | Supply & fixingfor V-Belt of size A-50/54/65/81, B-47/56/59/70/72/75/76/78/80/82/90/94/101/102/103, C-107complete all as specified and directed. Make- Fenn or equivalent as approved by GE. |
| 191 | Supply & fixing in replacement of old u/s Outdoor fan of Package type AC plant of capacity 10 TR, suitable for Plant of The MOC of the fan blade shall be FRP type complete all as specified and directed. Make-Bluestar, Model No-DPA1441R3-I. |
| 192 | Supply, fixing, testing and installation ofDuct mounted Temperature and RH transmitter with digital display including taking down existing complete all as specified and directed. Make: Invotec/Honeywell/Danfoss. |
| 193 | Supply & fixing in replacement of Aluminium Grill/diffuser for AC Plant of size as per ground complete all as specified and directed. |
| 194 | Material & labour for writing SM/MES No. with suitable Paint/color (as approved by Engr in Charge) on the AC (window/Split type), Coolers/Desert coolers, Water Coolers etc in possession of MES complete all as specified and directed. Note: Contractor shall deploy his painter who will approach the user with the permission of dept and shall write SM/MES No. and quoted rate must include the cost of visit of deployed painter to user. |
| 195 | Supply & fixing in replacement of balancing valve of size 80 mm with built in flow measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation complete all as specified and directed. |
| 196 | Supply & fixing in replacement of balancing valve of size 50 mm with built in flow measuring facility with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation complete all as specified and directed. |
| 197 | Supply & fixing in replacement HP/LP pressure cut out switch complete all as specified and directed.Make : Indfoss/Honeywell/Daspass. |
| 198 | Note:-Amount of credit ofRs. 190722.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail