| 1 | Earthwork in excavation of foundation & plinth in hardsoil including rough dressing levelling the bed and depositing the excavated soil within initial lead of 50mtr & lift of 1.5mtr etc as per direction of Engineer-in charge |
| 2 | Filling foundation and plinth with sand well watered and rammed etc. |
| 3 | Cement Concrete (1:4:8) using 4cm size H.G.C.B. metal including cost ,carriage ,royality &curing etc. complete. |
| 4 | Cement Concrete (1:2:4) using12cm size H.G.C.B. Chips(both RCC & plan C.C) including cost ,carriage ,royality &curing etc. complete. |
| 5 | Fly Ash Brick masonry in CM (1:6) in F & P including cost ,carriage ,royality &curing etc. complete |
| 6 | Fly Ash Brick masonry in CM (1:6) in superstructureincluding cost ,carriage ,royality &curing etc. complete |
| 7 | 2.5CM A.S.flooring with (1:2:4) using 12mm size chips including cost,carriage,royality & curing etc.complete |
| 8 | (a) Grade beam/Column/plinth Bend (Rigid smooth ,centering & shuttering) |
| 9 | (b) Lintel(Rigid smooth ,centering & shuttering) |
| 10 | (c ) Slab/Chajja(Rigid smooth ,centering & shuttering) |
| 11 | (d) Piller (Rigid smooth ,centering & shuttering) |
| 12 | Supply fitting & placing of on coated HYSD bar (M.S.Rod) including carriage, cutting, bending, binding & tying the grills and placing in position including cost of binding wire 18 to 20 guage etc.complete |
| 13 | Dry brick khoawell watered and rammed to 10CM in flooring including cost,convence royality etc.complete |
| 14 | 2.5cm DPC with C.C. (1:2:4) using 12mm size H.G. chips including cost,convence royality & curing etc.complete |
| 15 | 12mm thick cement plaster in C,M (1:6) over brick massonary including cost convence roylaity & curring etc. complete. |
| 16 | 4CM thick grading plastering in CC(1:2:4)using 4.7mm size HGCB chips |
| 17 | Cement punning over plastering |
| 18 | Cement washing one coat over plastering |
| 19 | White washing two coat water Proofing cement paint inside the room. |
| 20 | Colour washing two coat with shell lime and colouring materials |
| 21 | Priming two coat with approved primer |
| 22 | Painting two coats with approved paint over a coat of primer |
| 23 | Filling foundation and plinth with exacavated materials |
| 24 | Labour charges for jointing and laying the pipe line including testing then after the leak proof and manual carriage of 160 mm diaHDPE pipe in all respect etc.& complete. |
| 25 | Fitting of starter,mainswitch,Kitkat,rotary swaitch in the pannel box and fixing the pannel box and the pannel foundation connecting tropodure cable with main supply line and S/S cable with S/S Pumpset including transportation of materials to the work site etc.complete including Pump Chamber Wiring. |
| 26 | Making earthing with required earthing materials like Charcoal,Common salt,Conduit pipe,Soft solder,Alcape,Nuts & Bolts,Cable sockets etc.including excavation of earth pits of size (1.20m x1.20m x3.0m ) for fixing of earthing pipes of size 37.5 mm dia x 3.00M length with required slottings in pipe and fitting with 37.5 mm dia G.I.Flange including excavation of earthing trench for laying of earthing G.I.Wire and filling the trench & pit after fixing of pipes on completion of earthing works incluing supply of all the materials,including transportation etc.complete as per the direction of the site Engineer in charge. |
| 27 | Installation of 10 HP S/S pumpset by lowering inside the T.W. & fitting with the 100mm dia G.I.Pipe length 25 mtr including cutting,threading of pipes & clamping over the support pillars by T.W clamp & connecting it with the distribution PVC pipe line laid in under ground including fitting of bends,flanges,sockets,valves & special joints as required with Nuts, Bolts, Rubber insuration etc.including transportation of materials,complete as per the direction of the site Engineer in charge. |
| 28 | Labour charges for fitting fixing of M.S.Door,Windowshutter |
| 29 | Writing for culture nameof Project Data for transperency of P.P. |
| 30 | Fitting of PVC shadle,Air release valve etc |
| 31 | Earth work in excavation in hard soil including dressing and breaking clods and laying in layer not exceeding 0.30 mtr depth |
| 32 | 10 H.P./7.5 K.W. Submmerssible Pump set coupled with totally enclosed Water cooled squirrel cage induction motor with delivery discharge 900 LPM at 25 mtrs. Head with cable, cable clip, support clamp etc. suitable for operation at 415+6% ,-15% volt,3 phase ,50 Hz, AC power supplyas per the particular mentioned in \"\"Annexure-\"\"A\"\" enclosed with ISI mark.. |
| 33 | Control Pannel board with Auto Star-delta Starter of sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 15 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil suitable for operation at voltage range of 350 - 440 V. and to provide dependable protection during over load and single phasing as per particular mentioned in \"\"Annexure-\"\"B\"\" with ISI mark. |
| 34 | 3 core x10mm PVC insulated (HD) armoured Electric Cable with Allumunium conductor for use in 3 phase power system of working voltage upto and including 1100 Volts at 50 Hz confirming to IS 1554 (Pt-5) / 1988 with ISI mark. |
| 35 | Tool Box |
| 36 | 4mm PVC insulated Copper wire with ISI mark |
| 37 | 63 Amp Porceline Kit kat Fuse 415 volt with ISI mark |
| 38 | 63 Amp 415 Volt T.P.Main Switch confirming to IS 4064(pt-I & pt-II) with utilisation category AC-22 with ISI mark and as approved by NESCO |
| 39 | 2.5 MM² dia 3 core submersible flat cable of ISI |
| 40 | M.S Wall base frame with teel cover plate |
| 41 | M.S.T.W clamp for clamping 100mm dia G.I.Pipe made out of M.S.Flat of size 10mm x 75mm of length 58 Cm of each with both side limbs of 20 Cm length having 2 Nos 5/8\"\" dia holes in each lim at both side. |
| 42 | 100mm dia nominal bore G.I.Pipe having wall thickness 4.5mm electrical resistance welded of medium class conforming to IS - 1239 (part-I/2004) with latest Amendments,screwed at both ends as per IS -554 with socketed at one end and the other end protected with plastic threaded protector The socket conforming to IS:1239 (Part-II/1992) with latest Amendment with in random length of 4 to 7 mtrs.should bear ISI Certification and manufacturers name/trademark . . . |
| 43 | 100mm dia G.I.Bend confirming to IS No.1239 (pt-II/1992) |
| 44 | 100mm dia G.I.Socket confirming to IS No.1239 (pt-II/1992) |
| 45 | 100mm dia Screw Boss Flange confirming to IS No.6392/1971 |
| 46 | 100mm dia C.I.Sluice valve confirming to IS-14846/2000,Part-1 with ISI mark ,hand wheel,G.M.fitting,Brass spindle,s/s 410 Spindle |
| 47 | 100 MM dia N.R.Valve |
| 48 | 50mm C.I.Air release valve with shadle & fitting materials |
| 49 | Cost of 160mm dia C.I. Buterfly Valve BS:5155/15: Kirloskar of equivalent make including all cost conveyance, cess etc. |
| 50 | 5/8\"\" x 3\"\"M.S.Full threaded Nut Bolt(Heavy Duty) |
| 51 | 1/2\"\" x3\"\" M.S.Full threaded Nut Bolt (Heavy Duty) |
| 52 | 3mm (1/8\"\") thick Rubber Insertion |
| 53 | 160mm dia HDPE Tail piece |
| 54 | Supply of High Density polythelene (160mm dia HDPE Pipe) (PE 80 - PN 4) for water supply as per IS 4984/2016, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & Post inspection, cess etc. complete. |
| 55 | 160mm dia HDPE End cap |
| 56 | Cost of 160mmx160mmx110mm GI Riser Tee with accessories |
| 57 | 160x110mm dia HDPE Reducing Socket. |
| 58 | Cost of 160mm dia Slipon Flange |
| 59 | Cost 160mmx160mmx160mm HDPE Tee spigot design 6 Kg. |
| 60 | Cost of 200 x100mm dia T.W.Cap |
| 61 | Cost of T.W.safe guard including labour charges |
| 62 | Cost of M.S.Door shutter & window shutter with grill including M.S.frame |
| 63 | Cost of Primer |
| 64 | Cost of paint |
| 65 | Drilling a perfect vertical bore of 450mm dia 0 mtr to 30 mtr. |
| 66 | Drilling a perfect vertical bore of 450mm dia 31 mtr to 60 mtr. |
| 67 | Drilling a perfect vertical bore of 450mm dia 61 mtr to 90 mtr. |
| 68 | Cost of 200mm dia PVC casing pipe ASTM Confirming to ISI(Sch.80) |
| 69 | Labour charges for making strainer pipe out of total casing pipe including loading,unloading & Transportation. |
| 70 | Cost of 200mm dia PVC Well cap |
| 71 | Cost of 200mm dia PVC Cone |
| 72 | Cost of 200mm dia PVC Nipple |
| 73 | LOWERING OF 200 mm diaASTM Pipe. |
| 74 | LABOUR CHARGES FOR EXCAVATION OF MUD PIT & CHANNEL SILTING PIT & REFILLING THE PIT |
| 75 | LABOUR CHARGES FOR LOADING ,UNLOADING OF CAMP MATERIALS INCLUDING TRANSPORTATION CHARGES. |
| 76 | Labour charges for site clearance & Rig levelling & const. of aapoach road. |
| 77 | COST OF COIR ROPE,COTTON WASTE |
| 78 | CLEANING AND DEVELOPING THE T/W WITH AIR COMPRESSOR CONTINEOUSLY TILL ADEQUATE DISCHARGE OF CLEAR AND SAND FREE WATER 0 TO 90 MTR. |
| 79 | OPERATION OF 5HP WATER PUMP |
| 80 | COST OF BENTONITE DRILLING MUD |
| 81 | COST OF GRAVEL INCLUDING TRANSPORTATION |
| 82 | Construction of 3-phase 11KV line as per REC standard confirming to RE Rules 1956, with 9 meter long PSC pole support in 50 meter span, 80 sq. mm A.A.A. conductor, 11 kv \"V\" Cross-arm, required Stay-set at bending point and double stay at end point with 18 mm G.I.H.T. Stay, with required numbers of 11 kv B&S Disk insulator(70KN)(Double Disc) and 11 kv Pin-Insulator, providing Coil earthing at each pole, Carping and Padding of Poles, Danger Board at each Pole with Anti-Climbing device etc. including cost of all labours, inspection and commissioning & writing on the Pole as per prescibed colour code, 400Amp AB Switch,. complete as per the direction of the site engineer in charge. |
| 83 | Interposing pole |
| 84 | Birbed fencing(size 15\" x 10\" ) with construction of Fly Ash brick boundary wall,Sand filling and metal spreading,Fixing of Iron Grill gate with locking arrangement etc. |
| 85 | Construction and erection of 11/0.416 KV 25 KVA Star rated DP Sub-Station confirming to RE Rule 1956. Mounted on 2.44 mt. longstructure, supportedon 9 mt long PSC pole, |
| 86 | Cut Point |