| 1 | Recharge Shaft |
| 2 | Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200mm dia |
| 3 | Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 150mm dia |
| 4 | Supply of ERW M.S. black casing pipe ISI marked(IS:4270/1992) of grade Fe410 of following sizes at site of work: 200 mm Nominal bore of pipe |
| 5 | Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985: 200 mm Nominal Bore. |
| 6 | S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size: 200mm dia |
| 7 | Supply & lowering air line of 25mm dia, G.I. pipe \"B\" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. |
| 8 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids: Size 3 to 5 mm |
| 9 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids: Size 9 to 12 mm |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kinds of soil |
| 11 | Centering and Shuttering with plywood or steel sheetsincluding strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 12 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : 4.10.1 Walls (any thickness) including attached pilasters, buttressesplinthandstring course |
| 13 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 14 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix |
| 15 | Providing and fabricating reinforcement for R.C.C. workincluding straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level : Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 16 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. |
| 17 | Add extra for providing richer mixes respectively at all floor levels |
| 18 | Providing M-25 grade concrete by using cement as per codal provision instead ofM-20 grade design mix. |
| 19 | Providing, hoisting and fixing up to floor five level precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia Mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 : 3 (1 cement : 3 fine sand ) etc complete as per approved design excluding plastering of jambs, sills and soffits : 50mm thick |
| 20 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 21 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 22 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 23 | lnstallation of sign boards having the posts like mandantory, cautionary and informatory boards including excavation, fixing of posts in 300 mm dia. RCC hume pipe-(lS marked) 1.20 m long, 75 cm embedded in ground, the in side of pipe shall be filled with cement concrete 1 : 4 : B with semi-circular hump at top, the pipe shall be painted white with enamel paint including transportation etc. complete : For double post |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 25 | Lettering with black Japan paint of approved brand and manufacture. |
| 26 | P & F 60 cm. wide M.S. ladder in open well made of flat iron 32×5mm and 10mm dia bars @ 200mm c/c with angle iron hold fasts at suitable interval complete as per drawing. |
| 27 | Brass Lock |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :: Two or more coats on new work |
| 29 | Providing and fixing Unplasticized Poly Vinyl Choride ( UPVC ) SWR Pipes Type B for sciland waste discharge system ( IS : 13592 1992 Marked ) of approved quality / make : 110 mm dia . |
| 30 | Providing and fixing Unplasticized Poly Vinyl Choride ( UPVC ) SWR Pipes fitting Type B for sciland waste discharge system ( IS : 13592 1992 Marked ) of approved quality / make |
| 31 | bend 87.5 Deg 110 mm |
| 32 | single tee 110 mm |
| 33 | coupler110 mm |
| 34 | Pipe clips 110 mm |
| 35 | Suplying and fixing fixed wire gauge of 14 mesh X 24 gauge to the metal frame of rolled section by metal biding 20 X 3mm with suitable screw at not exeeding 150 mm distance |
| 36 | Brick masonry in foundation and plinth with bricks of class designation 75 in cement morter 1 : 4 ( 1 - cement : 4 coarse sand ) |
| 37 | Plaster on new surface on wall in cement sand mortar 1 : 4 including racking of joints etc complete fine finish 20mm thick |
| 38 | Providing and fixing T - iron frames for doors windows and ventilators of mild steel Tee sections , joint mitred and welded with 15X3 mm lugs 10 cm long embedded in cement concrete blocks 15X10X10 cm of 1 : 3 : 6 ( 1 cement : 3coase sand 6graded stone aggregate 20mm nominal size ) or with wooden plugs and screw or rawl plugs and screw of with fixing clips or with bolts and nuts as required including fixing of neccesary butt hinges and screw and applying a priming coat of approved steel primer |
| 39 | Tanka |
| 40 | Earth work in excavation by mechanical means ( Hydraulic Excavator / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms , ift upto 1.5 m . including taking out the excavated soll and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter . All kinds of soils |
| 41 | Ordinary rocks |
| 42 | Hard rock ( blasting prohibited ) |
| 43 | Providing and laying in position cement concrete including curing , compaction etc. complete in specified grade excluding the cost of centering and shuttering All work up to plinth level.M10 grade Nominal Mix 1 : 3 : 6 ( 1 cement : 3 coarse sand 6 graded stone aggregate 40mm nominal size ) . |
| 44 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing , compaction , finishing with rendering in cement sand mortar 1 : 3 ( 1 cement 3 coarse sand ) and making good the joints and cost of plastizers ( if required ) excluding the cost of centering , shuttering and reinforcement for Beams , suspended floors , roofs , griders having slopes up to 15 landings , balconies , shelves , chajjas , lintels , bands , plain windows sills , staircases and spiral staircases etc. Providing M 25 grade concrete Base |
| 45 | Providing and laying in position specified grace of cement concrate for RCC structural elements upto floor five level including curing , compaction , finishing with rendering in cement sand mortar 13 ( 1 cement : 3 coarse sand ) and making good the joints and cost of plastizers ( if required ) excluding the cost of centering , shuttering and reinforcement for Walls ( any thickness ) including attached pilasters , buttresses , plinth and string courses , files , columns , pillars , piers , abutments , posts and struts etc. Providing M - 25 grade concrete- Vertical wall |
| 46 | Reinforced cement concrete work in beams , suspended floors , roofs , girders having slopes up to 150 , landings , balconies , shelves , chajjas , lintels , bands , plain windows sills , staircases and spiral staircases , up to floor three level including curing . compaction , finishing with rendering in cement sand mortar 1 : 3 ( 1 - Cement : 3 - coarse sand ) and making good and joints excluding the cost of centering , shuttering and reinforcement : 1 : 1 : 2 ( 1 - Cement : 1 - coarse sand : 2 - graded stone aggregate 20 mm nominal size )-Roof |
| 47 | Grading roof for water proofing treatment with water proffing compound . With Cement mortar 1 : 3 ( 1 cement : 3 coarse sand ) |
| 48 | centrning & shuttering with plywood or steel sheets including strutting , propping bracing both ways with steel props and removal of formwork for upto floor five level for : Walls ( any thickness ) including attached pilasters , buttresses plinth and string course . |
| 49 | Add extra for shuttering in circular work ( in respective centering and shuttering items ) 20 % |
| 50 | Providing and Fabricating steel reinforcement for RCC works including cutting , straightening , bending , placing in position and binding complete including cost of binding wires in foundation & super structures up to 4.5m height above plinth level hot rolled deformed ( IS1139 ) |
| 51 | Providing and fixing MS . sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings , as per direction of Engg incharge but excluding cost of chowkhats : including two coats of anit - corrosive red oxide primer paint . |
| 52 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding New work ( Two or more coats applied @ 3.84 kg / 10 sqm ) . |
| 53 | Providing and Fixing Unplasticized Poly Vinyl Chloride ( UPVC ) SWR Pipes Type B for sciland waste discharge system ( IS 13592 1992 Marked ) of approved quality / make ( 110 mm dia ) |
| 54 | Providing , fixing Fullway PVC valves for discharge of first rain water into drain and then taking water in to Tanka . 110mm |
| 55 | Supplying of Incia mark II hand pump set complete markedwith cylinder and connecting rods etc. IS 1239 with 32 mm pipe 3mtr length |
| 56 | Supply and charging of filter media ( Gravel ) as per department PHED specification including screaming , washing with 5 % HCL solution to make Graval ( Size 4 to 6mm , 8 to 12mm , 10 to 20mm Hard Coarso gnt from approved quarry ) free from silt , day and other all impurities work to be executed as per scope of work 1xed by the department at the time of tendering ( for SSF ) |
| 57 | Brick masonry in foundation and plinth with bricks of class designation 75 in cement morter 1 : 4 ( 1 - cement : 4 coarse sand |
| 58 | Plaster on new surface on wall in cement sand mortar 1 : 4 including racking of joints etc complete fine finish 20mm thick |
| 59 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1 : ralthal , stone kharanja , lime terracing 90mm average thickness ( asper Jaipur Practice with ceiling pointing in cement sand mortar 1 : 3 Complete as per specification for span upto 2.00 mtr |
| 60 | Providing and fixing T iron frames for doors windows and ventilators of mild steel Tee sections , joint mitred and welded with 15X3 mm lugs 10 cm long embedded in cement concrete blocks 15X10X10 cm of 1 : 3 : 6 ( 1 cement : 3coase sand Ggraded stone aggregate 20mm nominal size ) or with wooden plugs and screw or rawl plugs and screw of with fixing clips or with bolts and nuts as required including fixing of neccesary butt hinges and screw and applying a priming coat of approved steel |
| 61 | Providing and Fixing Unplasticized Poly Vinyl Chloride ( UPVC ) SWR Pipes fittings type B for sciland waste discharge system OS 13592 1992 Marked ) of approved quality / makeSingle Tee ( 110 mm ) |
| 62 | Bend ( 110 mm ) |
| 63 | Vent covel 110 mm |