Agriculture Government Departments Closing in 0 days TDR #47910591

Tender For Repair And Maintenance Of Electrical Work In 2 No Type-I Residences At Fisheries Complex Dada Siba,Distt Kangra (Hp)

Issued by Government Departments · kangra, Himachal Pradesh
Tender Value
1.78 Lakhs
Estimated cost
Bid Submission
01 Mar 2025
0 days left
EMD
3600
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maintenance Of Electrical Work In 2 No Type-I Residences At Fisheries Complex Dada Siba,Distt Kangra (Hp)

BOQ

Name of Work: Repair and maintenance of electrical work in 2 No Type-I Residencesat Fisheries Complex Dada Siba,Distt Kangra (HP)
Sl. No. Item Description
1Repair and maintenance of electrical work in 2 No Type-I Residencesat Fisheries Complex Dada Siba,Distt Kangra (HP)
2Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-C
3Supplying and fixing G.I. Modular box 3 Module with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections etc. as required.
4Supplying and fixing G.I. Modular box ofsize 3 Module with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
5Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5 amp switch
6Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus).5amp Socket
7Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make:-Legrand(Myrius),L&T(entice),Anchor(Roma Plus). Bell Push Modular
8Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x1.5 Sq. mm + 1X1.5 sq.mm
9Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x4 Sq. mm + 1X4 sq.mm
10Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 4x4 Sq. mm.+ 2X4 sq.mm
11Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x10Sq. mm.+ 1X6 sq.mm
12Providing, installationtesting and commissioning of ceiling fan with regulator including wiring the down rods of standard length (up to 30cm) and 16/0.20mm twin twisted flexiblecotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required including carriage of material within all leads and lifts. ( Usha technics,Crompten,Havells H S Velocity make or its equivalent. ) or as approved by the Engineer-in-Charge.1200 mm sweep
13Providing and installation exhaust fan of300mm (Metal body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:Make:- Usha,Bajaj,Crompton or its equivalent as approved by Er-in-charge
14Supplying and Fixing LED Battan 36 watt High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL22-511-XXX-65-G1 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent.
15Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
16Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
17Supplying and fixing 5 amps to 32 amps , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Hager,ABB or its equivalent as per best satisfaction of Engineer-in -charge. Single pole
18Supplyinganderection of 40/50/63 amps, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Hager,ABBor its equivalent as approved by Engineer-in -charge.
19Providing and installationof LED Street light 30W with bracket power coated pressure die cast aluminium high power led with heat resistant toughened glass with lens ,electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required.:Make ,wipro(LR26-371-XXX-65-XX),Panasonioc Philips or its equivalent as approved by Engineer-in -charge.( Five year warranty)
20Earthing with G.I earth pipe 4.5 mtr. long and 40 mm. dia, including accessories andproviding masonary enclosure with cover plate having locking arrengement and watering pipe etc. (but without charcoal or coke and salt) complete as required
21Extra for using salt and charcoal for pipe earth electrode completeas required .

AI Tender Summary

OUR REF NO 47910591
AUTHORITY Government Departments
TENDER VALUE 1.78 Lakhs
LAST DATE 01-03-2025
Authority
Authority Name Himachal Pradesh Aquaculture Fisheries and Marketing Society
Work Description Repair And Maintenance Of Electrical Work In 2 No Type-I Residences At Fisheries Complex Dada Siba,Distt Kangra (Hp)
Basic Detail
Tender No 2025_HPAFMS_1894_1
Bidding Type Tender
Location
City kangra
State Himachal Pradesh
Key Dates
Publish Date 22 Feb 2025
Submission Date 01 Mar 2025
Open Date 01 Mar 2025
Finance
Tender Value 1.78 Lakhs
Tender Fee 350
EMD 3600
Exemption Not Available
Document List
e0bbf139-f9ba-451e-b325-3279cb33421e.html
BOQ_147968.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 22, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 01, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 01, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e0bbf139-f9ba-451e-b325-3279cb33421e.html

xls

BOQ_147968.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders