E Tender No Resagging Of Unbunch Ht Ab Cable And Replacement Of Damaged Ht Ab Cable To 11 Kv Aaac Conductor (Al-59) In 11 Kv Poorvi Feeder In Edsd Jaspur Ii And Supply Of Its Associated Decentralized Material Under Electricity Distribution Division Jaspur
Tender Overview
Project Description
E Tender No Resagging Of Unbunch Ht Ab Cable And Replacement Of Damaged Ht Ab Cable To 11 Kv Aaac Conductor (Al-59) In 11 Kv Poorvi Feeder In Edsd Jaspur Ii And Supply Of Its Associated Decentralized Material Under Electricity Distribution Division Jaspur.
BOQ
| Sl. No. | Item Description |
| 1 | Supply Item |
| 2 | Supply of Holding Clamp for SP-55 with N/B(As per Specification of RESPO & UPCL) |
| 3 | Supply of Bracing Clamp for SP-55 with N/B(As per Specification of RESPO & UPCL) |
| 4 | Supply of Nut & Bolts(As per Specification of RESPO & UPCL) |
| 5 | Supply of HOLDING CLAMP FOR PCC POLE(As per Specification of RESPO & UPCL) |
| 6 | Supply of E- CLAMP(As per Specification of RESPO & UPCL) |
| 7 | Supply of PP & CLAMP WITH N&B ST POLE SP-55(As per Specification of RESPO & UPCL) |
| 8 | Supply of Bracing Clamp With N&B for Pcc Pole(As per Specification of RESPO & UPCL) |
| 9 | Supply of DANGER BOARD(As per Specification of RESPO & UPCL) |
| 10 | Supply of PG Clamp Dog to Dog(As per Specification of RESPO & UPCL) |
| 11 | Supply of Earth Wire Clamp Off Size(As per Specification of RESPO & UPCL) |
| 12 | Supply of Stay Clamp With N&B(As per Specification of RESPO & UPCL) |
| 13 | Supply of 11 KV CABLE TIES FOR PIN INSULATOR(As per GTP & Specification of UPCL) |
| 14 | Supply of 11 KV IPC FOR COVERED TOCOVERED COND.(As per GTP & Specification of UPCL) |
| 15 | Supply of 11 KV IPC FOR COVERED TO BARECONDUCTOR(As per GTP & Specification of UPCL) |
| 16 | Supply of 11KV AAAC AL-59 , 99 SQ.MM COVERED COND(As per GTP & Specification of UPCL) |
| 17 | Supply of 11 KV H/S JOINTING KIT 120 SQ MM (O/D)(As per GTP & Specification of UPCL) |
| 18 | Supply of 120 SQ MM Straight through For HT AB Cable(As per GTP & Specification of UPCL) |
| 19 | Supply of BARBED WIRE |
| 20 | Supply of PVC Tape Roll |
| 21 | Supply of HT Tape |
| 22 | Supply of 11 KV TENSION CLAMP WITH BAIL & IPC(As per GTP & Specification of UPCL) |
| 23 | 11 KV AAAC Conductor Work |
| 24 | Cartage of the following material by private truck from store centreto work site dump store approx. distance 0 to 20 Km. including loading into truck and unloading at work site. Dump store and carriage from dump store to pit site. |
| 25 | PCC Pole |
| 26 | STP SP-55 Pole |
| 27 | Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends. |
| 28 | Head Load Cartage of following material road to work site approx. distance 0 to 1 Km. including loading and unloading. |
| 29 | PCC Pole |
| 30 | STP SP-55 Pole |
| 31 | Headload cartage of Small material from road to site |
| 32 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 33 | Erection ofSingle PCC polein proper level and alignment alongwith fixing of all accessories, like top channel & clampsas per RESSPO construction Manual. |
| 34 | Erection ofSingle STP SP-55 polein proper level and alignment alongwith fixing of all accessories, like top channel & clampsas per RESSPO construction Manual. |
| 35 | Erection ofDouble PCC pole in proper level and alignment alongwith fixing of all accessories, like top channel,X-bracing & clampsas per RESSPO construction Manual. |
| 36 | Erection ofDouble STP SP-55 pole in proper level and alignment alongwith fixing of all accessories, like top channel,X-bracing & clampsas per RESSPO construction Manual. |
| 37 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement :4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand andstone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO construction Manual. |
| 38 | Muffing of poles size 0.45 cm x 0.60 cm radious with cc 1:3:6(1 cement :3 coarse sand :6 graded stone 10mm nominal size) blocksize 45cm height from ground level including cost of cement, stone and sand etc. |
| 39 | Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the helpof G.I. wire as per construction manual. |
| 40 | Fabrication of M.S. Channel Angle iron after cutting in requiredsizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing. |
| 41 | Excavation of earth for Stay pit of size 0.6x0.6x1.2mtrin all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 42 | Fixing , tightening and nozzaling of 11 KV Stay with pole and stay rod on required tension as per drawing / RESSPO manual. |
| 43 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement :4 graded stone 20mm nominal size: 8 coarse sand ) block including cost of Cement,sand andstone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual. |
| 44 | Making of section pole for existing HT line complete in all respect. |
| 45 | Fixing of 11 KV XLPE Jointing Kit |
| 46 | Fixing of 11 KV XLPE Straight Through |
| 47 | Fixing of Danger Board and number plate complete by providing clamps of M.S. Flat 50x6 mm and Nuts & Bolts, danger Boards of M.S. Sheet 2 mm Thick 11\"\"x7\"\" size. |
| 48 | Maintenance of DTR |
| 49 | Dismantling and Relaying of 11 KV AB Cable |
| 50 | Resagging the 11 KV AB Cable spiliting 3PH |
| 51 | FIXING OF 11KV 90KN TENSION CLAMPB&IPC |
| 52 | FIXING OF 11KV IPC FOR COVERED -COVERED |
| 53 | FIXING OF 11KV IPC COVERED TOBARE COND. |
| 54 | Straightening of tilted PCC / ST Poles complete as per RESPO drawing. |
| 55 | Renozzeling of Existing Stay Set |
| 56 | Laying , Spreading and Stringing AAAC Conductor |
| 57 | Fixing of 11 KV CABLE TIES FOR PIN INSULATOR |
| 58 | Route cleareance by cutting of tree branches / proning, loping and chopping of trees for 11 KV line. |
| 59 | Chemical Earthingincluding digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor as per drawing No. A) as drawing B, connecting the same with G.I.Strip (to be supplied by contractor ) of size 35x6 mm as per drawing C for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than 1 Ohm. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender