Tender For Petty Miscellaneous Repair Works Including Plumbing & Sanitary Works At Smpk Campus At Nischintapur, Diamond Harbour, Hooghly Point, Falta In The South 24 Parganas District, Swarupganj In The Nadia District And Khejuri In Purba Medinipore Distr
Tender Overview
Project Description
Petty miscellaneous repair works including plumbing & sanitary works at SMPK Campus at Nischintapur, Diamond Harbour, Hooghly Point, Falta in the South 24 Parganas District, Swarupganj in the Nadia District and Khejuri in Purba Medinipore Districtfor the period of one year from the date of placement of work order.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of the foundation tranches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75Mtr as directed. The Item including necessary trimming the sides of tranches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not exceeding 1500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth obtained from excavation of foundation in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. (Payment to be Made on the basis of the Measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 3 | Dismantle all types of Masonry excepting cement concrete plain or reinforced, stacking serviceable Materials at site &removing the rubbish as directed within a lead of 75 Mtr in ground floor including roof. |
| 4 | Dismantle all types of plain cement concrete works up to 150 mm thick stacking serviceable Materials at site andremoving rubbish as directed within a lead of 75 Metre in ground floor including roof upto 150 mm. thick. |
| 5 | Dismantle R.C. floor, roof beams etc. including cutting rods and removingrubbish as directed within a lead of 75 Mtr including stacking of steel bars in ground floor including roof. |
| 6 | Dismantle artificial stone flooring up to 50 mm thick by carefully chiselling without damaging base and removing rubbish as directed within a lead of 75Mtr. In ground floor including roof. |
| 7 | Take out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from the wall / roof after unscrewing bolts, nuts, screws etc. and stacking the Materials at site as directed. (Payment to be Made on measurement of portion of roof wall removed. |
| 8 | Strip off worn out plaster & raking out joints of walls ceilings etc. up to any height and in any floor including,removing rubbish and stacking any where within the compound as directed. |
| 9 | Provide and lay Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 10 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 11 | Provide and lay 25 mm. thick artificial stone in floor dado, staircase etc. with cement concrete (4:2:1) with stone chips with 3 mm. thick topping Made with ordinary/ white cement (as necessary) Marble dust in proportion (2:1) including smooth finishing and rounding of corners and including application of cement slurry before flooring works using cement @ 1.75 kg. / sq. Mtr. all complete including all Materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement in ground floor |
| 12 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 13 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 14 | Hire and labour charges for the shuttering with centering and necessary staging up to 4Mtr using approved stout props and thick hard wood planks with required bracing for concrete slabs, beams and columns, lintels curved or straight including fittings, fixing and striking out after completion of the works (up to roof of ground floor) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer – In – Charge. |
| 15 | 25 mm to 30 mm shuttering without staging in foundation |
| 16 | Hire and Labour Charges for shuttering with hard wood for precast R.C. Slab curved, or stright and striking out the same includingfitting,fixingtheprecastslabin positionwith necessary carriage and haulage, hosting etc, complete in all respect. (only the area in contact with concrete to be measured). |
| 17 | Provide reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary cutting to requisite length, Hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. For works in foundation and upto roof of ground floor/ upto 4Mtr. Tor steel/Mild steel.Other manufacturer not specified. |
| 18 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finishedstructural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, boltsand nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For Structural members of specific section weighing less than 22.5 kg/m. |
| 19 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 20 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 21 | Painting with best quality synthetic enamale paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary.On timber plastered, steel or other metal surface with high gloss of approved quality.One coat with any shade except white in timber or plastered surface Withhi-gloss of approved quality |
| 22 | Two coatsin timber or plastered(with any shade except white) Withhi-gloss of approved quality |
| 23 | Two coats white in shed on timber or plastered surface Withhi-gloss of approved quality |
| 24 | One coat in any shade except white on steel surface.Withhi-gloss of approved quality |
| 25 | Two coats (with any shade except white) on steel surface.Withhi-gloss of approved quality |
| 26 | Removing old scales, blisters, etc. of interior surface of walls, ceiling by scraping, etc. and preparing smooth and even surface with rendering of cement mortar (1:2) (as necessary), to make the surface suitable receiving distemper as per direction of the Engineer at site. |
| 27 | Acrylic Distemperto interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 28 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (Plastered or concrete surface) as per manufacturer’s specification.In ground floor: Two coats. |
| 29 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. In Ground Floor: One Coat |
| 30 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. In Ground Floor: One Coat |
| 31 | Colour washing with any shadewith Strainers, as required including cleaning and smoothening surface thoroughly:Internal surface (All floors) Two coats. Other than yellow, pink. |
| 32 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 33 | Brick work with 1st class bricks in cement morter (1:6). In foundation and plinth |
| 34 | In superstructures, ground floor. |
| 35 | Provide and lay plaster to wall, floor, and ceiling with sand & cement morterincluding rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chipping, etc., including throating, nosing and drip course where necessary in ground floor.20 mm. thick plaster (1:6) |
| 36 | 15 mm. thick plaster (1:6) |
| 37 | 10 mm thick plaster (1:4) |
| 38 | Provide and lay neat cement punning about 1.5 mm. thick in wall, dado, windowsills, floor drain, etc.Note: cement 0.152 Per Cum per 100 sq. Mtr. |
| 39 | Provide and lay flush pointing to brick work in cement morter (1:4) including raking out joints. |
| 40 | Provide and lay rule pointing to brickwork in cement morter (1:4) including raking out joints & top finishing. |
| 41 | Provide 0.80 mm thick galvanised corrugated iron sheet work (excluding the supportingframe work) fitted and fixed with 10 mm dia J or L hook bolts and nuts, limpet and bitumen washers and putty complete with 150 mm end lap and one corrugation Minimum side lap. in roof.(Payment to be made on area of finished work)(GCI sheet tobe supplied by contractor) |
| 42 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof, with 0.5 mm thick sheet. |
| 43 | Providing asbestos corrugated/Trafford or similar approved quality sheet (6 mm. thick) work fitted and fixed with 9.50 mm. dia ‘J’ or ‘L’ hook bolts and nuts, limpet and bitumen washers and putty with 150 mm. end lap and one corrugation minimum side lap complete in roof. (Payment should be made on area of finished work). in roof(Excluding the supporting frame work) |
| 44 | Stop roof leakages in C.I. or G.C.I. or asbestos roofing, closing holes with sheet bolt, limpet and bitumen washer and putty etc. |
| 45 | Galvanised iron sheet ridging fitted with necessary bolts, 300 mm lapping each way screws, washers etc complete.(225mm end lapping) With 0.80 mm sheet |
| 46 | Provide M.S. or W.I. ornamental grill of approved design, joints continuously welded with M.S. W.I. flats and bars for windows railing etc. fitted and fixed with necessary screws and lugs, in ground floor.i) Grill weighing above 10 kg/sq. m. and up to 16 Kg. / Sq. m. The weight of grill per sq. m. will be determined by taking the physical weight of fabricated grill and dividing the same by covered area of the same. No shop priming will be allowed to facilitate inspection of workmanship. Weight of grill is to be taken after final grinding and finishing the weld. |
| 47 | Supplying, fitting, fixing bolts with nuts, washer: 10 to 16 mm dia: Length above 75 mm and upto 150 mm. |
| 48 | Provide iron butt hinges of approved quality fitted and fixed with steel screws, with I.S.I. Mark.75 mm. x 40 mm. x 1.12 mm. |
| 49 | 100 mm. x 58 mm. x 1.90 mm. |
| 50 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:Provide iron socket bolt of approved quality fitted and fixed complete.150 mm. long x 10mm. dia. bolt. |
| 51 | 225 mm. long x 10mm. dia. bolt. |
| 52 | Provide M.S. clamp for fixing door and window frame made of 40 mm. x 6 mm. 125 mm long flat bent bar end bifurcated fixed in cement concrete with stone chips (4:2:1) fitted and fixed as per direction (cost of cement concrete will be paid separately). |
| 53 | Provide 100 mm grip x 10 mm dia anodised aluminium D – Type handle of approved quality manufactured from extruded section conforming to IS specification (IS 230/72) fitted and fixed complete with continuous plate base (hexagonal / round rod). |
| 54 | Provide anodised aluminium door stopper. |
| 55 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. 250mm x 16mm dia bolt. |
| 56 | Iron catch hook of approved quality fitted and fixed to shutter and chowkat6mm dia x 225mm long. |
| 57 | Take out door and window shutters and rehanging the same with old fitting with new iron screws. |
| 58 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of theframe and refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately)a) Upto area 2.5 Per Sqm. |
| 59 | Easing doors and windows. |
| 60 | Take out shutter of door and window dismantling by parts (for repair or replacement of damaged parts) reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 64 will be made once only). |
| 61 | Provide and fix panel shutters of door and window of 35 mm thick shutters with 19 mm. thick panel of size 30 to 45 cm with Sishu, Gamer, Champ, Badam,Bhola, Morga, Hallack as per design (each panels consisting of single plank without joint including the fitting and fixing the same in position but excluding the cost of hinges and other fittings in ground floor. In case of non-supply of single plank panel rate of reduction of 20% well be Made. |
| 62 | Provide woodwork in door and window frame fitted and fixed complete with Malayasian Sal including protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and MS clamp.(The quantum should be corrected upto three decimals)Malayasian Sal. |
| 63 | Supply 35 mm thick solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65 mm wide each and the entire frame fitted with 37.5 mm wide battens placed both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc., complete including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.35 mm thick shutters (single leaf) |
| 64 | Provide and fit 35 mm. thick Glazed shutters with Sishu, Gamer,Champ, Badam,Bhola, Morga, Hallack of doors, window, fan light, clerestory windows, etc. as per design (with ordinary glass of 7.4 kg. / sq. m., 3 mm. thick) fitted with putty bed and teak wood bead and nails including fitting and fixing shutter in position but excluding the cost of hinges and other fittings, cost of glass, putty, wooded beads etc. which will be paid separately in ground floor. |
| 65 | Providing Z-batten shutters of doors and window as per design having tongued and groove half lap joint as per direction of the Engineer-in-Charge including fitting and fixing shutter in position but excluding the cost of hinges and other fittings in ground floor. (Shutter with 25 mm. thick planks 19 mm thick battens withSishu,gamar,champ,badam,Bhola,Morga,Hallak. |
| 66 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. 35 mm thick shutter |
| 67 | Panel (made of single plank) of door and window shutters to design as directed: In Ground Floor (Payment to be made on area of exposed new work). (In case of non-supply of single plank penal rate of reduction to a maximum of 30% will be made). 19mm thick panel of 30cm to 45cm width. Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 68 | Supplying Godrej mortice lock chromium plated with keys 6 levers including fitting & fixing complete. |
| 69 | Godrej Hydraulic door closer fitted and fixed complete. Medium type. |
| 70 | Supply best Indian sheet glass panes 3 mm thick (weighting 7.4 kg. / Sq. Mtr.) Set in putty and fitted and fixed with nails and putty complete in all floors for external wall & upto 6 Metre height for external walls. |
| 71 | Renewing worn out putty of glass panes : Panes not exceeding 0.2 Sq.m. |
| 72 | Renewing PVC rollers for sliding windows as per direction of Engineer in charge. |
| 73 | Renewing maruti lock (100mm) |
| 74 | Taking out rain water down pipe. |
| 75 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamp nails, including Making holes in walls, floor etc. cutting trenches in any soil through Masonry concrete structures etc if necessary and mending good damages including joining with jointing Materials (Spun Yarn, Valamoid/bitumen/M-Seal etc) complete.UPVC Pipes:110 mm. Dia |
| 76 | Bend 87.5 degree 110 mm. Dia. |
| 77 | Fill up the cracks with cement morter (1:3) at the junction of out side wall and drain (cement 11.4 Kg/100 Metre). |
| 78 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 Per Nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.FloorWith Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 79 | Wall With Sand Cement Mortar (1:3)15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 80 | Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineer -in- Charge. (Note: This work should not be xecuted without specific permission ofSuperintending Engineer). ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick). |
| 81 | Renewing X.P.M. including taking out and refixing with old battens but with new screws etc. complete. (20 mm. x 50 mm. strand 2.5 mm. x 1.25 mm). |
| 82 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 83 | Uproot and remove plants from the surface of walls parapet etc. and making good damages. Small plant of girth of exposed stem up to 75 mm. lift up to 6 m. |
| 84 | Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. |
| 85 | Painting block letters or digits in Black Japan or any approved synthetic enamel paint as per direction of Engineer – In – Charge.Size above 2.5 cm and upto 4 cm |
| 86 | Sizeabove 5 cm and upto 7.5 cm |
| 87 | Size above 10 cm and upto 12.5 cm |
| 88 | Size above 12.5 cm and upto 15 cm |
| 89 | Supplying, fitting, Fixing Fly / Mosquito proof nylon net on any type of window, door shutter frame with necessary fixing arrangements complete. |
| 90 | Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical fixture,electrical lines including drilling holes inplaces where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition and furniture). |
| 91 | Welding in M.S. structural work with gas or electric:Tack weld |
| 92 | Continuous weld. |
| 93 | Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. (Payment to be made on the length of individual lines of wire.) |
| 94 | Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T(Reinforced Barbed Tape) Concertina fencing on wall top usingconcertina coils stretched to approx.6 meters length at site clippedwith two nos. of horizontal R.B.T strands which will be tensionedand fixed with the vertical M.S angle iron posts by means ofsecurity fasteners (such as \"C\" clips, R.B.T clips etc.) |
| 95 | Applying two coats of a two component acrylic polymer-modified cementitious high performance coating (SmartCare Damp Block 2K by Asian Paints or similar material ) on wall by brush or roller and necessary tools and tackles over SSD masonry/brick surface.Allow the 1st coat to dry for 4-6 hrs (drying depends on ambient temperature) and then apply 2nd coat.The 1st coat & 2nd coat must be applied in perpendicular direction.Achieve a coverage of 15 sq.ft./kg/coat. all complete as per direction of the Engineer-in-charge. |
| 96 | Supplying and laying 2mm thick Plastic felt sheet (P.B.M Felt 2504 or equivalent brand ) over flat /slope roof for patch repair of leakage area including necessary lapping (75 mm as side lap & 150 mm end lap) whereever necessary after taking out old tarfelt and cleaning the surface thorough. |
| 97 | Finishing with epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specification including appropriate priming coat, preparation of surface etc complete. |
| 98 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceilingwith G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete). In ground floor |
| 99 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer\"s specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 100 | Cutting / cleaning / removing jungles, including uprooting / removing of rank vagetable, cutting grass, bush wood cutting / removing small tree saplings or branches of trees falling under the cutting area at different area of dock and removing spoil up to a distance of 50 m. outside the periphery of the area cleaned as per direction including all lead, lifts, cutting instruments , labours etc. complete in all respect.[Ref: Sanction Special Rate no- 151.C.Cell, dt:08.08.23] |
| 101 | Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914 for Rural Roads of MORD. |
| 102 | Supply of unskilled labour for various non-measurable miscellaneous work. |
| 103 | Earth work in excavation of the foundation tranches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75Mtr as directed. The Item including necessary trimming the sides of tranches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not exceeding 1500 mm. |
| 104 | Earth work in filling in foundation trenches or plinth with good earth obtained from excavation of foundation in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. (Payment to be Made on the basis of the Measurement of finish quality of work). |
| 105 | Dismantle all types of Masonry excepting cement concrete plain or reinforced, stacking serviceable Materials at site &removing the rubbish as directed within a lead of 75 Mtr in ground floor including roof. |
| 106 | Dismantle all types of plain cement concrete works up to 150 mm thick stacking serviceable Materials at site andremoving rubbish as directed within a lead of 75 Metre in ground floor including roof. |
| 107 | Dismantle R.C. floor, roof beams etc. including cutting rods andremoving of rubbish as directed within a lead of 75 Mtr including stacking of steel bars in ground floor including roof. |
| 108 | Dismantle artificial stone flooring up to 50 mm thick by carefully chiselling without damaging base and removing rubbish as directed within a lead of 75Mtr. In ground floor including roof. |
| 109 | Take out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from the wall / roof after unscrewing bolts, nuts, screws etc. and stacking the Materials at site as directed. (Payment to be Made on measurement of portion of roof wall removed. |
| 110 | Strip off worn out plaster & raking out joints of walls ceilings etc. up to any height and in any floor including,removing rubbish and stacking any where within the compound as directed. |
| 111 | Provide and lay Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 112 | Provide and lay 25 mm. thick artificial stone in floor dado, staircase etc. with cement concrete (4:2:1) with stone chips with 3 mm. thick topping Made with ordinary/ white cement (as necessary) Marble dust in proportion (2:1) including smooth finishing and rounding of corners and including application of cement slurry before flooring works using cement @ 1.75 kg. / sq. Mtr. all complete including all Materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement in ground floor |
| 113 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 114 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 115 | Hire and labour charges for the shuttering with centering and necessary staging up to 4Mtr using approved stout props and 25 mm to 30 mm thick hard wood planked with required bracing for concrete slabsbeams, columns, lintels curved or straight including fittings, fixing and striking out after completion of the works (up to roof of ground floor) as per the direction of Engineer – In – Charge. |
| 116 | Hire and Labour Charges for shuttering with hard wood for precast R.C. Slab curved, or stright and striking out the same includingfitting,fixingtheprecastslabin positionwith necessary carriage and haulage, hosting etc, complete in all respect. (only the area in contact with concrete to be measured). |
| 117 | Provide reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary cutting to requisite length, Hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. For works in foundation, basement and up to roof of ground floor/ up to 4Mtr. Tor steel/Mild steel.Other manufacturers not specified. |
| 118 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finishedstructural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, boltsand nuts etc. and no seperate payment being made for theseitems, as per direction of Engineer In Charge. The rates areconsidered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For Structural members of specific section weighing less than 22.5 kg/m. |
| 119 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 120 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 121 | Provide and paint with best quality synthetic enamale paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary. On timber plastered, steel or other metal surface with high gloss of approved quality.One coat with any shade except white in timber or plastered surface Withhi-gloss of approved quality |
| 122 | Two coatsin timber or plastered(with any shade except white) Withhi-gloss of approved quality |
| 123 | Two coats white in shed on timber or plastered surface Withhi-gloss of approved quality |
| 124 | One coat in any shade except white on steel surface.Withhi-gloss of approved quality |
| 125 | Two coats (with any shade except white) on steel surface.Withhi-gloss of approved quality |
| 126 | Remove old scales, blisters, etc., of interior surface of walls, ceiling by scraping, etc., and preparing smooth and even surface with rendering of cement mortar (1:2) as necessary to make the surface suitable receiving distemper as per direction of the Engineer at site. |
| 127 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. In Ground Floor: One Coat |
| 128 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) Normal Acrylic Emulsion. |
| 129 | Acrylic Distemperto interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 130 | Provide and apply two coats decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (Plastered or concrete surface) as per manufacturer’s specification.In ground floor. |
| 131 | Provide and apply two coats white wash including cleaning and smoothening surface thoroughly in all floors. |
| 132 | Provide and apply colour wash with strainer of any shade as required including cleaning and smoothening surface thoroughly.Internal surface (all floors) one coat of colour wash other than yellow and pink. |
| 133 | Providing and lay 125 mm. thick bricks work with 1st class brick in cement morter (4:1).In ground floor |
| 134 | Provide and lay bricks work with 1st class bricks in cement morter (1:6). In foundation and plinth |
| 135 | In superstructures, ground floor. |
| 136 | Provide and lay plaster to wall, floor, and ceiling with sand & cement morterincluding rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chipping, etc., including throating, nosing and drip course where necessary in ground floor.20 mm. thick plaster (1:6) |
| 137 | 15 mm. thick plaster (1:6) |
| 138 | 10 mm thick plaster (1:4) |
| 139 | Provide and lay neat cement punning about 1.5 mm. thick in wall, dado, windowsills, floor drain, etc.Note: cement 0.152 Per Cum per 100 sq. Mtr. |
| 140 | Providing asbestos corrugated/Trafford or similar approved quality sheet (6 mm. thick) work fitted and fixed with 9.50 mm. dia ‘J’ or ‘L’ hook bolts and nuts, limpet and bitumen washers and putty with 150 mm. end lap and one corrugation minimum side lap complete in roof. (Payment should be made on area of finished work). in roof(Excluding the supporting frame work) |
| 141 | Stop roof leakages in C.I. or G.C.I. or asbestos roofing, closing holes with sheet bolt, limpet and bitumen washer and putty etc. |
| 142 | Provide iron butt hinges of approved quality fitted and fixed with steel screws, with I.S.I. Mark.75 mm. x 40 mm. x 1.12 mm. |
| 143 | 100 mm. x 58 mm. x 1.90 mm. |
| 144 | Provide iron socket bolt of approved quality fitted and fixed complete.150 mm. long x 10mm. dia. bolt. |
| 145 | 225 mm. long x 10mm. dia. bolt. |
| 146 | Provide M.S. clamp for fixing door and window frame made of 40 mm. x 6 mm. 125 mm long flat bent bar end bifurcated fixed in cement concrete with stone chips (4:2:1) fitted and fixed as per direction (cost of cement concrete will be paid separately). |
| 147 | Provide and fix 250 mm long Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm dia rod with centre bolt and round fittings. |
| 148 | Iron catch hook of approved quality fitted and fixed to shutter and chowkat6mm dia x 225mm long. |
| 149 | Take out door and window shutters and rehanging the same with old fitting with new iron screws. |
| 150 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of theframe and refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately)a) Upto area 2.5 Per Sqm. |
| 151 | Easing doors and windows. |
| 152 | Take out shutter of door and window dismantling by parts (for repair or replacement of damaged parts) reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 64 will be made once only). |
| 153 | Provide and fix panel shutters of door and window of 35 mm thick shutters with 19 mm. thick panel of size 30 to 45 cm with Sishu, Gamer,Champ, Badam, Bhola, Morga, HallackWood as per design (each panels consisting of single plank without joint including the fitting and fixing the same in position but excluding the cost of hinges and other fittings in ground floor. In case of non-supply of single plank panel rate of reduction of 20% well be Made. |
| 154 | Provide woodwork in door and window frame fitted and fixed complete with Malayasian Sal including protective coat of painting at the contact surface of theframe excluding cost of concrete, Iron Butt Hinges and MS clamp.(The quantum should be corrected upto three decimals)Malayasian Sal. |
| 155 | Providing Z-batten shutters of doors and window as per design having tongued and groove half lap joint as per direction of the Engineer-in-Charge including fitting and fixing shutter in position but excluding the cost of hinges and other fittings in ground floor. (Shutter with 25 mm. thick planks 19 mm thick battens withSishu,gamar,champ,badam,Bhola,Morga,Hallak. |
| 156 | Supply best Indian sheet glass panes 3 mm thick (weighting 7.4 kg. / Sq. Mtr.) Set in putty and fitted and fixed with nails and putty complete in all floors for external wall & upto 6 Metre height for external walls. |
| 157 | Fill up the cracks with cement morter (1:3) at the junction of out side wall and drain (cement 11.4 Kg/100 Metre). |
| 158 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 Per Nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.FloorWith Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile upto 0.09 Sq.m(i) Coloured decorative |
| 159 | Wall With Sand Cement Mortar (1:3)15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative |
| 160 | Renew XPM including taking out and refixing with old battens but with new screws, etc., complete (20 mm. x 50 mm. strand 2.5 mm. x 1.25 mm). |
| 161 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) |
| 162 | Uproot and remove plants from the surface of walls parapet etc. and making good damages.Small plant of girth of exposed stem up to 75 mm. lift up to 6 m. |
| 163 | Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. |
| 164 | Painting block letters or digits in Black Japan or any approved synthetic enamel paint as per direction of Engineer – In – Charge.Size above 2.5 cm and upto 4 cm |
| 165 | Sizeabove 5 cm and upto 7.5 cm |
| 166 | Size above 10 cm and upto 12.5 cm |
| 167 | Size above 12.5 cm and upto 15 cm |
| 168 | Supplying, fitting, Fixing Fly / Mosquito proof nylon net on any type of window, door shutter frame with necessary fixing arrangements complete. |
| 169 | Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical Sq.M. fixture,electrical lines including drilling holes in- places where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition andfurniture) |
| 170 | Cutting / cleaning / removing jungles, including uprooting / removing of rank vagetable, cutting grass, bush wood cutting / removing small tree saplings or branches of trees falling under the cutting area at different area of dock and removing spoil up to a distance of 50 m. outside the periphery of the area cleaned as per direction including all lead, lifts, cutting instruments , labours etc. complete in all respect. |
| 171 | Cutting of branches of trees and shrubs from the road way or with in R.O.W including disposal of wood and leaves to suitable location as per technical specification Clause 1914 for Rural Roads of MORD. |
| 172 | Earth work in excavation of the foundation tranches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75Mtr as directed. The Item including necessary trimming the sides of tranches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not exceeding 1500 mm. |
| 173 | Earth work in filling in foundation trenches or plinth with good earth obtained from excavation of foundation in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. (Payment to be Made on the basis of the Measurement of finish quality of work). |
| 174 | Dismantle all types of Masonry excepting cement concrete plain or reinforced, stacking serviceable Materials at site &removing the rubbish as directed within a lead of 75 Mtr in ground floor including roof. |
| 175 | Dismantle all types of plain cement concrete works up to 150 mm thick stacking serviceable Materials at site andremoving rubbish as directed within a lead of 75 Metre in ground floor including roof. |
| 176 | Dismantle artificial stone flooring up to 50 mm thick by carefully chiselling without damaging base and removing rubbish as directed within a lead of 75Mtr. In ground floor including roof. |
| 177 | Take out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from the wall / roof after unscrewing bolts, nuts, screws etc. and stacking the Materials at site as directed. (Payment to be Made on measurement of portion of roof wall removed. |
| 178 | Strip off worn out plaster & raking out joints of walls ceilings etc. up to any height and in any floor including,removing rubbish and stacking any where within the compound as directed. |
| 179 | Provide and lay Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 180 | Provide and lay 25 mm. thick artificial stone in floor dado, staircase etc. with cement concrete (4:2:1) with stone chips with 3 mm. thick topping Made with ordinary/ white cement (as necessary) Marble dust in proportion (2:1) including smooth finishing and rounding of corners and including application of cement slurry before flooring works using cement @ 1.75 kg. / sq. Mtr. all complete including all Materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement in ground floor |
| 181 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 182 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 183 | Hire and labour charges for the shuttering with centering and necessary staging up to 4Mtr using approved stout props and 25 mm to 30 mm thick hard wood planked with required bracing for concrete slabs,beams, columns, lintels curved or straight including fittings, fixing and striking out after completion of the works (up to roof of ground floor) as per the direction of Engineer – In – Charge. |
| 184 | Hire and Labour Charges for shuttering with hard wood for precast R.C. Slab curved, or stright and striking out the same includingfitting,fixingtheprecastslabin positionwith necessary carriage and haulage, hosting etc, complete in all respect. (only the area in contact with concrete to be measured). |
| 185 | Provide reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary cutting to requisite length, Hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. For works in foundation, basement and up to roof of ground floor/ up to 4Mtr. Tor steel/Mild steel.Other manufacturers not specified. |
| 186 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finishedstructural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for theseitems, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For Structural members of specific section weighing less than 22.5 kg/m. |
| 187 | Provide and paint with best quality synthetic enamale paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary. On timber plastered, steel or other metal surface with high gloss of approved quality.Two coatsin timber or plastered(with any shade except white) Withhi-gloss of approved quality |
| 188 | Two coats (with any shade except white) on steel surface.Withhi-gloss of approved quality |
| 189 | Remove old scales, blisters, etc., of interior surface of walls, ceiling by scraping, etc., and preparing smooth and even surface with rendering of cement mortar (1:2) as necessary to make the surface suitable receiving distemper as per direction of the Engineer at site. |
| 190 | Provide and apply two coats decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (Plastered or concrete surface) as per manufacturer’s specification.In ground floor. |
| 191 | Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats):External surface (Ground floor)One coat |
| 192 | Provide and apply two coats white wash including cleaning and smoothening surface thoroughly in all floors. |
| 193 | Provide and apply colour wash with strainer of any shade as required including cleaning and smoothening surface thoroughly.Internal surface (all floors) one coat of colour wash other than yellow and pink. |
| 194 | Providing and lay 125 mm. thick bricks work with 1st class brick in cement morter (4:1).In ground floor |
| 195 | Provide and lay bricks work with 1st class bricks in cement morter (1:6). In foundation and plinth |
| 196 | In superstructures, ground floor. |
| 197 | Provide and lay plaster to wall, floor, and ceiling with sand & cement morterincluding rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chipping, etc., including throating, nosing and drip course where necessary in ground floor.20 mm. thick plaster (1:6) |
| 198 | 15 mm. thick plaster (1:6) |
| 199 | Provide and lay neat cement punning about 1.5 mm. thick in wall, dado, windowsills, floor drain, etc.Note: cement 0.152 Per Cum per 100 sq. Mtr. |
| 200 | Providing asbestos corrugated/Trafford or similar approved quality sheet (6 mm. thick) work fitted and fixed with 9.50 mm. dia ‘J’ or ‘L’ hook bolts and nuts, limpet and bitumen washers and putty with 150 mm. end lap and one corrugation minimum side lap complete in roof. (Payment should be made on area of finished work). in roof(Excluding the supporting frame work) |
| 201 | Stop roof leakages in C.I. or G.C.I. or asbestos roofing, closing holes with sheet bolt, limpet and bitumen washer and putty etc. |
| 202 | Provide iron butt hinges of approved quality fitted and fixed with steel screws, with I.S.I. Mark.100 mm. x 58 mm. x 1.90 mm. |
| 203 | Provide iron socket bolt of approved quality fitted and fixed complete.150 mm. long x 10mm. dia. bolt. |
| 204 | 225 mm. long x 10mm. dia. bolt. |
| 205 | Provide M.S. clamp for fixing door and window frame made of 40 mm. x 6 mm. 125 mm long flat bent bar end bifurcated fixed in cement concrete with stone chips (4:2:1) fitted and fixed as per direction (cost of cement concrete will be paid separately). |
| 206 | Provide and fix 250 mm long Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm dia rod with centre bolt and round fittings. |
| 207 | Take out door and window shutters and rehanging the same with old fitting with new iron screws. |
| 208 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of theframe and refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately)a) Upto area 2.5 Per Sqm. |
| 209 | Easing doors and windows. |
| 210 | Take out shutter of door and window dismantling by parts (for repair or replacement of damaged parts) reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 64 will be made once only). |
| 211 | Provide and fix panel shutters of door and window of 25 mm thick shutters with 12 mm. thick panel of size 30 to 45 cm with sishu,gamer,Champ,Badam,Bhola,Morga,Hallock Wood as per design (each panels consisting of single plank without joint including the fitting and fixing the same in position but excluding the cost of hinges and other fittings in ground floor. In case of non-supply of single plank panel rate of reduction of 20% well be Made. |
| 212 | Provide woodwork in door and window frame fitted and fixed complete with Malayasian Sal including protective coat of painting at the contact surface of theframe excluding cost of concrete, Iron Butt Hinges and MS clamp.(The quantum should be corrected upto three decimals)Malayasian Sal. |
| 213 | Providing Z-batten shutters of doors and window as per design having tongued and groove half lap joint as per direction of the Engineer-in-Charge including fitting and fixing shutter in position but excluding the cost of hinges and other fittings in ground floor. (Shutter with 25 mm. thick planks 19 mm thick battens withSishu,gamar,champ,badam,Bhola,Morga,Hallak. |
| 214 | Fill up the cracks with cement morter (1:3) at the junction of out side wall and drain (cement 11.4 Kg/100 Metre). |
| 215 | Uproot and remove plants from the surface of walls parapet etc. and making good damages.Small plant of girth of exposed stem up to 75 mm. lift up to 6 m. |
| 216 | Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. |
| 217 | Painting block letters or digits in Black Japan or any approved synthetic enamel paint as per direction of Engineer – In – Charge.Size above 2.5 cm and upto 4 cm |
| 218 | Sizeabove 5 cm and upto 7.5 cm |
| 219 | Size above 10 cm and upto 12.5 cm |
| 220 | Size above 12.5 cm and upto 15 cm |
| 221 | Spot application for insecticides using Aqua base spray for pest (for bugs, cockroaches, silverfish, spider, termites, mosquitoes) to walls and ceiling etc. with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying the emulsified chemical @ 0.5 litres per sq.m. by a hand operated pressure pump on wall surfaces, ceiling, electrical Sq.M. fixture,electrical lines including drilling holes in- places where source of termite is detected squirting chemical solution into the holes and sealing the holes with cement grout. (Rate is per sq.m. of the floor area while actual work will be all walls ceiling, rack, partition andfurniture). |
| 222 | Labour for dismantling G.I. pipe with fittings.15 mm |
| 223 | 20 mm |
| 224 | 25 mm |
| 225 | 32 mm |
| 226 | 40 mm |
| 227 | Refixing G.I. pipe with fittings after cleaning where necessary.15 mm |
| 228 | 20 mm |
| 229 | 25 mm |
| 230 | 32 mm |
| 231 | 40 mm |
| 232 | Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in allrespect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground.(Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes(Dia)15 mm |
| 233 | 20 mm |
| 234 | 25 mm |
| 235 | 32 mm |
| 236 | 40 mm |
| 237 | (a)RenewingChromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 238 | (b) Renewing Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 239 | ( c ) Renewing Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 240 | Supplying, fitting and fixing Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO /ATLAS or equivalent)15 mm |
| 241 | Chromium plated Bib Cock short body (Equivalent to Code No.511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 242 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes and fittings conforming to IS: 15778 - 2007.Male threaded adopter (brass threaded) (Dia) (i) 20 mm |
| 243 | (ii) 25 mm |
| 244 | (iii) 32 mm |
| 245 | (iv) 40 mm |
| 246 | Female threaded adopter (brass threaded) (Dia) (i) 20 mm |
| 247 | (ii) 25 mm |
| 248 | (iii) 32 mm |
| 249 | (iv) 40 mm |
| 250 | Compact Ball Valve with SS Handle for CPVC/UPVC Fittings. (As per ASTM D 2467, Schedule 80) (Dia) (i) 25 mm |
| 251 | (ii) 32 mm |
| 252 | (iii) 40 mm |
| 253 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 254 | Cleaning and disinfecting upto 2000 litre Water Tank including masonry reservoir. |
| 255 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size |
| 256 | Dismantling wash basin with brackets with or without waste fittings. |
| 257 | Renewing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia, 600 mm long. |
| 258 | Renewing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 750 mm long. |
| 259 | Renewing CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 260 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. 600 mm X 450 mm |
| 261 | Supplying, fitting and fixing glass shelf with aluminium guard rails. Ordinary type with 5.5 mm sheet glass 600 mm X 125 mm. |
| 262 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. Upto 30 users:-Within a lead of 150 metre |
| 263 | Dismantling and refixing pit cover. |
| 264 | Cleaning silt from inspection pit. |
| 265 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C. Plastic (hallow type) white |
| 266 | Removing chokage of H.C.I. or S.W. pipe with split bambooUnderground. |
| 267 | Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). 150 mm |
| 268 | Supply of UPVC pipes (B Type)conforming to IS-13592-1992 Single Socketed 3 Meter Length(a)110 mm |
| 269 | (b) 160 mm |
| 270 | ( c ) 75 mm |
| 271 | Double Socketed 3 Meter Length(a) 110 mm |
| 272 | (b) 160 mm |
| 273 | Single Socketed 1.8 Meter Length(a)100 mm |
| 274 | Double Socketed 1.8 Meter Length(a)110 mm |
| 275 | Double Socketed 1.2 Meter Length(a)110 mm |
| 276 | Double Socketed 0.9 Meter Length(a)110 mm |
| 277 | Double Socketed 0.60 Meter Length(a)110 mm |
| 278 | Supply of UPVC fittingsconforming to IS-13592-1992Coupler (a) 110 mm |
| 279 | (b) 160 mm |
| 280 | Plain Tee (a) 110 mm |
| 281 | (b) 160 mm |
| 282 | Door Tee (a)100 mm |
| 283 | (b) 160 mm |
| 284 | Bend 45 degree (a)110mm |
| 285 | (b) 160 mm |
| 286 | Bend 87.5 degree(a)110 mm |
| 287 | (b) 160 mm |
| 288 | Door bend (T.S.) (a)110mm |
| 289 | (b) 160 mm |
| 290 | Vent Cowl 110 mm |
| 291 | Pipe Clip(a)110 mm |
| 292 | (b) 160 mm |
| 293 | Reducing Tee (160 x 110 mm) 75 mm |
| 294 | Reducing Tee (160 x 75 mm) 75 mm |
| 295 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.)Above ground.(a) 75 mm dia. |
| 296 | (b) 110 mm dia. |
| 297 | (c) 160 mm dia. |
| 298 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.With \"P\" trap |
| 299 | Making connection with the existing pit. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender