| 1 | Laying and fixing of one no PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of Upto 35 sq.mm (clamped with 1mm thick saddle) size on wall surface/metal truss as required. |
| 2 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm size in the existing masonry open duct as required. |
| 3 | Supplying and making end termination with brass ompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 4 | 4 X 10 sq. mm (25mm) |
| 5 | 4 X 16 sq. mm (28mm) |
| 6 | Providing and fixing 25 mm X 5 mm copper strip with insulation sleeve on surface or in recess for connections etc. as required |
| 7 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 8 | Providing and fixing 6 SWG dia G.I. wire with insulation sleeve on surface or in recess for loop earthing as required. |
| 9 | Providing and fixing 4.00 mm dia copper wire with insulation sleeve on surface or in recess for loop earthing as required |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 11 | 8 way , Double door |
| 12 | 12 way , Double door |
| 13 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 14 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Single pole |
| 17 | Triple pole |
| 18 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 19 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same as required. |
| 20 | 20 mm |
| 21 | 25 mm |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated Copper conductor, single core cable in the existing surface/ recessed PVC conduit as required. |
| 23 | 1 x 1.5 sq. mm |
| 24 | 2 x 1.5 sq. mm |
| 25 | 2 x 2.5 sq. mm |
| 26 | 2 x 4.0 sq. mm |
| 27 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate as required. |
| 28 | 5/6 A switch |
| 29 | 15/16 A SP switch |
| 30 | 3 pin 5/6 A socket outlet |
| 31 | 6 pin 15/16A socket outlet |
| 32 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, ceiling rose, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(group c) |
| 34 | Wiring for group controlled (looped) light point/ fanpoint/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVCconduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-C) |
| 35 | Installation, Testing, Commissioning of wall bracket /ceiling/surface fittings(LED) of all sizes and shapes containing upto two LED lamps per fitting, complete with all accessories including connections with 3C*1.5 sq.mm copper Flexible cable as etc. as required. |
| 36 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. including fixing fan hook in ceiling Complete as required. |
| 37 | Supply of following size and Core Aluminium/ Copper conductor 1.1kV gradeXLPE insulated,PVC sheathed, armoured/ unarmoured UG cable in one length as per IS : 7098 (Pt-1) 1988 |
| 38 | 4 Core 25 sqmm Aluminium Armoured Cable |
| 39 | 4 Core 10 sqmm Aluminium Armoured Cable |
| 40 | 3 Core 10 sqmm Copper Armoured Cable |
| 41 | 3 Core 6 sqmm Copper Armoured Cable |
| 42 | 3 Core 10 sqmm Copper Unarmoured Cable |
| 43 | 4 core 6 sqmm Copper Unarmoured Cable |
| 44 | Supplying and making end termination with nylon PG nylon gland/ brass compression gland for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade including necessary metal cable tag as required. |
| 45 | 4 Core 6 sqmm Copper Unarmoured Nylon PG Gland (19mm) |
| 46 | 3 Core 6 sqmm Copper armoured Brass compression gland (19mm) |
| 47 | 3 Core 10 sqmm Copper armoured Brass compression gland (22mm) |
| 48 | 3 Core 10 sqmm Copper Unarmoured Nylon PG Gland (22mm) |
| 49 | Supplying and fixing 4 way sheet steel MCB enclosure on surface with necessary accessories. |
| 50 | Supplying and fixing of following rating, 240/415 V, 10 kA, following curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 51 | TPN 63A rating, \"C\" Curve |
| 52 | TPN 5-32A rating, \"C\" Curve |
| 53 | SPN 5-32A rating, \"D\" Curve |
| 54 | SP 5-32A rating, \"D\" Curve |
| 55 | Supplying and fixing of following sizes of DLP PVC snap on trunking with divider including cover along with accessories on surfaceincluding cutting the wall and making good the same as required. |
| 56 | 100 X 50 mm |
| 57 | 80 X 50 mm |
| 58 | Supplying and fixing of 32 X 16 mm sizes of DLP PVC mini trunking including cover along with accessories on surfaceincluding cutting the wall and making good the same as required. |
| 59 | Removing of existing circuits (3x2.5sqmm) and rerouting the same circuits in the existing trunking including disconnection and connections as required. (Note: Above circuits are already layed in the trunking) |
| 60 | Supply,installation,testing and commissioning of maintenance free earthing withGI dual pipe of 2000mm long (min)75mm dia as outer pipe with (min) 45mm dia of inner pipe of 80-100 microns galvanized, filled with highly conducting metallic compounds with the permanent sealing at both the ends and lead terminal of 50 X 8 mm size at the top the length of the electrode shall be 2000 mm excluding the lead terminal and the length of the lead terminal at the top shall be 100 mm. To ensure the moisture content and electrical conductivity, resistance lowering grounding minerals shall be filled around the electrode (min 25kgs). Heavy duty weather proof plastic earth pit chamber with cover of dimension 250mm dia (top), 330mm dia(bottom) and 260mm (height) shall be used, Numbering of pit and measured value shall bewritten with weather proof paintingor stickering. |
| 61 | Supply,installation,testing and commissioning of maintenance free earthing with copper single pipe of2000mm long (min)45mm dia pipe with thickness of 1.6 to 1.8mm, filled with highly conducting metallic compounds with the permanent sealing at both the ends and lead terminal of 50 X 8 mm size at the top, the length of the electrode shall be 2000 mm excluding the lead terminal and the length of the lead terminal at the top shall be 100 mm. To ensure the moisture content and electrical conductivity, resistance lowering grounding minerals shall be filled around the electrode (min 25kgs). Heavy duty weather proof plastic earth pit chamber with cover and locking facility of dimension 254mm dia (top), 330mm dia(bottom) and 260mm (height) shall be used, Numbering of pit and measured value shall be written with weather proof paintingor stickering. |
| 62 | Supplying and fixing of following size PVC modular box along with modular base & cover plate for modular switches on surface etc. as required. |
| 63 | 8 way modular box |
| 64 | 3 way modular box |
| 65 | Supply of 10W to 12W,240 V, Square type, colour temperature of min. 5700 deg kelvin, surface mounted LED fitting complete set with suitable driver with inbuilt protection in powder coated CRCA housing, ,protected from dust and insects as required. |
| 66 | Supply of 36W to 40W, 240 V, minimum colour temperature min. 5700 deg kelvinwith luminous efficiency of 100 lumen/watt, surface type 4 ft. x 1 ft. length LED luminaire complete set with suitable driver with inbuilt protection in powder coated CRCA housing, protected from dust and insects as required. |
| 67 | Supply of 200 mm sweep, heavy duty, metal body, exhaust fan to operate on single phase 230 V,50 Hz supply including suitable louvers with frame complete set as required. Making of necessary size hole for the exhaust fan by core cutting methodon the wall and installtion of Exhaust fan with necessary accesories including fixing a mesh trap on the other side of wall to prevent rodent and insect entry |
| 68 | Supplying & fixing of powder coated extruded aluminium Air Grills with necessary accesories of 01 sqft including making necessary cut out in existing brick masonary wall and making good the same. |
| 69 | Supply and installation of Timer for fan control Manual Switching ON / Automatic / OFFDaily Switching dial with capitive segments, Clock Precision +/- 5 Min for the daily time switch -10deg to +55degC Operating temparature and with 8 Way Bakelite connector and all required accessories and wiring complete, fixed in the FRP box of dimension (145x145x90 mm) as required. |
| 70 | SITC of UPS Distribution Power Board for 230V, single phase, 3 wire AC supply (UPS power) made of 2mm thick CRCA sheet steel, dust, vermin proof, welded construction, wall mounting, double door type having transparent cover with acrylic or similar for visibility of MCB, indications and metering, with following components interconnected:INCOMER63A, 2Pole, \"D\" Curve, 10 kA MCB.....1 Noa) Indication Lamps with control MCB ….. 1 set b) Suitable rated Multi-function meter along with necessary moulded CT\"s class-1 with short link connected TB,s and RS 485 feature and wired terminals.….. 1 setc) Earth Bus & Terminalsd) Outgoing : 1. 25ADP “D” curve 10KA MCB- 6 Nos |
| 71 | Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |