| 1 | M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 2 | M&L for Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed by Engineer-in-charge. |
| 3 | M&L for laying 25mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid intrenches/ fixed to wall including taking down the existing old unserviceable CI/GI/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge. |
| 4 | All as per Item No. 03 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 5 | All as per Item No. 03 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 6 | All as per Item No. 03 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 7 | All as per Item No. 03 here-in-above, but for 63mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 8 | All as per Item No. 03 here-in-above, but for 90mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 9 | All as per Item No. 03 here-in-above, but for 110mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 10 | Labour only for laying/fixing of serviceable GI/PP-R pipe of any type of 50/63mm dia for hot & cold water supply with allfittings laid intrenches/ fixed to wall including taking down the existing CI/GI/PP-R pipe, cleaning the same for re-use and testing, complete all as specified and as directed by Engineer-in-charge. |
| 11 | All as per Item No. 10 here-in-above, but for 80/90mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 12 | All as per Item No. 10 here-in-above, but for 100/110mm dia pipe, complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F in-repair of 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge. |
| 14 | S&F in-repair of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge. |
| 15 | S&F in-repair of 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F in-repair of 63mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for repairing of sluice valve of 100mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge. |
| 18 | M&L for repairing of sluice valve of 150mm dia by replaceng GI Spindle, CI gate mechanical sealing, complete all as specified and as directed by Engineer-in-charge. |
| 19 | Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gasketsincluding taking out old unserviceable sluice valves, complete all as specified and as directed by Engineer-in-charge. |
| 20 | All as per Item No. 19 here-in-above, but for 100mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge. |
| 21 | All as per Item No. 19 here-in-above, but for 150mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge. |
| 22 | Supply & Fixing, jointing and testing of cast iron Non Return Valve (NRV) ISI mark (PN-1.6) of size 80 mm bore, without bypass arrangement, swing type, conforming to IS-5312, complete with nuts, bolts, washers and gasketsincluding taking out old unserviceable NRV, complete all as directed by Engineer-in-charge. |
| 23 | All as per Item No. 22 here-in-above, but for 100mm dia cast iron Non Return Valve (NRV) ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge. |
| 24 | M&L for Making connection of PP-R distribution branch with PP-R main of 16-40mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge. |
| 25 | M&L for Making connection of PP-R distribution branch with PP-R main of 50-75mm dia by providing and fixing tee including cutting and making fusion joint etc., complete all as specified and as directed by Engineer-in-charge. |
| 26 | M&L for Cutting and Screwing existing 80-100mm dia steel tubing for alterations or additions (or lengthening screw on pipe to form connector), complete all as specified and as directed by Engineer-in-charge. |
| 27 | M&L for construction of Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 3mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as directed by Engineer-in-charge. |
| 28 | All as per Item No. 27 here-in-above, but for 600mm X 600mm X 600mm (Internal dimension) valve pit, complete all as specified and as directed by Engineer-in-charge. |
| 29 | S&F in-repair of rubber packing sheet of 6mm thick, complete all as specified and as directed by Engineer-in-charge. |
| 30 | M&L for Overhauling of centrifugal/monoblock pump set of capacity15HP to 30 HPafter removing from base plate disconnecting from pipe line and dismantling pump set, replacing US gland packing, gun metal bush, bearing and water seal and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts andnew gasket including dismantling the motor, cleaning the rotor, starter, varnishing, backing etc and reassembling the motor and painting motor and pump sets including suction and discharge pipe line with one coat of paint with spray painting also connecting the existing cable etc.including testing the pump set for full satisfaction of in-charge complete all as specified and directed.Note: 1. Defective major components/spares if required to be replaced shall be measured as supply only under respective item here-in-after and labour element included in item No 30 for replacement of major spares/components. |
| 31 | Supply only Ball bearings any type suitable for pump set of capacity15HP to 30 HP |
| 32 | Supply only CI Impellerany type suitable for pump set of capacity15HP to 30 HP |
| 33 | Supply onlyShaft stainless steel along with key and check nut of any type suitable for pump set of capacity15HP to 30 HP |
| 34 | Supply only Oval flange bearing unit of any type suitable for pump set of capacity15HP to 30 HP |
| 35 | Supply only Rubber coupling of any type suitable for pump set of capacity15HP to 30 HP |
| 36 | S&F in-repair of motor ball bearing as per existing suitable for motor upto 50 HP, complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F in-repair of pump ball bearing as per existing suitable for motor upto 50 HP, complete all as specified and as directed by Engineer-in-charge. |
| 38 | M & L for cleaning of PS/RCC OHT of any capacity through 6 stage (Mechanized Dewatering, Sludge Removal, High Pressure Cleaning, Vaccum cleaning, Antibacterial spray, UV radiation through govt authroized farm for cleaning overhead tank and sumps) cleaning process by involving the following six stages of cleaning processes and all as directed by the Engineer-in-Charge.(i) Suitably blocking the incoming and outgoing and wash out pipes for avoiding mud and foreign materials deposited in the reservoir getting in to pipes and chocking it prior to starting the cleaning.(ii) De-watering by high pressure German submersible pump all as complete(iii) Total removal of sludges by German suction pumps all as complete(iv) Cleaning of walls, ceiling & floor by high pressure German jet of 80 - 180 bar pressure all as complete(v) Removal of all dirt particals and sludge by vacuum pump specially designed all as complete(vi)Disinfect the tank with FOA/WHO specified chemical and make the tank totally bacteria free.(vii) Sterilization of tank completely atmosphere by industrial ultra-violet radiation leaving the tank completely sterilized all as complete(viii) Remove the blockage from inlet/outlet/over flow pipes, refill the tank with water and supply water at supply timings ensure satisfactory distribution |
| 39 | All as per serial item No 38 here-in-above but for Semi-underground sump of any capacity, complete all as specified and as directed by Engineer-in-charge. |
| 40 | M&L for preparation of external surfaces of pressure type iron removal filtration plant, dual media pressure sand filter & activated carbon filter of 8000 to 10000 GPH capacity including connected external steel components and applying one coat of synthetic enamel paint same as existing colour, complete all as specified and as directed by Engineer-in-Charge. Note- Cost of scaffolding, T&P and any material required to complete the job as per the direction of Engineer -in-Charge shall be deemed to the quoted rate. |
| 41 | M&L for surface preparation for painting of inner surface of water tank sheet after removing all foreign particals from steel surfaces by srubbing the wall with iron scrubber and apply one coat of black bituminous paint suitable for drinking purpose in pressed steel water tank of 45000 Ltr capacity on 40 feet stagingon inner wall of tank, roof sheet, manhole cover, channels, tie rod etccomplete all as specified and as directed by Engineer-in-charge.Note- Cost of scaffolding, T&P and any material required to complete the job as per the direction of Engineer -in-Charge shall be deemed to the quoted rate. |
| 42 | All as per serial item No 41 here-in-above but for RCC OHT of upto 100000 Ltr capacity, complete all as specified and as directed by Engineer-in-charge. |
| 43 | All as per serial item No 41 here-in-above but for RCC OHT of 100001 to 230000 Ltr capacity, complete all as specified and as directed by Engineer-in-charge. |
| 44 | All as per serial item No 41 here-in-above but for RCC semi-underground sump of upto 100000 Ltr capacity, complete all as specified and as directed by Engineer-in-charge. |
| 45 | All as per serial item No 41 here-in-above but for RCC semi-underground sump of 100001 to 230000 Ltr capacity, complete all as specified and as directed by Engineer-in-charge. |
| 46 | M&L for opening of pressure type iron removal plant of8000 to 10000 GPH capacity, taking out and removing old filter media such as ferro, minex, PVC type strainer nozzles, carbo-felt, filter sand, gravel, grits, etc. from filtration plant and depositing to a distance exceeding 25m but not exceeding 50m complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for opening of dual media pressure sand filter of8000 to 10000 GPH capacity, taking out and removing old filter media such as ferro, minex, PVC type strainer nozzles, carbo-felt, filter sand, gravel, grits, etc. from filtration plant and depositing to a distance exceeding 25m but not exceeding 50m complete all as specified and as directed by Engineer-in-charge. |
| 48 | M&L for opening of Activated carbon filter of8000 to 10000 GPH capacity, taking out and removing old filter media such as ferro, minex, PVC type strainer nozzles, carbo-felt, filter sand, gravel, grits, etc. from filtration plant and depositing to a distance exceeding 25m but not exceeding 50m complete all as specified and as directed by Engineer-in-charge. |
| 49 | M&L for preparation of internal steel surfaces of pressure type iron removal filtration plant, dual media pressure sand filter & Activated carbon filter of 8000 to 10000 GPH capacity by scraping with wire brush and removing all dust, scales and other foreign particles and thoroughly washing with clean water and after drying apply two coats of anti-corrosive black bituminous paint suitable for drinking purpose on entire internal surfaces (except glavanised surfaces) of filtration plants complete all as specified and as directed by Engineer-in-charge. |
| 50 | S&F push fit PVC strainer nozzles 12 mm dia complete all as specified and as directed by Engineer-in-charge. |
| 51 | Supplying and charging in layers special fine sand suitable for use in filtration plant of size 2 x 6 mm mesh complete all as specified and as directed by Engineer-in-charge. |
| 52 | Supplying and charging in layers special coarse sand suitable for use in filtration plant of size 16 x 32 mm mesh complete all as specified and as directed by Engineer-in-charge. |
| 53 | Supplying and charging in layers new washed, cleaned, dust free, well graded gravels filter media suitable for use in filtration plant of the size 10mm complete all as specified and as directed by Engineer-in-charge. |
| 54 | Supplying and charging in layers new washed, cleaned, dust free, well graded gravels filter media suitable for use in filtration plant of the size 15mm complete all as specified and as directed by Engineer-in-charge. |
| 55 | Supplying and charging in layers new washed, cleaned, dust free, well graded gravels filter media suitable for use in filtration plant of the size 20mm complete all as specified and as directed by Engineer-in-charge. |
| 56 | Supplying and charging in layers new washed, cleaned, dust free, well graded gravels filter media suitable for use in filtration plant of the size 25mm complete all as specified and as directed by Engineer-in-charge. |
| 57 | Supplying and charging in layers new washed, cleaned, dust free, well graded gravels filter media suitable for use in filtration plant of the size 40mm complete all as specified and as directed by Engineer-in-charge. |
| 58 | Supply and charging in layers manganese dioxide (MnO2) treated charcoal in lumps of sizes 20 mm to 15 mm containing at least 65% of manganese, suitable for use in filtration plant complete all as specified and as directed by Engineer-in-charge. |
| 59 | Supply and charging in layers Granule Anthracitein lumps suitable for use in filtration plant complete all as specified and as directed by Engineer-in-charge. |
| 60 | Supply and charging in layers Activated carbon suitable for use in filtration plant complete all as specified and as directed by Engineer-in-charge. |
| 61 | Supply and lowering of MS column pipe of 10 feet long both side flange, duly welded flange heavy duty \"C\" grade of size 80 mm dia including nuts, bolts, washer and gasket etc complete all as specified and diredted. Make: TATA/Bansal/Jindal |
| 62 | M&L for mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge. |
| 63 | M&L for overhauling and repair of 3 Phase, submersible pump set of any make and of capacity 10 HP to 20 HP by disconnecting electrical/ mechanical connections and taking out pump from existing bore well with all accessories such as column pipe etc and transporting to authorized workshop to carry out repair work including replacement of minor unserviceable components/spares like nuts, bolts, washer & the like and reassemble all the parts/portions and refix at same position, including re-lowering in same bore well with all accessories,reconnecting and making connection with starterincluding re-commissioning and testing to ensure efficient and smooth functioning to obtain required discharge, etc complete all as specified and directed.Note: 1. Defective major components/spares if required to be replaced shall be measured as supply only under respective item here-in-after and labour element included in item No 63 for replacement of major spares/components. |
| 64 | Supply only stainless steel shaft for submersible pumpof capacity10to 20 HP as per sample. |
| 65 | Supply only gun metalimpeller suitable for submersible pump of capacity 10to 20 HP as per sample. |
| 66 | Supply only stainless shaft sleeves for submersible pumpof capacity 10 to 20 HP as per sample. |
| 67 | Supply only CI intermediate/suction/discharge case suitable for submersible pump 10 to 20 HP capacity and as per sample. |
| 68 | Dismantling the submersible pump motor of 10to 20 HP for re-winding the electric motor with super enamelled copper winding wire of same gauge including impregnated paper, sleevs, lathorised fibre glass, varnish and tape, etc incl transporting to authorized workshop to carry out repair workcomplete all as specified and directed. (Note :- Major spares if required will be paid under respective items mentioned below as supply only) |
| 69 | Supply only Key for motor coupling |
| 70 | Supply only CI clip thrust bearing locking part |
| 71 | Supply only Pin for motor base part |
| 72 | Supply only Pin for thrust bearing |
| 73 | Supply only Cable seal rubber |
| 74 | Supply only Gasket |
| 75 | S&F in replacement, ball bearingas per existing No/size 6201/6202/6203 complete all as specified and directed. |
| 76 | S&F in replacement rubber real insulator of suitable size complete all as specified and directed. |
| 77 | S&F in replacement capacitor of cap 3.15 MFD complete all as specified and directed. |
| 78 | M&L for Taking down and refixing at site ceiling fans 1200mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying , replacement of condenser, ball bearingetc and re-assembling the same including necessary transportation etc complete all as specified and directed. |
| 79 | M&L for Taking down and refixing at site Exhaust fan of 380/450mm sweep including opening of fans and cutting down burnt winding, and re-winding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of condenser, ball bearingetc and re-assembling the same including necessary transportation etc complete forall as specified and directed. |
| 80 | M&L for Taking down and refixing at site Exhaust fan of 230/250mm sweep including opening of fans and cutting down burnt winding, and re-winding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of condenser, ball bearingetc and re-assembling the same including necessary transportation etc complete forall as specified and directed. |
| 81 | Taking out/downwater heater of any type and capacity at different units and servicing of the sameincl cleaning heating element, water pipe, checking of electrical connections, and checking of NRV , safety valve/air release valve etc and refixing of the same after servicing , connecting with inlet and out let water connection and electrical connection andtesting complete all as specified and directed. |
| 82 | S&F in replacement of flexi connection pipe accessory 450 mm for water heater any type/capacity complete all as specified and directed |
| 83 | S&F in replacement of heating element of Tricone type of capacity 1500W in any type of electric water heater complete all as specified and directed. |
| 84 | S&F in replacement of heating element of Cup type of capacity 1500W in any type of electric water heater complete all as specified and directed. |
| 85 | M&L for taking out u/s air conditioner window/ split type in cappacity 1.5 and 2.0 Tonfor replacing to u/s spares /servicing/ carrying out neccessary repairing works/gas re-filling etcin any type/ cap/ make /model including removing all connections safely and refixing after repairing work complete all as directed. |
| 86 | S&F in repair/replacement of thermatically sealed new compressor for air conditioner of 1.5/2.0 TR including connection of all pipe line & changing of refrigerant and testing complete all as specified and directed by Engr-in-charge. |
| 87 | Supply & charging only of refrigerant R-22 to Air conditioner of any type, make and capacity complete all as specified and as directed. |
| 88 | Supply & fixing PCB card suitable for AC any type or size in replacementcomplete all as specified and directed. |
| 89 | S&F in-repair ofElectric fan motor, AC 230 volt, single phase with recommended RPM etc suitable for AC complete all as specified and directed. |
| 90 | S&F in-repair of starting capacitor 100-120 MFD for AC any type of capacity 1.5/2.0 TR complete all as specified and directed. |
| 91 | S&F in-repair of running capacitor 45 MFD for AC any type of capacity 1.5/2.0 TR complete all as specified and directed. |
| 92 | S&F in-repair of relay for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 93 | S&F in-repair of over load protector for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 94 | S&F in Repair/Replacement of condensor for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 95 | S&F in Repair/Replacement of capillarytube set for AC of of capacity 1.5/2.0 TR complete all as specified and directed. |
| 96 | S&F in Repair/Replacement of cooling coil for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 97 | S&F in Repair/Replacement of selecter switch for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 98 | S&F in Repair/Replacement of thermostat for AC of capacity 1.5/2.0 TR complete all as specified and directed. |
| 99 | S&F in-repair of indoor wall mounting unit of split type air conditioners electric driven single Phase of capacity of 1.5TR with minimum 3 star ratingEER 3.2, noise Level 39 DB complete all as specified and directed. Make- Voltas/LG/ Sumsang |
| 100 | S&F in repair/replacement of thermatically sealed new compressor for water cooler of 40/80 ltr/hr cooling capacityincluding connection of all pipe line and testing complete all as specified and directed. |
| 101 | Supply and charging only of suitable refrigerant gas to water cooler of any type, make and capacity complete all as specified and directed. |
| 102 | S&F in repair/replacement of starting capacitor 80/100 MFD for water cooler 40/80 ltr cooling capacity complete all as specified and directed. |
| 103 | S&F in repair/replacement of running capacitor 10 MFD for water cooler 40/80 ltr cooling capacity complete all as specified and directed. |
| 104 | S&F in-repair of thermostate for water cooler of any type & capacity complete all as specified and directed. |
| 105 | S&F in-repair of float valve set for water cooler of any type & capacity complete all as specified and directed. |
| 106 | Repair and Replacement of fan motor for water cooler of40/80 cooling capacitycomplete all as specified and directed. |
| 107 | S&F in repair/replacement of thermatically sealed new compressor for refrigerator of capacity 320 ltr including connection of all pipe line and testing complete all as specified and directed by Engr-in-charge. |
| 108 | Supply and charging only of suitable refrigerant gas to refrigeratorof any type, make and capacity complete all as specified and directed. |
| 109 | S&F in-repair of fan motor for refrigerator 320 ltr cooling capacitycomplete all as specified and directed. |
| 110 | S&F in-repair ofrelay set for Refrigerator ofany capacity upto 320 ltrs complete all as specified and directed. |
| 111 | S&F in-repair of chiller tray for Refrigerator any type any capacitycomplete all as specified and directed. |
| 112 | S&F in-repair of vegitable tray for Refrigerator any type any capacitycomplete all as specified and directed. |
| 113 | S&F in-repair of evaporator for Refrigerator any type any capacitycomplete all as specified and directed. |
| 114 | S&F in repair and Replacement of copper tubing 3/16\" forAC any type any capacitycomplete all as specified and directed. |
| 115 | S&F in repair and Replacement of copper tubing 1/4\" forAC any type any capacitycomplete all as specified and directed. |