Tender For Periodical Maintenance And Essential Repairs To Fire Alarm System At Naval Station Karanja
Tender Value
35 Lakhs
Estimated cost
Bid Submission
14 Mar 2025
0 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
karanja → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Periodical Maintenance And Essential Repairs To Fire Alarm System At Naval Station Karanja
BOQ
| Sl. No. | Item Description |
| 1 | Sch\" A\" Part- I (Periodical Maintenance)Material and labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system, including testing on monthly basis in presence of user representative etc including attendingsystem fault on emergency ,preventive measures by replacing minor spares(up to cost Rs 1000/- including GST and other charges) other than mentioned in Schedule \"A\" Part II for fire alarm system installed at Magic Matra building comprising following all as specified and directed by Engr-in-Charge :-(a)08 Zone main control panel with zone card battery charger and 230 V power unit.(b)Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc.(c) All cable connections from main control panel to items (d)Lead acid battery any capacity(e) Electric Hooter |
| 2 | Ditto- all as per serial item No 1.00 here-in-before but for compressor room bldg in EKM complex (Bldg No 784) for 8 Zone main control panel |
| 3 | Ditto- all as per serial item No 1.00 here-in-before but for oxygen workshop bldg in EKM complex (Bldg No 783) for 8 Zone main control panel |
| 4 | Ditto- all as per serial item No 1.00 here-in-before but for Armoury store room at INS Abhimanyu complex for 8 Zone main control panel |
| 5 | Ditto- all as per serial item No 1.00 here-in-before but for Sea Cat workshop bldg in NAD (Karanja) with 8 zone main control panel |
| 6 | Ditto- all as per serial item No 1.00 here-in-before but for Maurya Hanger for 15 Zone main control panel |
| 7 | Ditto- all as per serial item No 1.00 here-in-before but for Harshawardhan Hanger (MRF P-20) for 15 Zone main control panel |
| 8 | Ditto- all as per serial item No 1.00 here-in-before but for Kashmir TP for 8 Zone main control panel |
| 9 | Ditto- all as per serial item No 1.00 here-in-before but for Club TP for 2 loop Addressable type fire alarmcontrol panel |
| 10 | Ditto- all as per serial item No 1.00 here-in-before but for NAD Explosive area Fire Station for 12 Zone main control panel |
| 11 | Ditto- all as per serial item No 1.00 here-in-before but for NADMain Fire Headquarter Non- Explosive area for 12 Zone main control paneland 20 Zone Control Panel |
| 12 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 249/1 ( \"G\" Fueling Points Tunir Area)for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 13 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 747 ( \"New \"O\" Fueling Points Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric sirenand amplifier,addressable Detector, Manual call Point, Hooter. |
| 14 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P-364 ( \"G\" Damp No - 4 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric sirenand amplifier,addressable Detector, Manual call Point, Hooter. |
| 15 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 363 (\"G\"Damp No - 3 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 16 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 365A (\"O\"Damp No - 2 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 17 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 208 ( \"O\"Damp No - 1 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 18 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 741 ( \"G\"Damp No - 2 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 19 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 248 (Old \"O\"Fueling Point 2 Tunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 20 | Ditto- all as per serial item No 1.00 here-in-before but forBldg No P- 746 (Club Fueling PointTunir Area) for 01 loopmain control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier,addressable Detector, Manual call Point, Hooter. |
| 21 | Ditto- all as per serial item No 1.00 here-in-before but forType -IIIAccn , NAD Colonyfor 07 loopmain control panel with electric sirenof 02 Km range and amplifier and microphone. |
| 22 | Ditto- all as per serial item No 1.00 here-in-before but for582 Bldg for 07 Zone main control panel with electric siren of 02 Km range and amplifier and microphone. |
| 23 | Ditto- all as per serial item No 1.00 here-in-before but for Type -II (A Block)Accn , Chunabhatti Area for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone. |
| 24 | Ditto- all as per serial item No 1.00 here-in-before but for NAD Main Gate Non- Explosive areabut for 12 Zone main control paneland 20 Zone Control Panel |
| 25 | Ditto- all as per serial item No 1.00 here-in-before but for Type -II (B Block)Accn , Chunabhatti Areabut for 07 loop main control panel with electric sirenof 02 Km range and amplifier and microphone. |
| 26 | Ditto- all as per serial item No 1.00 here-in-before but for Kakoli Bldg for 12 Zone main control panel. |
| 27 | Ditto- all as per serial item No 1.00 here-in-before but for Kalapi Bldg for 24 Zone main control panel. |
| 28 | Ditto- all as per serial item No 1.00 here-in-before but for Kiran Bldg for 24 Zone main control panel. |
| 29 | Ditto- all as per serial item No 1.00 here-in-before but for Komal Bldgfor 24 Zone main control panel. |
| 30 | Ditto- all as per serial item No 1.00 here-in-before but for Kailash Bldgfor 24 Zone main control panel. |
| 31 | Ditto- all as per serial item No 1.00 here-in-before but for Kesar Bldg for 12 Zone main control panel. |
| 32 | Ditto- all as per serial item No 1.00 here-in-before but for Koyal building for 8 Zone main control panel. |
| 33 | Ditto- all as per serial item No 1.00 here-in-before but for Kalpana buildingfor 8 Zone main control panel. |
| 34 | Ditto- all as per serial item No 1.00 here-in-before but for Kaneri building for 8 Zone main control panel. |
| 35 | Ditto- all as per serial item No 1.00 here-in-before but for Abhimanyu clothing Store building for 4 Zone main control panel. |
| 36 | Ditto- all as per serial item No 1.00 here-in-before but for Derby hanger for Single loop addressable panel. |
| 37 | Ditto- all as per serial item No 1.00 here-in-before but for Sub fire HQ at NAD for 12 Zone conventional panel. |
| 38 | Ditto- all as per serial item No 1.00 here-in-before but for Type III NADfor Single loop addressable panel. |
| 39 | Ditto- all as per serial item No 1.00 here-in-before but for Harpoon process bldg Tunir for Single loop addressable panel. |
| 40 | Ditto- all as per serial item No 1.00 here-in-before but for Chukar Sqdn III for Single loop addressable panel. |
| 41 | Ditto- all as per serial item No 1.00 here-in-before but for COMCEN (SOK) for Single loop addressable panel. |
| 42 | Ditto- all as per serial item No 1.00 here-in-before but for Chariot Hangerfor Single loop addressable panel. |
| 43 | Ditto- all as per serial item No 1.00 here-in-before but for NAD Factory -II Bldg for Single loop addressable panel. |
| 44 | Ditto- all as per serial item No 1.00 here-in-before but for Narmada Bldg for Single loop addressable panel. |
| 45 | Ditto- all as per serial item No 1.00 here-in-before but for 140 DSC pers Md Accn (Sangam, Zhelam and Yamuna) Bldg for Single loop addressable panel. |
| 46 | Notes for Serial item Nos 1.00 to 45.00 :- (i) Cost of Minor spare parts replaced other than listed in Sch \"A\" Part II shall be deemed to be included in the rate quoted by the contractor.(ii) Testing kit (Solo Smoke and heat detector kit) will be provided by the MES for testing and will be submitted to the department after the testing. |
| 47 | Sch \"\"A\"\" Part-II (ESSENTIAL REPAIRS)Excavation in trenchesnot exc 1.5 meter wide and not exc 1.5 meter depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed by Engr-in-Charge. |
| 48 | Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed by Engr-in-Charge. |
| 49 | Removing excavated soil not exc 50 metres and depositing where directed at a level notexc 1.5 metres above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 50 | Material and labour for sand cushioning with dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming complete all as specified and directed by Engr-in-Charge. |
| 51 | Supply & laying un-reinforced precast concrete cable cover with embossing of cable size and capacity class LV type 1, flat size 250mm x 150mmx 40 mm complete all as specified and directed by Engr-in-Charge. |
| 52 | Supply & fixin replacement manual call pointconventional type surface mounting type of standard size with alarm raising push button, plastic coated glass elementsuitable for conventional type fire alarm system etc complete all as specified and directed by Engr-in-Charge. |
| 53 | Supply & fix in replacement smoke detector confirming to E- 54.7 standard of size 100mm dia, height 56mm suitable to work on 24V DC (12 V DC - 28 V DC) fixed with LED made out of flame retardant plastic confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply & fix in replacementheat detector automatic reset type (class air series 65) complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply and fix in replacement 1.5 sqmm 02 core armoured copper conductor cable ISI marked complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply and fix in replacement 1.5 sqmm 04 core armoured copper conductor cable ISI marked complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply only lead acid battery 12V/7AH capacity (maintenance free) complete all as specified and directed by Engr-in-Charge. |
| 58 | Supply & fix in repair fire alarm hooter with speaker suitable for PA system complete all as specified and directed by Engr-in-Charge. |
| 59 | Supply and Fix fire alarm sounders/sirens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 dB to 120 dB measured at 1.5 meter with sound output variation of +5 dB of 3500 m range complete all as specified and directed by Engr-in-Charge. |
| 60 | Supply and fix in Repairs ZoneCardSuitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge. |
| 61 | Supply and fix in Repairs Power Supply CardSuitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge. |
| 62 | Supply and fix in Repairs Control Monitor CardSuitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge. |
| 63 | Supply and fix in Repairs Transformer unitSuitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge. |
| 64 | Supply & fix in replacement of complete mother board suitable forconventional type fire alarm panel board confirming to fire protection standard all as specified and directed by Engr -in- Charge. |
| 65 | Supply & fix in replacement multisensorwith heat and smoke combination suitable for Addressable type fire alarm panel board working on 24V DC (12 V DC - 28 V DC), made out of flame retardant plastic confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. . |
| 66 | Supply & fix in replacement Manual Call Point suitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. |
| 67 | Supply & fix in replacement Power Supply SMPSsuitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply & fix in replacement Single Loop Card suitable forAddressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply & fix in replacement of complete mother board suitable forAddressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. |
| 70 | Taking down unserviceableconventional type fire alarm control panel from existing position and supply, testing and install newmicroprocessortype fire alarm control panel of 8 zone to work on single phase AC supply 50 Hz fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiringwith suitable copper conductor cable Form panel to floor level manual call point and upto smoke/ heat detector if required all as specified and directed by Engineer-in-Charge. |
| 71 | Taking down unserviceableconventional type fire alarm control panel from existing position and supply, testing and install newmicroprocessortype fire alarm control panel of 12 zone to work on single phase AC supply 50 Hz fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiringwith suitable copper conductor cable Form panel to floor level manual call point and upto smoke/ heat detector if required all as specified and directed by Engineer-in-Charge. |
| 72 | Taking down unserviceableAddressable type fire alarm control panel from existing position and supply, testing and install newAddressable type fire alarm control panelcomplying with BS EN 54, single loop, Panel of Capacity from 99 detector & 99 modules up to 200to work on single phase 50 Hz fabricated out of CRCA sheet steel as per OEM Recommendation including connecting with suitable copper conductor cable Form panel to floor/ Roof level manual call point and upto smoke/ heat detector all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fix in replacement of control module forAddressable type fire alarm panel confirming to fire protection standard all as specified and directed by Engr -in- Charge. |
| 74 | Supply and fix in replacement of monitor module forAddressable type fire alarm panel confirming to fire protection standard all as specified and directed by Engr -in- Charge. |
AI Tender Summary
Tender Timeline
Feb 21, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedMar 14, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 17, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender