Science and Technology Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47878041

Tender For Annual Maintenance Contract Of All Lab Buildings Of Iip.(Electrical Works) 2025-26.

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
23.69 Lakhs
Estimated cost
Bid Submission
17 Mar 2025
0 days left
EMD
47400
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For ANNUAL MAINTENANCE CONTRACT Of All Lab Buildings Of Iip.(Electrical Works) 2025-26.-- 1 wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 2 Group-C 3 Wiring for circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required 4 2x1.5 sq mm + 1x1.5 sq mm earth wire 5 2x2.5 sq mm + 1x2.5 sq mm earth wire 6 2x4 sq mm +1x4 sq mm earth wire 7 2x6 sq mm + 1x6 sq mm earth wire 8 4x4 sq mm + 2x4 sq mm earth wire 9 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 3 X 1.5 sq mm 11 3 x2.5 sq mm 12 3 x 4 sq mm 13 3 x 6 sq m 14 supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed/ PVC conduit as required. 15 2 pair 16 Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 17 20 mm 18 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 19 20 mm 20 25 mm 21 Supplying and fixing metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required. 22 100 mmx 100 mmx 60 mm deep 23 180 mmx 100 mmx 60 mm deep 24 200 mmx 125 mmx 60 mm deep 25 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required. 26 5/6 amps switch 27 15/ 16 amps switch 28 3 pin 5/6 amps socket oulet 29 6 pin 15/ 16 amps socket oulet 30 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 31 5/6 amps switch 32 15/ 16 amps switch 33 3 pin 5/6 amps socket oulet 34 6 pin 15/ 16 amps socket oulet 35 Telephone socket outlet 36 Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 37 Supplying and fixingfollowing size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required 38 1 or 2 module (75 mm x 75 mm) 39 3 module (100 mm x 75 mm) 40 6 module (200 mm x 75 mm) 41 8 module (125 mm x 125 mm) 42 12 module (200 mm x 150 mm) 43 Supplying and fixing following metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including providing and fixing 6pin 5A & 15 A socket outlet and 15 A piano type switch, connection, painting etc. as required . 44 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required 45 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required 46 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. 47 Installation,testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types,compelete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq mm FR PVC insulated copper conductor,single core cable and earthing etc. as required. 48 installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required 49 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as requied upto 450 mm . 50 Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes. 51 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. 52 1 run of cable 53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 Nos. 3 pin 5/6 amp. modular socket outlet and 5/6 amps modular switch with connection etc. As required ( for light plug to be used in Non- Residential buildings) 54 Providing and fixing following rating and breaking capacity MCCB in existing cubical panel board including drilling holes in cubical panel, making connections etc as required 55 200 Amp, 25 KA, TP MCCB 56 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer) as required 57 12 way, (4 + 36) double door 58 Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, C curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testingand commissioning etc. As required 59 single pole (Modular Type) 60 Single pole and neutral 61 Double pole 62 Tripple pole 63 Tripple pole and neutral 64 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 65 40 amps 66 63 amps 67 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 68 40 amps 69 63 amps 70 Supplying and fixing DP sheet steel enclosure on surface/Recess alongwith 25/32 Amp. 240 volt c curve DP MCB complete with connection, testing, commissioning et. As required. 71 Supplying and fixing TP sheet steel enclosure on surface/Recess alongwith 16/25/32 Amp. 240 volt c curve TP MCB complete with connection, testing, commissioning et. As required. 72 Supplying nd Fixing 20 A, 240V SPN Industrial type socket outlet, with 2 pole and Earth metal enclosed plug top along with 20 A, C curve SP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 73 Supplying nd Fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and Earth metal enclosed plug top along with 30 A, C curve TP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 74 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME / METAL pipe etc. As required. 75 upto 35 sq mm 76 Above 35 sq mm and upto 95 sq mm 77 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing masonry open duct as required etc. As required. 78 upto 35 sq mm 79 Above 35 sq mm and upto 95 sq mm 80 Laying and fixing of one number PVC inslulated and PVC sheated/ XLPE power cable of 1.1KV grade of following size on wall surface as required. 81 upto 35 sq mm (clamped with 1mm thick saddle) 82 Above 35 sq mm and upto 95 sq mm(clamped with 25x3mm MS flat clamp) 83 Above 95 sq mm and upto 185 sq mm(clamped with 25/40x3mm MS flat clamp) 84 Erection of metalic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) foundtion including exvation and refilling etc. as required. 85 Above 4.5 Meter and uopto 6.5 Meter 86 Providing and making steel pole collar with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) of specified size and shape including form work, plastering if required, quring etc. as required. (Volume of pole/ pipe not to be deducted) 87 Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required. 88 32 mm dia 89 Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bendingshape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required. 90 Dismentaling of pole/ street light standred sturt embedded in cement concrete foundation et. As required. 91 Excavation for cable trenches in soft soil depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soi, refilling with sand or good soil after laying of cable/pipe etc. in layers of 20 cm, ramming watreing and disposal of surplus excavated soil as directed, witinh a lead of 50 meters. 92 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 93 63 mm dia (OD-63 mm & ID-51 mm nominal) 94 Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology base occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site complete as required. 95 Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 96 1 out put per phase suitable for single phase supply 97 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required. 98 Supply of labour for attending day to day complaints complaints of electrical maintenance work for repair and replacement of all electrical accessories in non workingelectrical fittings and fixture (such main boards, fans, geysers switches, sockets, light fittings, motors, starters, street light, energy meters in lab buildings, underground and overhead line distribution network including service main, operation and maintenance 33KV 044KV substation and power house (24 hour round the clock) all other electrical work as assigned by site-incharge. 99 Skilled labour in Electrical trade 100 Unskilled labour in Electrical trade 101 Attending day to day complaints of no light/ non working points / providing temporary connections in IIP lab buildings, hostel & guest house etc as required. 102 Supplying of RJ45 outlet information module in exsiting modular box etc as required. 103 Supplying of Industrial Heavy duty exhaust fan of 380 mm sweep 1400 rpm/Turboforce neo SP, HD suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 104 Supplying ofexhaust fan of 300 mm sweep 1400 rpm/Ventil air sweep suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 105 Supplyingof following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS aluminium conductor steel armoured alumimium cable of 1.1KV grade as required. 106 2 X 16 sqmm 107 Supplying following rating 415/230v C series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required 108 Double pole, 63 amps 109 Tripple pole and neural, 63 amps 110 Supply and fabrication of sheet steel MCB enclosure fitted with din rail for MCB of following rating complete with connections including drilling holes etc as required. 111 Double pole enclosure 112 Four pole enclosure 113 Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required 114 Supply & replacement of 16 Amp. Plug top, 3 pin with indigator etc. as required 115 Supply & replacement of 6 Amp. Plug top, 3 pin with indigator etc. as required. 116 supply of following Decorative MIRROR LIGHT 20 W with smart, contemporary design of mirror light . The design is a harmonious blend of curves and angles with frame and inbuilt electronic driver & led luminare etc. as required. 117 20W LED, 6500 K luminaries with tube rod. 118 Supplying of following General purpose industrial compact batten suitable for single or twin LED Tube light with integral LED driver, available in single / double side connection options with all as required. Fixture size: (LxWxH) in (1233x36x46) mm (for 1x22 W), (1233x71x46) mm (for 2x22 W) 119 1 X 4 X 22W LED batten 120 2 X 4 X 22W LED batten 121 Supplying of following high efficiency LED tube rod lamps LED luminaire in existing fitting fixture with connection etc. as required. 122 4 X 20W LED luminaries tube rod. 123 supply of indoor recess/ surface 600X600mm (2X2) LED luminaire 36 Watt, 6500 k with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 124 Supplying of 25 Watt, 6500K new generation LED post of lanturn light luminare IP 65, energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium lad scape luminaire with high power LEDs as light souce. Clear cover offers bright illumination for different application. (Havells/ Wipro/ Philiphs/ c&s). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 125 S/R of following Watt LED strret luminaire, New genration energy savin and enviornmental friendly long life LED street light made uo of pressure die cast aluminium housing with high efficiency LED s lighting source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact Resistance of IK07. (Bajaj/ Havells/Philiphs/WIPRO). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 126 30 W led luminaire 127 Supplying of Surface/Recess Mounting LED Panel fitting fixture 15 W( 1X 1), Elegantly designed sleek recessed mounted pressure die- cast alumium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and indepndent elctronic LED driver with connection all etc as required. The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 128 Supplying and drawing folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required. 129 2x6sq mm 130 Supplying of Wall fan of 400 mm sweep, 5 STAR ,energy saving, decorative swing model( off white) suitable for 230 V, single phase, 50 Hz supply including all etc…as required. (Havells/Bajaj/Usha).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 131 Supplying of 50 W turbo LED FLOODLIGHT luminaure, Energy saving, enviornmental friendly, long life, one desig for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highliting architectural features or area lighting. also suitable to rough services/ installations.( Bajaj/ Philiphs/Havells/Wipro).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 132 Providing 9 watt retrofit LED bulbs for guest house etc…as required. 133 Supply of GI electrical pole straight pole of overall length upto 6 meter having two steps and dimensions of 80 mm x 60 mm and pole thickness is 3.65 mm x 3.25 mm for fixing street light complete with M.S base plate having 6.00 mm thickness and with one meter welded tubalar bracket for mounting light fixture all etc. as required. (Detailed pole structure will be as per drawing and aproved by Engineer-in-charge before its dispatch from factory to site).

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 04-Mar-2025 Date Corrigundum Date 17-Mar-2025

BOQ

Name of Work:- AMC of Lab Buildings of IIP.(Electrical Works)2025-26
Sl. No. Item Description
1wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
2Group-C
3Wiring for circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required
42x1.5 sq mm + 1x1.5 sq mm earth wire
52x2.5 sq mm + 1x2.5 sq mm earth wire
62x4 sq mm +1x4 sq mm earth wire
72x6 sq mm + 1x6 sq mm earth wire
84x4 sq mm + 2x4 sq mm earth wire
9Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
103 X 1.5 sq mm
113 x2.5 sq mm
123 x 4 sq mm
133 x 6 sq m
14supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed/ PVC conduit as required.
152 pair
16Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required.
1720 mm
18Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required.
1920 mm
2025 mm
21Supplying and fixing metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required.
22100 mmx 100 mmx 60 mm deep
23180 mmx 100 mmx 60 mm deep
24200 mmx 125 mmx 60 mm deep
25Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required.
265/6 amps switch
2715/ 16 amps switch
283 pin 5/6 amps socket oulet
296 pin 15/ 16 amps socket oulet
30Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
315/6 amps switch
3215/ 16 amps switch
333 pin 5/6 amps socket oulet
346 pin 15/ 16 amps socket oulet
35Telephone socket outlet
36Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
37Supplying and fixingfollowing size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required
381 or 2 module (75 mm x 75 mm)
393 module (100 mm x 75 mm)
406 module (200 mm x 75 mm)
418 module (125 mm x 125 mm)
4212 module (200 mm x 150 mm)
43Supplying and fixing following metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including providing and fixing 6pin 5A & 15 A socket outlet and 15 A piano type switch, connection, painting etc. as required .
44Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required
45Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required
46Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
47Installation,testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types,compelete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq mm FR PVC insulated copper conductor,single core cable and earthing etc. as required.
48installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required
49Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as requied upto 450 mm .
50Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes.
51Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required.
521 run of cable
53Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 Nos. 3 pin 5/6 amp. modular socket outlet and 5/6 amps modular switch with connection etc. As required ( for light plug to be used in Non- Residential buildings)
54Providing and fixing following rating and breaking capacity MCCB in existing cubical panel board including drilling holes in cubical panel, making connections etc as required
55200 Amp, 25 KA, TP MCCB
56Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer) as required
5712 way, (4 + 36) double door
58Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, \"C\" curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testingand commissioning etc. As required
59single pole (Modular Type)
60Single pole and neutral
61Double pole
62Tripple pole
63Tripple pole and neutral
64supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required.
6540 amps
6663 amps
67supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required.
6840 amps
6963 amps
70Supplying and fixing DP sheet steel enclosure on surface/Recess alongwith 25/32 Amp. 240 volt \" c\" curve DP MCB complete with connection, testing, commissioning et. As required.
71Supplying and fixing TP sheet steel enclosure on surface/Recess alongwith 16/25/32 Amp. 240 volt \" c\" curve TP MCB complete with connection, testing, commissioning et. As required.
72Supplying nd Fixing 20 A, 240V SPN Industrial type socket outlet, with 2 pole and Earth metal enclosed plug top along with 20 A, \" C\" curve SP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required.
73Supplying nd Fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and Earth metal enclosed plug top along with 30 A, \" C\" curve TP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required.
74Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME / METAL pipe etc. As required.
75upto 35 sq mm
76Above 35 sq mm and upto 95 sq mm
77Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing masonry open duct as required etc. As required.
78upto 35 sq mm
79Above 35 sq mm and upto 95 sq mm
80Laying and fixing of one number PVC inslulated and PVC sheated/ XLPE power cable of 1.1KV grade of following size on wall surface as required.
81upto 35 sq mm (clamped with 1mm thick saddle)
82Above 35 sq mm and upto 95 sq mm(clamped with 25x3mm MS flat clamp)
83Above 95 sq mm and upto 185 sq mm(clamped with 25/40x3mm MS flat clamp)
84Erection of metalic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) foundtion including exvation and refilling etc. as required.
85Above 4.5 Meter and uopto 6.5 Meter
86Providing and making steel pole collar with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) of specified size and shape including form work, plastering if required, quring etc. as required. (Volume of pole/ pipe not to be deducted)
87Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required.
8832 mm dia
89Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bendingshape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required.
90Dismentaling of pole/ street light standred sturt embedded in cement concrete foundation et. As required.
91Excavation for cable trenches in soft soil depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soi, refilling with sand or good soil after laying of cable/pipe etc. in layers of 20 cm, ramming watreing and disposal of surplus excavated soil as directed, witinh a lead of 50 meters.
92Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
9363 mm dia (OD-63 mm & ID-51 mm nominal)
94Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology base occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site complete as required.
95Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
961 out put per phase suitable for single phase supply
97Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required.
98Supply of labour for attending day to day complaints complaints of electrical maintenance work for repair and replacement of all electrical accessories in non workingelectrical fittings and fixture (such main boards, fans, geysers switches, sockets, light fittings, motors, starters, street light, energy meters in lab buildings, underground and overhead line distribution network including service main, operation and maintenance 33KV 044KV substation and power house (24 hour round the clock) all other electrical work as assigned by site-incharge.
99Skilled labour in Electrical trade
100Unskilled labour in Electrical trade
101Attending day to day complaints of no light/ non working points / providing temporary connections in IIP lab buildings, hostel & guest house etc as required.
102Supplying of RJ45 outlet information module in exsiting modular box etc as required.
103Supplying of Industrial Heavy duty exhaust fan of 380 mm sweep 1400 rpm/Turboforce neo SP, HD suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
104Supplying ofexhaust fan of 300 mm sweep 1400 rpm/Ventil air sweep suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
105Supplyingof following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS aluminium conductor steel armoured alumimium cable of 1.1KV grade as required.
1062 X 16 sqmm
107Supplying following rating 415/230v C series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required
108Double pole, 63 amps
109Tripple pole and neural, 63 amps
110Supply and fabrication of sheet steel MCB enclosure fitted with din rail for MCB of following rating complete with connections including drilling holes etc as required.
111Double pole enclosure
112Four pole enclosure
113Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required
114Supply & replacement of 16 Amp. Plug top, 3 pin with indigator etc. as required
115Supply & replacement of 6 Amp. Plug top, 3 pin with indigator etc. as required.
116supply of following Decorative MIRROR LIGHT 20 W with smart, contemporary design of mirror light . The design is a harmonious blend of curves and angles with frame and inbuilt electronic driver & led luminare etc. as required.
11720W LED, 6500 K luminaries with tube rod.
118Supplying of following General purpose industrial compact batten suitable for single or twin LED Tube light with integral LED driver, available in single / double side connection options with all as required. Fixture size: (LxWxH) in (1233x36x46) mm (for 1x22 W), (1233x71x46) mm (for 2x22 W)
1191 X 4\" X 22W LED batten
1202 X 4\" X 22W LED batten
121Supplying of following high efficiency LED tube rod lamps LED luminaire in existing fitting fixture with connection etc. as required.
1224\" X 20W LED luminaries tube rod.
123supply of indoor recess/ surface 600X600mm (2\"X2\") LED luminaire 36 Watt, 6500 k with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
124Supplying of 25 Watt, 6500K new generation LED post of lanturn light luminare IP 65, energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium lad scape luminaire with high power LEDs as light souce. Clear cover offers bright illumination for different application. (Havells/ Wipro/ Philiphs/ c&s). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
125S/R of following Watt LED strret luminaire, New genration energy savin and enviornmental friendly long life LED street light made uo of pressure die cast aluminium housing with high efficiency LED s lighting source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact Resistance of IK07. (Bajaj/ Havells/Philiphs/WIPRO). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
12630 W led luminaire
127Supplying of Surface/Recess Mounting LED Panel fitting fixture 15 W( 1\"X 1\"), Elegantly designed sleek recessed mounted pressure die- cast alumium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and indepndent elctronic LED driver with connection all etc as required. The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
128Supplying and drawing folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required.
1292x6sq mm
130Supplying of Wall fan of 400 mm sweep, 5 STAR ,energy saving, decorative swing model( off white) suitable for 230 V, single phase, 50 Hz supply including all etc…as required. (Havells/Bajaj/Usha).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
131Supplying of 50 W turbo LED FLOODLIGHT luminaure, Energy saving, enviornmental friendly, long life, one desig for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highliting architectural features or area lighting. also suitable to rough services/ installations.( Bajaj/ Philiphs/Havells/Wipro).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
132Providing 9 watt retrofit LED bulbs for guest house etc…as required.
133Supply of GI electrical pole straight pole of overall length upto 6 meter having two steps and dimensions of 80 mm x 60 mm and pole thickness is 3.65 mm x 3.25 mm for fixing street light complete with M.S base plate having 6.00 mm thickness and with one meter welded tubalar bracket for mounting light fixture all etc. as required. (Detailed pole structure will be as per drawing and aproved by Engineer-in-charge before its dispatch from factory to site).

AI Tender Summary

OUR REF NO 47878041
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.69 Lakhs
LAST DATE 17-03-2025
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender For ANNUAL MAINTENANCE CONTRACT Of All Lab Buildings Of Iip.(Electrical Works) 2025-26.-- 1 wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 2 Group-C 3 Wiring for circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required 4 2x1.5 sq mm + 1x1.5 sq mm earth wire 5 2x2.5 sq mm + 1x2.5 sq mm earth wire 6 2x4 sq mm +1x4 sq mm earth wire 7 2x6 sq mm + 1x6 sq mm earth wire 8 4x4 sq mm + 2x4 sq mm earth wire 9 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 3 X 1.5 sq mm 11 3 x2.5 sq mm 12 3 x 4 sq mm 13 3 x 6 sq m 14 supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed/ PVC conduit as required. 15 2 pair 16 Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 17 20 mm 18 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 19 20 mm 20 25 mm 21 Supplying and fixing metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required. 22 100 mmx 100 mmx 60 mm deep 23 180 mmx 100 mmx 60 mm deep 24 200 mmx 125 mmx 60 mm deep 25 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required. 26 5/6 amps switch 27 15/ 16 amps switch 28 3 pin 5/6 amps socket oulet 29 6 pin 15/ 16 amps socket oulet 30 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 31 5/6 amps switch 32 15/ 16 amps switch 33 3 pin 5/6 amps socket oulet 34 6 pin 15/ 16 amps socket oulet 35 Telephone socket outlet 36 Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 37 Supplying and fixingfollowing size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required 38 1 or 2 module (75 mm x 75 mm) 39 3 module (100 mm x 75 mm) 40 6 module (200 mm x 75 mm) 41 8 module (125 mm x 125 mm) 42 12 module (200 mm x 150 mm) 43 Supplying and fixing following metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including providing and fixing 6pin 5A & 15 A socket outlet and 15 A piano type switch, connection, painting etc. as required . 44 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required 45 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required 46 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. 47 Installation,testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types,compelete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq mm FR PVC insulated copper conductor,single core cable and earthing etc. as required. 48 installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required 49 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as requied upto 450 mm . 50 Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes. 51 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. 52 1 run of cable 53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 Nos. 3 pin 5/6 amp. modular socket outlet and 5/6 amps modular switch with connection etc. As required ( for light plug to be used in Non- Residential buildings) 54 Providing and fixing following rating and breaking capacity MCCB in existing cubical panel board including drilling holes in cubical panel, making connections etc as required 55 200 Amp, 25 KA, TP MCCB 56 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer) as required 57 12 way, (4 + 36) double door 58 Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, C curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testingand commissioning etc. As required 59 single pole (Modular Type) 60 Single pole and neutral 61 Double pole 62 Tripple pole 63 Tripple pole and neutral 64 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 65 40 amps 66 63 amps 67 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 68 40 amps 69 63 amps 70 Supplying and fixing DP sheet steel enclosure on surface/Recess alongwith 25/32 Amp. 240 volt c curve DP MCB complete with connection, testing, commissioning et. As required. 71 Supplying and fixing TP sheet steel enclosure on surface/Recess alongwith 16/25/32 Amp. 240 volt c curve TP MCB complete with connection, testing, commissioning et. As required. 72 Supplying nd Fixing 20 A, 240V SPN Industrial type socket outlet, with 2 pole and Earth metal enclosed plug top along with 20 A, C curve SP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 73 Supplying nd Fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and Earth metal enclosed plug top along with 30 A, C curve TP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 74 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME / METAL pipe etc. As required. 75 upto 35 sq mm 76 Above 35 sq mm and upto 95 sq mm 77 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing masonry open duct as required etc. As required. 78 upto 35 sq mm 79 Above 35 sq mm and upto 95 sq mm 80 Laying and fixing of one number PVC inslulated and PVC sheated/ XLPE power cable of 1.1KV grade of following size on wall surface as required. 81 upto 35 sq mm (clamped with 1mm thick saddle) 82 Above 35 sq mm and upto 95 sq mm(clamped with 25x3mm MS flat clamp) 83 Above 95 sq mm and upto 185 sq mm(clamped with 25/40x3mm MS flat clamp) 84 Erection of metalic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) foundtion including exvation and refilling etc. as required. 85 Above 4.5 Meter and uopto 6.5 Meter 86 Providing and making steel pole collar with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) of specified size and shape including form work, plastering if required, quring etc. as required. (Volume of pole/ pipe not to be deducted) 87 Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required. 88 32 mm dia 89 Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bendingshape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required. 90 Dismentaling of pole/ street light standred sturt embedded in cement concrete foundation et. As required. 91 Excavation for cable trenches in soft soil depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soi, refilling with sand or good soil after laying of cable/pipe etc. in layers of 20 cm, ramming watreing and disposal of surplus excavated soil as directed, witinh a lead of 50 meters. 92 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 93 63 mm dia (OD-63 mm & ID-51 mm nominal) 94 Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology base occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site complete as required. 95 Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 96 1 out put per phase suitable for single phase supply 97 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required. 98 Supply of labour for attending day to day complaints complaints of electrical maintenance work for repair and replacement of all electrical accessories in non workingelectrical fittings and fixture (such main boards, fans, geysers switches, sockets, light fittings, motors, starters, street light, energy meters in lab buildings, underground and overhead line distribution network including service main, operation and maintenance 33KV 044KV substation and power house (24 hour round the clock) all other electrical work as assigned by site-incharge. 99 Skilled labour in Electrical trade 100 Unskilled labour in Electrical trade 101 Attending day to day complaints of no light/ non working points / providing temporary connections in IIP lab buildings, hostel & guest house etc as required. 102 Supplying of RJ45 outlet information module in exsiting modular box etc as required. 103 Supplying of Industrial Heavy duty exhaust fan of 380 mm sweep 1400 rpm/Turboforce neo SP, HD suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 104 Supplying ofexhaust fan of 300 mm sweep 1400 rpm/Ventil air sweep suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 105 Supplyingof following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS aluminium conductor steel armoured alumimium cable of 1.1KV grade as required. 106 2 X 16 sqmm 107 Supplying following rating 415/230v C series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required 108 Double pole, 63 amps 109 Tripple pole and neural, 63 amps 110 Supply and fabrication of sheet steel MCB enclosure fitted with din rail for MCB of following rating complete with connections including drilling holes etc as required. 111 Double pole enclosure 112 Four pole enclosure 113 Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required 114 Supply & replacement of 16 Amp. Plug top, 3 pin with indigator etc. as required 115 Supply & replacement of 6 Amp. Plug top, 3 pin with indigator etc. as required. 116 supply of following Decorative MIRROR LIGHT 20 W with smart, contemporary design of mirror light . The design is a harmonious blend of curves and angles with frame and inbuilt electronic driver & led luminare etc. as required. 117 20W LED, 6500 K luminaries with tube rod. 118 Supplying of following General purpose industrial compact batten suitable for single or twin LED Tube light with integral LED driver, available in single / double side connection options with all as required. Fixture size: (LxWxH) in (1233x36x46) mm (for 1x22 W), (1233x71x46) mm (for 2x22 W) 119 1 X 4 X 22W LED batten 120 2 X 4 X 22W LED batten 121 Supplying of following high efficiency LED tube rod lamps LED luminaire in existing fitting fixture with connection etc. as required. 122 4 X 20W LED luminaries tube rod. 123 supply of indoor recess/ surface 600X600mm (2X2) LED luminaire 36 Watt, 6500 k with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 124 Supplying of 25 Watt, 6500K new generation LED post of lanturn light luminare IP 65, energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium lad scape luminaire with high power LEDs as light souce. Clear cover offers bright illumination for different application. (Havells/ Wipro/ Philiphs/ c&s). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 125 S/R of following Watt LED strret luminaire, New genration energy savin and enviornmental friendly long life LED street light made uo of pressure die cast aluminium housing with high efficiency LED s lighting source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact Resistance of IK07. (Bajaj/ Havells/Philiphs/WIPRO). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 126 30 W led luminaire 127 Supplying of Surface/Recess Mounting LED Panel fitting fixture 15 W( 1X 1), Elegantly designed sleek recessed mounted pressure die- cast alumium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and indepndent elctronic LED driver with connection all etc as required. The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 128 Supplying and drawing folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required. 129 2x6sq mm 130 Supplying of Wall fan of 400 mm sweep, 5 STAR ,energy saving, decorative swing model( off white) suitable for 230 V, single phase, 50 Hz supply including all etc…as required. (Havells/Bajaj/Usha).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 131 Supplying of 50 W turbo LED FLOODLIGHT luminaure, Energy saving, enviornmental friendly, long life, one desig for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highliting architectural features or area lighting. also suitable to rough services/ installations.( Bajaj/ Philiphs/Havells/Wipro).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 132 Providing 9 watt retrofit LED bulbs for guest house etc…as required. 133 Supply of GI electrical pole straight pole of overall length upto 6 meter having two steps and dimensions of 80 mm x 60 mm and pole thickness is 3.65 mm x 3.25 mm for fixing street light complete with M.S base plate having 6.00 mm thickness and with one meter welded tubalar bracket for mounting light fixture all etc. as required. (Detailed pole structure will be as per drawing and aproved by Engineer-in-charge before its dispatch from factory to site).
Basic Detail
Tender No IIP/ESD/2/2/2025
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 04 Mar 2025
Submission Date 17 Mar 2025
Open Date 18 Mar 2025
Finance
Tender Value 23.69 Lakhs
Tender Fee 590
EMD 47400
Exemption Not Available
Document List
01f05c17-9d9e-4a58-9247-3c8bfe55ef9e.html
Tender_Document.pdf
BOQ_255334.xls
make0225.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 04, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 17, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 17, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 18, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

01f05c17-9d9e-4a58-9247-3c8bfe55ef9e.html

pdf

Tender_Document.pdf

xls

BOQ_255334.xls

pdf

make0225.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender