| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-02-2025 | Correction in BOQ | Financial Bid | 05-03-2025 |
| Sl. No. | Item Description |
| 1 | SH:- Earth work |
| 2 | Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.) |
| 3 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) Hard soil |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | SH:- Concrete work |
| 6 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 7 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) In foundation & plinth |
| 8 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :b) In wall etc |
| 9 | SH:- Reinforced Concrete work |
| 10 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementM20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 12 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 13 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers bands and facias up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding the 6 mm to give a smooth and even surface but excluding the cost of centering, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 fine sand : 4 stone aggregate 12.5 mm nominal size). |
| 14 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
| 19 | Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls including attached buttresses, pilasters etc. |
| 20 | Centring and shuttering including strutting, propping etc and removal of form work for : c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 21 | Centring and shuttering including strutting, propping etc and removal of form work for : d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 22 | Centring and shuttering including strutting, propping etc and removal of form work for : e) Column, pillars, posts and struts etc. |
| 23 | Centring and shuttering including strutting, propping etc and removal of form work for : f) Stairs (excluding landings) except spiral stair cases. |
| 24 | Centring and shuttering including strutting, propping etc and removal of form work for : g)Vertical and horizontal fins individually or forming box louvers bands and facias. |
| 25 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Mild steel. |
| 26 | SH:- Brick work |
| 27 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 28 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
| 29 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, includingweldingand bolted with special shaped washers etc complete. 3) Electric resistance or induction butt welded tubes |
| 31 | Welding by Electric plant |
| 32 | Synthetic Thatch roof as per company specification with necessary all framework as per direction of the Engineer in Charge |
| 33 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 34 | Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 35 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer\"s specification and direction of Engineer-in-charge.Decorative finish (wood grained finish) |
| 36 | Providing and fixing to existing door frames 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 37 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profil;es having minimum wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of 8 mm dia with countersunk head, comprising of matching polamide PA6 grade sleeve for fixing frame of finished wall as IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer road approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/toughened/laminated double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid seperately.(a)Two track two panels sliding window with aluminium channel for roller track, wool pile, nylon rollers with SS 304 body 1) Using R2 series with frame (40 mm & above) x (40 mm & above) & Sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre) |
| 38 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profil;es having minimum wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of 8 mm dia with countersunk head, comprising of matching polamide PA6 grade sleeve for fixing frame of finished wall as IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer road approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/toughened/laminated double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid seperately.(a)Three track three panels with two glazed and one wire mesh pannel sliding window with aluminium channel for roller track, wool pile, nylon rollers with SS 304 body 1) Using R2 series with frame (40 mm & above) x (40 mm & above) & Sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre)+C49:G49 |
| 39 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profil;es having minimum wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of 8 mm dia with countersunk head, comprising of matching polamide PA6 grade sleeve for fixing frame of finished wall as IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer road approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/toughened/laminated double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid seperately. c) Ventilator casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamk) powder coayed handles. 1) Using R1 series with frame (33 mm & above) x (35 mm & above) & Sash/mullion (33 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 0.90metre) |
| 40 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Float Glass Panes-4mm thick glass panes of weight not less than 10kg/sqm |
| 41 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws., Ornamental Grill |
| 42 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete., a) 300 x 16 mm |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 300x10 mm |
| 44 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm |
| 45 | SH:- Flooring |
| 46 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622 , of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).a) Size of Tile 600 x 600 mm |
| 47 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1) Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent |
| 48 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 49 | Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn. A) 100 mm diameter pipe |
| 50 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. b) 100 mm diameter |
| 51 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand) (A) CI Plain bend, 100 mm diameter pipe |
| 52 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand) (C) CI Plain shoes : 100 mm diameter pipe |
| 53 | SH:- Finishing |
| 54 | 6 mm cement plaster to ceiling 1 : 4 (1 cement : 4 fine sand). |
| 55 | 12 mm cement plaster 1 : 6 (1 cement : 6 fine sand). |
| 56 | 15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 57 | 20 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 58 | Neat cement punning |
| 59 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 60 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 61 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 62 | SH:- Miscelleneous |
| 63 | Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand). |
| 64 | Providing and fixing 40 mm dia GI Pipe outlet in cement mortar 1 : 3 (1 cement : 3 fine sand) including cutting and making good the wall. |
| 65 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 66 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 67 | Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.b) 100 mm dia SW pipes |
| 68 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.b) 100 mm dia SW pipes |
| 69 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 70 | Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design. |
| 71 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 72 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). b) 40 mm nominal bore |
| 73 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). b) 25 mm nominal bore |
| 74 | Providing and fixing Cromium finish bib cock of approved quality of Sona/ Agmeco brand. a)15 mm nominal bore |
| 75 | Providing and fixing Cromium finish stop cock of approved quality of Sona/ Agmeco brand. a) 15 mm nominal bore |
| 76 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) of Hindware make with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 77 | Providing and fixing white vitreous china wash basin with Pedestral of Hindware make with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm Cromium finish Sona/ Agmeco brand pillar taps of heavy quality. |
| 78 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) One urinal basin with 5 Litres CI automatic flushing cistern |
| 79 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 80 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 81 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality). 750 x 20 mm size |
| 82 | Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia |
| 83 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm |
| 84 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm |
| 85 | Providing and fixing Aluminium railing (Heavy duty) with Aluminiumtube & Square Bar etc complete with hand rails. |
| 86 | Providing and fixing Aluminium post round/ square shape 75 mm dia (Heavy duty) for Aluminiumrailing complete with fixing at floor. |
| 87 | Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2etc complete. |
| 88 | Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, 1800mm length (minimum) and 130 mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of second class teak wood of size 20x15 mm in centre of each tile and bottom and top of work height, 40x15mm placed at ends of each tile. The cladding shall be laid over backlayment of 1.00 mm thick expanded poly ethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bomboo wood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge. |
| 89 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint for all heights, as per specifications, drawings and as directed by Engineer-in-Charge |
| 90 | Providing & fixing Acoustic board for wall etc complete as per company specification |
| 91 | Providing & fixing Acoustic Carpet for floor etc complete as per company specification |
| 92 | Providing & Fixing soft velvet Door & window curtain including all accessories etc complete |
| 93 | Providing and fixing 12 mm thick and 150 mm wide pelmet of flat pressed 3 layer particle board (medium density) with 25 mm dia second class teak wood curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. |
| 94 | Providing and fixing 25 mm dia first class Indian teak wood curtain rods with brackets plugs etc wherever required. |
| 95 | Providing & fixingdigital office signboard with all connection etc complete |
| 96 | FIRE FIGHTING |
| 97 | Wet Riser System with Sprinkler |
| 98 | FIRE ALARM SYSTEM |
| 99 | Automatic Fire Alarm System |
| 100 | SERVICES |
| 101 | Internal water supply and sanitary installation. |
| 102 | LIFT FACILITY |
| 103 | Passenger Lift (Bed Lift) Capacity-20 Person ,Speed- 0.75m per second |
| 104 | WATER TANK (RCC ONLY) |
| 105 | Overhead tank upto staging height 20 meters |
| 106 | SH: Compound Wall |
| 107 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. b) Hard Soil |
| 108 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement :4 sand :8 stone agregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 109 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 110 | Reinforced concrete work in foundations, footings bases of column and mass concreteexcluding costof centring, shuttering and reinforcementin : a) M20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 111 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M 20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 112 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M 20 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 113 | Providing and laying up to floor two level RCC string courses, coping bed plates, anchor blocks, plain window sills and the like including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface including centering and shuttering etc but excluding cost of reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 114 | Centring and shuttering including strutting, propping etc and removal of form work for : e) Column, pillars, posts and struts etc. |
| 115 | Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls including attached buttresses, pilasters etc. |
| 116 | Centring and shuttering including strutting, propping etc and removal of form work for : d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 117 | Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel and medium tensile steel bars. |
| 118 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 119 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 120 | 12 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 121 | 15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 122 | P/FixingMS Grill of approved design make of MS angle & MS flat of 20 x 6 mm with applying a coat of red oxide primer etc complete as per direction of Engineer in Charge. |
| 123 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 124 | SH:Pr0viding and fixing MSdouble leaf Gate with pocket Gate including locking arrangement etc complete.and MS Cattle trap as per design and drawing approved by the Eng in charge |
| 125 | SH:- Formation Cutting |
| 126 | Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres) |
| 127 | Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres ) |
| 128 | SH :- GSB-I & CC pavement |
| 129 | Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.) |
| 130 | Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade. |
| 131 | Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401)( For Grade - I materials) |
| 132 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) |
| 133 | 125 Micron Plythene (Providing and fixing 125 micro polythine over sub-base) |
| 134 | Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ) |
| 135 | Add extra cost for carrying of mixed design concrete by Transit Truck Agitator ( 5 cum capacity) |
| 136 | Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete. d) 300 mm dia RCC Pipes (NP2) |
| 137 | SH :- RCC Retaining wall (3.50 mtr Height) |
| 138 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification,including setting out,construction of shoring and bracing,removal of stumps and other deleterious matter,dressing of sides and bottom and backfilling with approved material.) (i) Ordinary soil, (A) Mannual Means, upto 3 m depth |
| 139 | PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) |
| 140 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications Case-I RCC Grade M20, Using concrete mixer |
| 141 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specificationsRCC Grade M20, Height upto 5m Using concrete Mixer |
| 142 | Supplying, fitting and placing Mild steel reinforcement complete in sub-structure as per drawing and Technical Specification |
| 143 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment,wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification |
| 144 | Back filling behind abutment,wing wall and return wall complete as per drawing and Technical specificationGranular material |
| 145 | SH: Slab culvert 1.00 Mtr span - 1 No) |
| 146 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil, Mannual means Up to 3.00 Mtr depth |
| 147 | Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. |
| 148 | Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications A. Stone masonry work in cement mortar |
| 149 | Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical SpecificationsRCC Grade M20, Height upto 5m Using concrete Mixer |
| 150 | Supplying, fitting and placing Mild steel reinforcement complete in sub-structure as per drawing and Technical Specification |
| 151 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications |
| 152 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical SpecificationGranular material |
| 153 | SH:- RCC DRAIN |
| 154 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) (i) Ordinary soil, A) Manual Means (Depth upto 3 m) |
| 155 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone shingle 40 mm nominal size) excluding the cost of centring and shuttering. |
| 156 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 157 | Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 158 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel and medium tensile steel bars. |
| 159 | Carriage |