| 1 | Sub-Head : Dismantling and Demolishing |
| 2 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Sub-Head :Concrete Work |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 6 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Sub-Head : Roofing |
| 8 | Making Khurras 45X45cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm mnominal size ), finished with 12 mm cement palster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement rounding the edges and making and finishing the outlet complete including dismantaling existing Khurra and disposal of the unserviciable material upto lead of 50 Metre |
| 9 | Sub-Head : Waterproofing |
| 10 | Grading roof for water proofing treatment with |
| 11 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 12 | Sub-Head : Finishing |
| 13 | 12 mm cement plaster of mix : |
| 14 | 1:6 (1 cement: 6 coarse sand) |
| 15 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 16 | 1:6 (1 cement: 6 coarse sand) |
| 17 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 18 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 19 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 20 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 22 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 23 | Lettering with synthetic enamel paint of approved brand and manufacture |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 25 | Old work (one or more coats) |
| 26 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 27 | One coat. |
| 28 | Two coats. |
| 29 | White washing with lime to give an even shade : |
| 30 | Old work (two or more coats) . |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 33 | One or more coats on old work. |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 35 | Lettering with synthetic enamel paint of approved brand and manufacture |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 37 | Lettering with synthetic enamel paint of approved brand and manufacture |
| 38 | Sub-Head : Repairs to Buildings |
| 39 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 40 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 41 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 42 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 43 | Sub-Head : Water Supply |
| 44 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 45 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 46 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 47 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 48 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 49 | 15 mm nominal bore with 30 cm length. |
| 50 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 51 | With common burnt clay F.P.S. (non modular) bricks. |
| 52 | Sub-Head : NEWTECHNOLOGIES AND MATERIALS |
| 53 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 54 | 50 mm average thickness |
| 55 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 56 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. |
| 57 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. |
| 58 | Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc. |
| 59 | (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument) |
| 60 | 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 61 | Sub-Head : MARKET RATED ITEMS |
| 62 | Deduct for taking into posession the unserviceable dismantled materials including carriage: |
| 63 | Unserviciable Brass / PVC Bib/stop cocks/pillar tap |
| 64 | Repairing to aluminium door shutter by opening joints, frames if required and cutting the members to required length, providing and fixing aluminium angle cleats & dash fastener, if required , rearranging the pivots etc. for smooth operation of the Aluminium doors as per direction of the Engineer-in-charge. |
| 65 | Engaging labour for cleaning of open surface drains of any size, roof, terrace, chajjas at any floor at any height including all T & P, removal of debrishes, sullage and disposal all complete as per direction of Engineer-in-charge. |
| 66 | Extra for providing and mixing liquid water proofing compound of DR FIXIT PIDIPROOF LW+ or equivalent in cement concrete / plaster work in doses by weight of cement as per manufacturer’s specification. |