| 1 | Approved rate |
| 2 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etcincluding form work etc as required |
| 3 | Providing and fixing following rating and breaking capacity and pole MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required.100Amp, 16 KA, TPMCCB |
| 4 | Providing and fixing following rating and breaking capacity and pole MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required.125Amp,16 KA,TPMCCB |
| 5 | Providing and fixing following rating and breaking capacity and pole MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required.250Amp, 25 KA,TPMCCB |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.Single pole |
| 7 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 8 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 9 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connectionsetc. as required. |
| 10 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group C |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 14 | Supplying and fixing metal box of following sizes (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including paintingetc as required.150 mm X 75 mm X 60 mm deep |
| 15 | Supplying and fixing metal box of following sizes (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 250 mm X 60 mm deep |
| 16 | Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep |
| 17 | Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator8 way, Double door |
| 18 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 starrated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation:B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope,copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control andall remaining accessories including safety pin, nut bolts, washers, temperature rise=75degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC Supply, earthing etc. complete as required. |
| 19 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with1mm thick saddle) |
| 21 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KVgrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp) |
| 22 | Supplying and installing following size of perforated pre-painted M.S. cable trayswithperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mmthickness |
| 23 | Supplying and installing following size of perforated pre-painted M.S. cable trayswithperforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts,painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mmthickness |
| 24 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts,painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mmthickness |
| 25 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts,painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mmthickness |
| 26 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined withconnectors, suspended from the ceiling with M.S. suspenders including bolts &nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mmthickness |
| 27 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joinedwith connectors, suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6mm thickness |
| 28 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joinedwith connectors, suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6mm thickness |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 30 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet |
| 32 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 33 | Providing, laying, testing & commissioning of 'C' class heavy dutyMS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling withsuitable clamp/support frame and painting with two or more coats of synthetic enamelpaint of required shade complete as required :80 mm dia |
| 34 | Supplying, fixing, testing & commissioning of double flanged sluice valve ofrating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked completewith nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes asrequired :300 mm dia |
| 35 | Providing, laying, testing & commissioning of 'C' class heavy dutyMS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling withsuitable clamp/support frame and painting with two or more coats of synthetic enamelpaint of required shade complete as required :150 mm dia |
| 36 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked completewith nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes asrequired :250 mm dia |
| 37 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KVgrade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq.mm (clamped with 25/40x3mm MS flat clamp) |
| 38 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-3.5C*120 sqmm |
| 39 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-4C*16 sqmm |
| 40 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-2C*6 sqmm |
| 41 | P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance upto 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS)complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single poleMCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutrallink duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate ofsuitable size with danger monogram property printed on the cover etc as reqd. asreqd. |
| 42 | supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher(conforming to IS:2171 with cylinder fully charged) |
| 43 | Supply installation testing and commissioning Horizontal centrifugal pump set withnon clog /mf impeller to handle storm/mixed / sewage water with having min.discharge of 800 m3/hr at head min 7 mtr, RPM 750 having suction and delivery size350 mm or 300 mm dia, mounted on a common base frame coupled with Min. 40 HP or suitable rating (IE-2) three phase, TEFC AC, 415 volts, 50 Hz supply electricalMotor energy efficient complete as required. Mounted on a common base frame asCasing CI, Impeller CI, Shaft & sleeve (SS) 40 C 8 complete with coupling guard andfoundation bolts etc. as reqd. |
| 44 | S/I/T/C of fully automatic Auto Transformer Starter will be made-out / fabricatedwith 2mm thick. MS sheet steel, dust & vermin proof, darn & drip-proof, frontoperated, self supported, free standing type Constructions and will be duly spraypainted Synthetic Enamel paint of Light Grey shade 631 of IS:5 and accommodate allswitch-gear items required to meet the technical requirements of MS 50 HP &Adequate rating OH immersed Auto Transformer having Copper winding, class \"E\"insulation with taping 50%, 65% & 80% (01 No.), Adequate rating Power Contactors,Over Load relay, Single Phase Preventer Relay with Under Voltage & Over VoltageOR M suitable (01 No.), Flush mounting type Ammeter 96Sq.mm with SelectorSwitch suitable CT connection (01 No.), Voltmeter 96Sq.mm with Selector Switch(01 No.), Indicating lamp for ON,OFF,TRIP (03 Nos.), Indicating lamp for R,Y,B (03Nos.) without transformers Oil, as follows:(1). Switch Fuse unit 125 A TPN withHandle FN 125 A -01 No. (2). HRC Fuse 125A -3 Nos. (3). Star Contactor coilvoltage 240 AC with 2 No + 2 NC AUX. contacts Block MNX 50-I No. (4). TAPcontactor coil voltage 240 AC with 2 No + 2 NC AUX. contacts Block MNX 80-1No. (5). Line contactor coil voltage 240 AC with 2 No + 2 NC AUX. contacts BlockMNX 80-1 No. (6). Over Load relay range - A CT operated 45 - 75A MNS- 01. No.(7). Current Transformer 15 VA, CL. 1 for Metering 100/5A - 3 No. (8). Push ButtonStart/stop element 22.5mm Ma -2 Nos. (9). Indicating lamps 230V AC Red LEDType - 3 No. (10). MCB 6A IP MO, 10 KA - 1 No. (11). On Delay Timer 0-30 Sec.,Coil Voltage 240V, AC 2AODTS - 3 Nos. (12). Ammeter, 0-100/5a, (100-600A)Sappers Scale 6-Time, 96 Sq.mm with Ammeter Selector switch 0-10015A -1 No.(13). Voltmeter 0-500V, 96 SQHM size with voltage selector switch S96 - 1 No. (14).Single Phase preventer relay with under voltage S2VMR2 -1 no. |
| 45 | S/I/T/C of cubical type control panel board for three phase star delta starter, threeposition selection with auto switch for Mono submersible pumping set of followingrating complete with single phasing preventer in auto, contactor (25Amp), O/L relayTP, MCB, Voltmeter, ammeter, VSS and indication lamp etc. including lamp etc.including connection etc. as required. (a) 10 H.P. rating Submersible Pump Set OverLoad relay (range13-21 Amp) & Contactor (range 25 Amp). |
| 46 | On load change over switch 630 Amp. Open execution type: 2 Nos. (one for DG setand 1 for phase sequence). |
| 47 | SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports,interconnection, erection of switch gears with depth 30 cm to 60 cm and makingprovisions for termination of incoming/ outgoing cables/ bus ducting and makingfoundation etc as required. (Suitable for 400 Amp TP & N) |
| 48 | SITC of APFC Panel duly compartmentalized wall mounted / floor mounted cubicleboard made from 2mm thick CRCA sheet dust & vermin proof duly powder coatedinclusive of suitable size of 4 strip AI. Busbar complete with interconnectionproviding lugs, inter-earthing, painting etc. i/c providing & fixing below notedaccessories;. 1. Suitable Size of INCOMING four pole MCCB, 2. Suitable Size ofAnalog Ammeter with selector switch C.T. \"s etc.- 1 Set, 3. 500 Volt analogVoltmeter with selector switch - 1 set 4. RYB LED type Indication lamps withBackup fuses -1 Set of three., 5. Power factor meter - 1 set ,6. 14 step APFC relay with aux.Contactor and timer - 1 set., 7. Suitable capacity 4 strip AI. Bus- Bar., 8. Requirednumbers of OUT GOINGS with suitable sets & sizes of MCCB compatible to KVARrating of APFC panel for overall maintaining of required P.F. and also confirming tosafe running of complete panel etc., 9. Required set of Push button for START ISTOP., 10. AUTO I MANUAL Selector switch - 1 No. Complete with all requiredaccessories,connections, interconnection etc as required |
| 49 | Providing and fixing of 600 mm sweep Air circulator, complete with blades, jaalworkable on 220/ 240 volts AC supply etc as reqd. |
| 50 | SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die castaluminium housing & toughened glass cover complete with the followingspecification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5%(b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) ProtectionClass- IP-66 |
| 51 | S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonatehousing batten integrated electronic driver prewired with high efficient LEDs with thefollowing:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt>=95 (c)Power Factor >=0.95 |
| 52 | 16 sq. mm lSI marked, FRLS PVC insulated, single core copper conductor cable |
| 53 | Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS: 5424/ 69 Black or Red in 1 M X 2 M of size.25 mm thickness |
| 54 | P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 withrequired nut bolts & packing sheet etc. complete as required of following Dia.- 500 mm, 9.5 mm thick |
| 55 | P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 withrequired nut bolts & packing sheet etc. complete as required of following Dia.- 300 mm, 9.5 mm thick |
| 56 | P & F of M.S. Flange with required nut bolts & packing sheet etc complete asrequired of following Dia:-300 mm (25 mm thickness) |
| 57 | P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete asrequired of following Dia.150 mm (12 mm thickness) |
| 58 | P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete asrequired of following Dia.500 mm (25 mm thickness) |
| 59 | P & F of M.S. Bend with required nut bolts & packing sheet etc complete as requiredof following Dia:-500 mm (10 mm thick),length 1 m |
| 60 | P & F of M.S. Bend with required nut bolts & packing sheet etc complete as requiredof following Dia:-300 mm (8 mm thick),length 0.75 m |
| 61 | Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 300mm |
| 62 | Replacement of swing type Non Return Valve of CI Body with Door, bronze toRubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 80mm |
| 63 | Providing & Fixing of MS Bar Screen made out of MS channel size 4\" x 2\" (100mm x 50 mm) and center covered with MS Flat size 80 x 8 mm duly welded withcenter to center distance 40 mm and back side supporting channel (100 x 50 mm)duly welded. Work also includes complete Bar Screen fixing in the drain with thehelp of heavy crane and complete bar screen duly painted with enamel paint. BarScreen duly fixed in side wall using Mortar, tools and tackles. |
| 64 | Providing & Fixing of MS Bar Screen made out of MS Angle size (75 mm x 75 mm)and center covered with MS Sq bar size 18 mm duly welded with center to centerdistance 35 mm and duly welded. Work also includes complete Bar Screen fixing inthe drain with the help of heavy crane and complete bar screen duly painted withenamel paint. Bar Screen duly fixed in side wall using Mortar, tools and tackles. etccomplete as required. |
| 65 | Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cuttingthreading on both sides etc. ISI marked etc as reqd.32mm(Nominal Bore) |
| 66 | S & F following size of G.I. Socket. as reqd.32mm |
| 67 | S & F following size of G.I. Union. as reqd.32mm |
| 68 | S & F following size of G.I. Elbow. as reqd..32mm |
| 69 | Development of tube well with suitable capacity of air compressor i/c lowering of thenecessary induction pipe or line i/c cost of fuel, hire charges of compressor etc asreqd. The development shall be considered complete when Gravel stop sinking,Discharge ceased to improve and the sand contents are not more than 10 PPM after 20minutes of starting the pump complete as reqd. |
| 70 | SITC of Horizontal type, self priming non clog sewage pump, single stage Pump,with CI Impeller, EN8 shaft & Sleeve, with suitable suction & Delivery LPM 1032 at10 Mtr, Head up to 20 Mtr coupled with 3 phase 1 Induction motor 5 HP, TEFC, 440Volt, 1450 RPM with coupling guard, Base frame with AVM etc complete asrequired. |
| 71 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-3C*10 sqmm |
| 72 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-4C*25 sqmm |
| 73 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KVgrade conforming to IS-7098 of following size:-4C*70 sqmm |
| 74 | P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 withrequired nut bolts & packing sheet etc. complete as required of following Dia.- 350 mm, 9.5 mm thick |
| 75 | P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 withrequired nut bolts & packing sheet etc. complete as required of following Dia.- 250 mm, 9.5 mm thick |
| 76 | P & F of M.S. Flange with required nut bolts & packing sheet etc complete asrequired of following Dia:-250 mm (20 mm thickness) |
| 77 | P & F of M.S. Flange with required nut bolts & packing sheet etc complete asrequired of following Dia:-350 mm (25 mm thickness) |
| 78 | P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete asrequired of following Dia.350 mm (25 mm thickness) |
| 79 | P & F of M.S. Bend with required nut bolts & packing sheet etc complete as requiredof following Dia:-350 mm (8 mm thick),length 0.75 m |
| 80 | P & F of M.S. Bend with required nut bolts & packing sheet etc complete as requiredof following Dia:-250 mm (8 mm thick),length 0.5 m |
| 81 | Replacement of swing type Non Return Valve of CI Body with Door, bronze toRubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 250mm |
| 82 | Replacement of swing type Non Return Valve of CI Body with Door, bronze toRubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 150mm |
| 83 | Supplying, fixing, testing & commissioning of non rising spindle sluice valve of CIbody with wedge bronze ring confirming to IS 14846 and 55, lSI 6603 markedcomplete PN 1. 6 complete as required.150 MM |
| 84 | Supplying, fixing, testing & commissioning of non rising spindle sluice valve of CIbody with wedge bronze ring confirming to IS 14846 and 55, lSI 6603 markedcomplete PN 1. 6 complete as required.80 MM |
| 85 | Dismantling of Electric Pump Sets along with other allied equipments at BP BlockPump house.Dismantling of the following equipment’s / material from the existing pump housewith the help of skilled / unskilled heavy labour, cutting of nut bolts with the help ofgas cutter, all tools and tackles, arrangement of crane for dismantling and shifting thematerial in a safe place as directed by Engg.-In-Charge.For BP Block Pump house1.Disconnection & dismantling of LT cables of main switch, Main LT panel etc.2.03 Nos. 25 HP ATS oil immersed starter i/c disconnection of all incoming andoutgoing cables along with dismantling of phase change over 200 Amp. / 415 V.3.03 Nos. 25 Hp electric pump sets from the foundation, comprising of 25 HPKirloskar make electric motor coupled with 150x26 Kirloskar make MF type pumpmounted on common base frame.4.All MS suction and delivery piping of various size up to 400 mm from the dry sumpi/c suction and delivery valves of all the three pump sets i/c dismantling of all C.I.piping from the wet sump well.5.All dismantled material shall be shifting the material in a safe place as directed byEngg.-In-Charge. |
| 86 | Dismantling of Electric Pump Sets along with other allied equipments at Shakti ViharPump house.Dismantling of the following equipment’s / material from the existing pump housewith the help of skilled / unskilled heavy labour, cutting of nut bolts with the help ofgas cutter, all tools and tackles, arrangement of crane for dismantling and shifting thematerial in a safe place as directed by Engg.-In-Charge.For Shakti Vihar Pump house1.Disconnection & dismantling of LT cables of main switch, Main LT panel etc.2.02 Nos. 25 HP ATS oil immersed starter i/c disconnection of all incoming andoutgoing cables along with dismantling of phase change over 200 Amp. / 415 V.3.02 Nos. 25 Hp electric pump sets from the foundation, comprising of 25 HPKirloskar make electric motor coupled with 150x26 Kirloskar make MF type pumpmounted on common base frame.4.All MS suction and delivery piping of various size up to 300 mm from the dry sumpi/c suction and delivery valves of all the three pump sets i/c dismantling of all C.I.piping from the wet sump well.5.All dismantled material shall be shifting the material in a safe place as directed byEngg.-In-Charge. |
| 87 | Providing & Fixing Auto transformer starter 50HP (without oil) conforming to ISSspecification, tapping provided from 40, 60 & 80% of line voltage fitted with fix andmoving contacts ETP grade copper to provide long life fitted with 3 magneticoverload relay of dash pot type adjustable from full load to twice of full load earthingterminal provided suitable for places where motor starting load is high etc. completeas required. |
| 88 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |