Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #47867143

Tender For Construction Of 25 Kl Rcc Oht And Staging 15M, Boring And Water Line At Rural Stadium Gram Donkhar, Tahsil Bansgaon Gorakhpur

Issued by Boards / Undertakings / PSU · bansgaon, Uttar Pradesh
Tender Value
30.60 Lakhs
Estimated cost
Bid Submission
06 Mar 2025
0 days left
EMD
62000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bansgaon → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Construction Of 25 Kl Rcc Oht And Staging 15M, Boring And Water Line At Rural Stadium Gram Donkhar, Tahsil Bansgaon Gorakhpur

BOQ

Name of Work:-Construction of 25 KL R.C.C. O.H.T & Staging 15 M, Boring and Water Line at Rural Stadium Gram Donkhar, tahsil Bansgaon Gorakhpur
Sl. No. Item Description
1Design and construction including supply of all materials, labour T&P etc. over head tank of 25.00 Kl capacity over 15.00 m RCC staging measured from ground level to the top of ring beam supporting tank body complete with one meter wise RCC balcony at tank bottom. Complete with one meter wide RCC stair case with one meter height GI Pipe railing on both side over stair case with one meter hight GI Pipe railing on both size over stair case and on top dome and balcony on size made of 2 rows of 20 mm dia GI Pipe medium quality supported on 50x50x6 mm angle iron post placed at suitable interval, supply and fixing of inside of the tank, supply and fixing at top roof 600 mm x 600mm ms manholes cover with locking arrangment supply and fixing of copper lighting conductor with earthing, water level indicator, mosquito proof ventilation red light arrangement at top including proper wiring steel gate enclosure at entrance of the stair case, Hostingm, erecting and jointing CIDF pipes of required diameter for inlet, outle, overflow and wash out desired size 6 mm thick rubber packing, bolts and nuts of standard make and size as per approval of engineer incharge clamps etc, (including supply of CIDF pipes, duck foot bend and bell mouth etc) upto two metre beyond apron 25 mm thick flooring for apron in PCC 1:2:4 laid in paneled over 80 mm thick 1:6:12 C-1 type drain all around the apron construction of wash out over chamber, painting the complete structure with three or more coat of water proofing cement paint (ISI mark of approved make and shade, painting all steel work such as railing, ladders, manhole cover and all pipe with two coats of approved quality enamel paints, ISI mark) over one base coat of primer and including testing of tank for water tightness, (the bearing capacity of soil to be take as actual.(1) Rate for adjustment of cost to be made to regulate the payment for increase or decrease in depth of foundation from 2.00 m below (0.25 METER EXTRA) provided in item No. 01(2) Rate for Adjustment of cost to be made to regulate the payment for increase in height of staging from 18.00m (2 METER EXTRA) as provided in item No 01
2Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia All types of soil 400 mm dia DSR-23.1.1.3
3Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia Rocky strata including Boulders 400 mm dia DSR-23.1.2.3
4Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwedand socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge200 mm nominal size dia having minimum wall thickness 5.40 mm DSR-23.10.3
5Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia DSR-23.11.3
6Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. DSR-23.15.3
7Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :200 mm dia DSR-23.13.3
8Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. DSR-23.14.3
9Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. DSR- 23.8
10Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. DSR-23.12
11Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc 10 sq. mm 2 core PWD Electrical SOR 2018 501 b
12Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects.The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector VVswitches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only Incoming 100 Amp. TPN-1 No Outgoing 63 Amp. TNP-2 Nos.Cat. B. Cubicle Type PWD Electrical SOR 2018 801 a
13Providing,laying,testing&commissioningof ’C’ classheavyduty MSpipeconformingto IS 3589/IS1239includingWelding,fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing thepipeonthewall/ceilingwithsuitableclamp/supportframeand painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia DSR ELECTRICAL 2022 18.7.6
14Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 110 mm clamp DSR 23.14.1
15Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 100 mm diameter DSR 18.31.1.2
16Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) :100 mm dia C.I. Double Flanged Pipe DSR 18.71.1
17Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 Up to 300 mm dia DSR 18.66.1
18S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawin PWD Electrical SOR 2018703
19S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site. PWD Electrical SOR 2018 721
20S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc 16 sqmm x 4 core PWD Electrical SOR 2018 501(1) S
21Supply of 7.5 HP KSB make submersible pump set model BPD 302/4+UAMI 150/6/22-203 (S/D) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition 7.5 HP 6 stage pipe. A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm B - Total Head of pump set 45 m. MR
22Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.MR
23Supply of Steel Wire Rope 1/2\" Size MR
24Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore DSR-18.12.6
25Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore DSR- 18.12.8
26Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)DSR-19.2.1

AI Tender Summary

OUR REF NO 47867143
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 30.60 Lakhs
LAST DATE 06-03-2025
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Construction Of 25 Kl Rcc Oht And Staging 15M, Boring And Water Line At Rural Stadium Gram Donkhar, Tahsil Bansgaon Gorakhpur
Basic Detail
Tender No 179/G-06/05 DATED 13.02.2025
Bidding Type Tender
Location
City bansgaon
State Uttar Pradesh
Key Dates
Publish Date 20 Feb 2025
Submission Date 06 Mar 2025
Open Date 06 Mar 2025
Finance
Tender Value 30.60 Lakhs
Tender Fee 2950
EMD 62000
Exemption Available
Document List
e9e84b8b-dca7-46df-9e3d-855dd094b88b.html
BOQ_1806060.xls
Tendernotice_1.pdf
TENDER_DOCUMENT_OHT_RURAL.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 20, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 06, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 06, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e9e84b8b-dca7-46df-9e3d-855dd094b88b.html

xls

BOQ_1806060.xls

pdf

Tendernotice_1.pdf

pdf

TENDER_DOCUMENT_OHT_RURAL.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders