| 1 | Dismantling and removing and setting aside for credit to contractor steel tubular poleany type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and as directed by Engr-in- Charge. |
| 2 | S&F steel tubular pole 11m long sweged and cast iron base plate, final taper plug, bolt, nuts and screws as specifiedtype 410 SP-55 and applying two coat of aluminium paint over a coat of red oxide primer including preparation ofnew steel surface complete all as specified and as directed by Engineer -in- Charge. Note:- Excavation , earth work and PCC shall bemeasured and paid for separately under relvant item of this BOQ. |
| 3 | S&F steel tubular pole 9m long sweged and cast iron base plate, final taper plug, bolt, nuts and screws as specifiedtype 410 SP-31 and applying two coat of aluminium paint over a coat of red oxide primer including preparation ofnew steel surface complete all as specified and as directed by Engineer -in- Charge. Note:- Excavation , earth work and PCC shall bemeasured and paid for separately under relvant item of this BOQ. |
| 4 | M&L in replacementcross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directedand applying two coat of aluminium paint over a coat of red oxide primer including preparation ofnew steel surface complete all as specified and as directed by Engineer -in- Charge. . |
| 5 | Supply, laying, connecting and testing in replacement XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor for 11KV (Earthed) of followingcross sectional areacomplete. |
| 6 | 3 core, 95 sqmm |
| 7 | 3 core 150 sqmm |
| 8 | 3 core 185 sqmm |
| 9 | S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size 95 sqmm complete all as specified and as directed by Engr-in- Charge. |
| 10 | S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminationjointheat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size 95 sqmm complete all as specified and as directed by Engr-in- Charge. |
| 11 | S&F in repair cable jointing kit for 11 KV (Earthed) grade cable forS&F in repair cable jointing kit for 11 KV (Earthed) grade cable forstraight through jointheat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size 95 sqmm complete all as specified and directed by Engr-in-charge |
| 12 | S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed by Engr-in-charge |
| 13 | S&F in repair cable jointing kit for 11 KV (Earthed) grade cable foroutdoor termination joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed by Engr-in-charge |
| 14 | AS&F in repair cable jointing kit for 11 KV (Earthed) grade cable for straight throughheat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and asdirected by Engr-in-charge |
| 15 | S&F PCC cable route indicators with suitable reinforcement of size 50 X 20 X 10 cm with letter inscribed on both sides as \"MES HT CABLE\"of specified font size not less than 60 mm as directed and mounted on PCC 40x 30x30 cm in PCC M-15 grade (Nominal Mix)using 20mm graded stone aggregate and applying two coats ofcement based paint complete all as specified and as directed by Engr-in-charge |
| 16 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft / loose soil for pole foundation / cable trench / stay assembly etccomplete all as specified and asdirected by Engr-in-charge |
| 17 | Excavating in trenches n.exc 1.5m wide and depth exceeding 1.5 m and not exceeding 3m deepand getting out in hard and densesoil for pole foundation / cable trench / stay assembly etc complete all as specified and asdirected by Engr-in-charge |
| 18 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft disintegrated rock or for road cutting complete all as specified and asdirected by Engr-in-charge. |
| 19 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and asdirected by Engr-in-charge. |
| 20 | Removing the excavated soil to a distancen.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete complete all as specified and as directed by Engr-in- Charge. |
| 21 | M&L for crushed stone grid for cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and as directed by Engr-in- Charge.Note:- Measurement shall be taken after gentling puning. |
| 22 | Supply and laying unreinforced precast concrete cable cover, class HV, Type I flat of size 300mm x 180mm x 40mm all as directed by Engr-in-Charge complete all as specified and as directed by Engr-in- Charge. |
| 23 | S&F in replacement GI tubing light grade of following sizes with all fittings for protection of cablelaid in tranches or fixing on pole , wall with suitable size of MS clamp complete all as specified and as directed by Engr-in- Charge. |
| 24 | 100 mm dia bore |
| 25 | 80 mm dia bore |
| 26 | S&F in replacementHT 11 KV composite polymeric pin insulator grey colour, having shack dia 20mm collar dia 40mm and thickness 5mm including two galvanised iron washers and one galvanised iron nutsuitable for mounting complete all as specified and as directed by Engr-in- Charge. |
| 27 | S&F in replacement HT 11 KV Composite polymeric tension (disc)insulator grey colour having ball and socket type end fittings or long rod insulator complete all as specified and as directed by Engr-in- Charge. |
| 28 | S&F in replacementlightining arrestors expulsion type Class LA complete with all fittings havingdischarge capacity 6.5 Kilo Amp suitable for 11 KV complete all as specified and as directed by Engr-in- Charge. |
| 29 | S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame vertical type complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 50 Amp complete complete all as specified and as directed by Engr-in- Charge. |
| 30 | S&F in replacement gang operated air brake switch triple pole mechanically operated vertical type mounted on polymer insulator & steel frame with operating mechanisam worked from ground level suitable for 11 KV for current rating upto 200 Amp with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handle complete all as specifed by Engineer-in-Charge. Note : Air Brake switch shall consist of three polymer insulators per phase and 9 isolators in all. |
| 31 | M&L for bituminous road cutting to a width of 45cm and depth 30cm for laying of HT cable and making good with PCC M-10 grade (Nomnal Mix) using 20mm grade stone aggregate complete all as specified and as directed by Engr-in- Charge. |
| 32 | M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaning fromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of aluminium paint, retaining & repainting marking on pole & replacement of reflective band of width 4 cm RED-YELLOW-RED alternate coloured 3 numbers complete all as specified and as directed by Engr-in- Charge. |
| 33 | M & L for scrapping existing deteriorated old aluminium paint by hard wire brush and applying a coat aluminium paint on existing 2 pole structure including cross arms, support angles, clamps and any other structural part complete all as specified and as directed by Engr-in- Charge. |
| 34 | M & L for scrapping existing deteriorated old aluminium paint by hard wire brush and applying a coat aluminium paint on existing 6 pole structure including cross arms, support angles, clamps and any other structural part complete all as specified and as directed by Engr-in- Charge. |
| 35 | M & L for scrapping existing deteriorated old aluminium paint by hard wire brush and applying a coat aluminium paint on existing 4 pole structure including cross arms, support angles, clamps and any other structural part complete all as specified and as directed by Engr-in- Charge. |
| 36 | M&L for fault detection in damaged HT/LT UG cable by usingcable fault detector/locator vehicle mountedcomprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc to accuracy of 2 meter forUG cables of any size any typeupto 11 KV incl excavation & Earthwork in any type of stratra to usually inspect/repair the damaged cable when and where required complete all as specified and as directed by Engr-in- Charge.Note :-(i)Compaint will be notified to contractor on mobile phone at any time and contractor is responsible to rectify the fault within 4 hrs after notification, failing which Rs. 500/- per hrs shall be recovered from contractors dues. (ii)Rates included necessary earth work in any type of strata or roadfor opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes. (iii) Cable jointing kit will be measured under relevant item. |
| 37 | M&L for Loose filling with aggregates of broken stone gauge 20 to 40 mm in HT substation yard complete including removal of any debris and vegetation etc complete all as specified and as directed by Engr-in- Charge. |
| 38 | S & F in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and as directed by Engr-in- Charge. |
| 39 | M & L for scrapping existing deteriorated old paint by hard wire brush, painting the existing HT panel by aluminium paint including handles minor parts complete and any other structural partcomplete all as specified and as directed by Engr-in- Charge. |
| 40 | M&L for bore type maintenance free chemical Earthing of bore dia 150mm complete with GI electrode of 40mm bore buried in 3 mtr depth withground enhancing backfill compound (Safe ground) , the compound should be highly conductive, Hygroscopic, non magnetic, non corrosive in nature and should have best moisture retaining quality including necessary returning filling in & removal and pvc pit covercomplete all as specified and as directed by Engr-in- Charge. |
| 41 | M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc complete all as specified and as directed by Engr-in- Charge. |
| 42 | S&F in replacement aluminium conductor, steel reinforced overhead conductors (all sizes) inclbinding wire etc complete all as specified and as directed by Engr-in- Charge. |
| 43 | Demolition of cement concrete unreinforced of any description and in any position not otherwise specially provided for all as directed by Engr-in-Charge |
| 44 | M & L for PCC M-7.5 grade (Nomian Mix)using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed by Engr-in- Charge. |
| 45 | M & L for PCCM-10 grade (Nomian Mix) using 40 mm graded stone aggregate for mass filling of poles etc complete all as specified and as directed by Engr-in- Charge. |
| 46 | M&L for cement concrete as in coping I PCCM-15 grade (Nomian Mix) using 20mm gradedstone aggregateincluding necessary form work complete all as specified and as directed by Engr-in- Charge. |
| 47 | Supply and fix in replacement high voltage shock resistance, anti skid insulating mat as per IS-15652-2006, class C of size 1mx2m x 3 mm thick complete all as specified and as directed by Engr-in- Charge. |
| 48 | S&F in replacement MCCB 4 pole adjustable type 400 Amps with breaking capacity 36 KA including all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 49 | S&F in replacement MCCB 4 pole adjustable type 250 Amps with breaking capacity 36 KA including all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F in replacementMCCB, 3 pole adjustable type 250 Amps with breaking capacity 36 KAincluding all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 51 | S&F in replacementMCCB, 3 pole adjustable type 160 Amps with breaking capacity 36 KAincluding all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 52 | S&F in replacementMCCB, 3 pole adjustable type 125 Amps with breaking capacity 16 KAincluding all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 53 | S&F in replacementMCCB, 3 pole adjustable type 100 Amps with breaking capacity 16 KAincluding all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 54 | S&F in replacementMCCB, 3 pole adjustable type 63 Amps with breaking capacity 16 KAincluding all connected accessories complete all as specified and as directed by Engr-in- Charge. |
| 55 | Supply, install, testing and commissioning in replacement of factory made outdoor type Feeder fillar box of size 1200mm x1200mm x400mm mounted on MS Channel CPRI approved suitable for HT 11 KV grade 3 phase 3 wire system with 09 Nos epoxy insulators and 03 Nos copper bus bar of suitable size and made out of 3.00mm powder coated CRCA sheet having gasketed front hinged split doors with bottom detachable gland plate for upto 3 cable entry/exit of size upto 300 sqmm with suitable size of cadmium plated and nuts, bolts and wshers and incl weatherproof, bottom hole, outdoor triple key weather proof pad lockings. The panel shall be of powder coated smoke grey colour duly marked \"MES HT 11 KV\" complete all as specified and as directed by Engr-in- Charge. |
| 56 | S & F in replacement unsv HT 11 KV bus bar insulator of HT panel complete all as per existing one. |
| 57 | S&F in replacement of glow sign boards of size not less than 6m x 1 m x 0.4 m made of ACP Panel sheet of 3mm thick with Blue backgroundover 40\" x 40\" square tubes with vergeletters made of acryclic sheet white in colour and having LED strip only on letters and MES Logoplaced on angle iron frame duly welded of size 50X50X5.00 mm thick of height not less than 2 mtr including connecting service cable weather proof 4.00 sq mm 2 core from switch board upto 20 mtrcomplete as per sample complete all as specified and as directed by Engr-in- Charge.NOTE : Sample of glow sign board to be got approved by Engr-in-charge/GE before placing the order.. |
| 58 | S&F in replacement galvanised stay strand of size 7/2.50mm suitable for stay assembly complete all as specified and directed. |
| 59 | Taking down burnt out jumpers and M&L for new jumper connection not less than 1.5 Mtr long between bus system to GOD and GOD to DO fuse unit with jumper made of 11 KV aluminum conductor including clamps, crimple, PVC slveeves complete all as specified and as directed by Engr-in- Charge. |
| 60 | M&L for servicing of 11 KV GOD & DO fuse unit of any capacity at different sub stations by means of adjustment, alingment, oiling, greasing, conducting jelly etc including new minor spares such as nuts, bolts, wahsers, male/female contact, fix contract jaw, tinned copper flexible jumper 200/400 A capacity, MS jumper carrier, back connector plate, fixed top, bottom contactfor DO unit including replacement of broken post insulator of GOD & DO complete all as specified and as directed by Engr-in- Charge. |
| 61 | M&L for filtration/dehydration transformer (voltage grade 11/0.433 KV ) indooor/outdoor type, mounted on 2/4 pole structure/plinth/substation at site/work shop by dehydration/filtration plant to achieve dielectric strength of 60 KV at 4 mm gap complete all as specified and as directed by Engr-in- Charge.Note :-i) Contractor is responsible to arrange filtration plant and rate for the same is included in this item. ii) DG set required for operation of filtration plant shall be arranged by the contractor and rate for the same is included in this item. iii) Any damage occurred to transformer during the process of dehydration shall be made good by the contractor to the entire satisfaction of the Engr-in-Charge at his own expenses. |
| 62 | Supply and pouring new transformer oil low viscosity EHV Grade as per IS : 335 (1993)for transformers installed at various site for topping up,complete all as specified and as directed by Engr-in-Charge.Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge. |
| 63 | M&L for disconnecting the HT & LT connections and taking down of existing Indoor/Outdoor transformer mounted on 2/4 pole structure/plinth/substation for of opening of top cover in situ or at wksp by unscrewing all nuts, bolts & wahsers draining out transformer oil upto required level and keeping in clean container for replacement of HT/LT bushings, for repair of tap changer gas kit, for lifting of core assy, for cleanning/repair and refixing complete with new cork sheet gasket, new nuts, bolts & washers for transformer, refilling of oil complete all as specified and as directed by Engr-in- Charge for transformer capacity 11/0.433 KV upto 500 KVA Note:(i)Quoted rate include arrangement of manpower, tools , plants , crane and recovery vehicle fortransportation and shifting of transformerto work shop and back if found defective. (ii) HT/LT bushings studsrequired new shall be measured separately under relevant item this BOQ as Supply only.(iii)Re-winding of defective winding of transformer, if required will be measured and paid separately under relevant item . (iv)Replacement of defective part shall be carried out only after inspection and recommendation of Engr-in-Charge (v)Any damage occurred to transformer during the process of disconnecting/taking down/transportation, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses. |
| 64 | Supply only HT porcelain bushing with packing for 11/0.433 KV Transformer complete all as specified and directed. |
| 65 | Supply only HT brassbush rod of suitable size for 11/0.433 KV Transformer complete all as specified and directed. |
| 66 | Supply only LV porcelain bushing with packing for 11/0.433 KV Transformer complete all as specified and directed. |
| 67 | Supply only LV brassbush rod of suitable size for 11/0.433 KV Transformer complete all as specified and directed. |
| 68 | Rewinding of HT/LT coils suitable for 11/0.433 KV grade with new super enamelled copper wire having class-F insulation as per existing size and design for any capacity and type of transformer. |
| 69 | Supply only Silica Gel for 11/0.433 KV Transformer complete all as specified and directed |
| 70 | Supply only Tap changer assembly complete for 11/0.433 KV transformer . |
| 71 | Sypply only Breather assembly made with polycarbonate base and clear aclylic glass of size min 50mm dia, min 120mm long for 11/0.433 KV transformerscomplete all as specified and as directed by Engr-in- Charge. |
| 72 | Supply only Transformer temperature gauge dial type having temp range 0 to minimum 120 degree celcius complete all as specified and directed |
| 73 | Material and Labour for preparing surfaces of transformer of capacity up to 630 KVA by rubbing old paint and applying two coats of spray painting with existing colur paintfrom outside and wiring SM/MES number after painting complete all as specified and as directed by Engr-in-Charge.Note.i)Painting of transformer will be carried out for plinth mounted and pole mounted transformer.ii)Necessary tools and plants shall be arranged by the contractor. iii)After completion of painting HT/LT outdoor bushing cable termination joint, oil inspection glass and name plates to be made clean using cleanner.iv) Contractor shall arrange electric supply for spray machine during painting. |
| 74 | Taking downHT11 KV VCB of capacity upto 800 Amps after disconnecting HT supply for servicing, repair, replacement of defective/worn out componenets and reassembling complete compreising of the following including testing and commissioning to the entire satisfication of Engr-in-Chage. Make of HT VCB -ABB/Crompton/Schnieder :- (a) Dismantling the HT Circuit Breaker from the enclosure consisting of vacuum interrupter assembly, socket contacts checking the serviceability of the partscarefully including cleaning, adjustments, replacement of defective/worn out parts and reassembling the units complete. (b)Cleaning the external surface of bushings with cleaner or liquid amonia to remove the accumulation of dirt or any other deposits, inspection of bushings and make sure that vibration due to breaker operation have not caused the busings to move resulting misalingment of contacts. (c)Checking the vaccum interrupter assembly and contacts, checking the alignment of contacts and setting the contact surfaces to bare firm and unitorm pressure and adjustment the gap as per manufacturers tolerance and replacement of badly spotted contacts. (d)Checking the breaker bushing of bus bar and circuit side inspecting the internal surface carefully for any charging/trackings, replacement of bushings etc. (e)Checking the condition of the spring charging motor along with gear box including servicing to motor commutator bushes lubrication of bearing surfaces etc. |
| 75 | (f)Checking the ratchet wheet assembly, driving and charging parts including replacement of defective ratchet wheet and parts. (g)Checking the operation mechansim of the breaker and ensure its operation freely through entire stroke.parts which shows excessive wear and tear to be replaced or adjusted as per manufacturers tolerance. (h)Review the adjustment of all pressure switches and lockout devices. (j)Inspecting all bolts nuts, pins and coller pin are in place and they are open/close properly. Note :- (i)Parts required shall be replaced under relevant items. (ii)Measurement of resistance value tools, labour, petrolium jelly are incl in the quoted rate of the item. |
| 76 | Supply only following material for HT 11 KV VCB of cap upto 800 Amps of make ABB/Kirloskar/Schnieder complete:- |
| 77 | Spout for 11 KV HT VCB |
| 78 | Housing of pole assebmly for 11 KV VCB of Make kirloskar/schnider/ABB |
| 79 | Pole assembly (vacuum bottle assembly/vacuum interrupter assembly for 11 KV VCB of make Crompton/schinieder/ABB |
| 80 | Shunt closing coil 24 V/110 V for 11 KV HT VCB |
| 81 | Shunt tripping coil 24 V /110 V for 11 KV HT VCB |
| 82 | Spring charge motor 220-250 V AC/DC suitable for 11 KV HT VCB |
| 83 | PT bushing of capacity 11 KV suitable to fit on existing PTs in 11 KV VCB |
| 84 | PT fuse of capacity 11 KV suitable to fit on existing PTs in 11 KV VCB |
| 85 | Power Pack with input voltage 230 V and output 30 V 5 Amps suitable with all connected wiring for backup of relay any type/any size |
| 86 | M&L for disconnecting and taking out numerical/micorporcessed relay any type or make (1 No UV/OV+1 No earth fault/over current + 1 No master trip relay) overhauling/repairing, testing, calibrating the relay by conducting primary and secondary injection test, checking with CT, rectification of defect in control wiring for proper tripping of circuit brakers through CTs, relays and tripping coil, adjustment/settingplug and time multiplier settings of the relay to achieve the discrimination in tripping time of upstream brakers, re-installation of the relay in circuit complete all as specified and directed. Note :-i) Standby electric supply required during calibration of relay shall be arranged by the contractor in quoted rate of item.ii) Rates for necessary testing kit, testing equipments, tools etc are included in the unit quoted rate adn detail test report shall be submitted to Engr-in-Charge without any extra cost. |
| 87 | Supply and fix in replacement of digital type 3 phase over current +earth fault relay with high setof capacity 24-240 Volt AC/DC complete all as specified and directed by Engr-in-charge. Make : L&T Model No. MC61AnX or its equivalent in C&S/ABB/Schneider |
| 88 | Supply and fix in replacement digital type multifunction meter VAF+ PF, 3 phase 4 wire AC 440 volts 50 Hz of rating 5 Amps with class 1.0 complete all as specified and directed. Make : L&T Model No. WL411020OOOO or its equivalent in C&S/ABB/Schneider |
| 89 | S&F in replacement 11 KV epoxy resin cast HT CT of ratio 50/5for protection, metering class 1.0 as per existing size/shape suitable for optimum performance of relay. |
| 90 | S&F in replacement 11KV/110V epoxy resin cast HT PT as per existing burden and existing size/shape suitable for optimum performance of relay. |
| 91 | M&L for preparation of steel surfaces of existing HT circuit breaker/SF6 braker/RMU unit including cleaning/scrapping of old painted surface, removing all the scrapped paint particals from the panel using the proper vacuum cleaner to the complete satisfication of Engr-in-charge applying two coats of synthetic anamel paint by using spray machine to finish the surface glosy of colour or shed approved incl marking of SM/MES number, incoming and outgoing, to and from etc complete all as specified and as directed by Engr-in- Charge. |
| 92 | S&F in replacement of capacitor, 3 phase, Heavy Duty cylinderical boxtypeself standing units of modular construction with sheet metal enclosure, for use on 415V to 525V, 3 phase, 50 Hz, of following Capacity, ACconfirming to IEC 60831-1 2/96, IS 13340 with MPP film heavy edge of capacitor complete all as specified and as directed by Engr-in- Charge. |
| 93 | 5 KVAR. |
| 94 | 10 KVAR. |
| 95 | 15 KVAR. |
| 96 | 20 KVAR. |
| 97 | 25 KVAR. |
| 98 | S&F in replacement contactor for capacitor3 phase with auxilary switch block 1NO+2NC, 440 volts suitable forcapacitor complete in various APFC panels complete all as specified and as directed by Engr-in- Charge. |
| 99 | 10 KVAR capacitor |
| 100 | 15 KVAR capacitor |
| 101 | 20 KVAR capacitor |
| 102 | 25 KVAR capacitor |
| 103 | S&F in replacement ON delay timer 12-120 sec forvarious APFC panels complete all as specified and as directed by Engr-in- Charge.Make L&T Cat No ST80329OOOO or its equivalent in Schneider/ABB. |