| 1 | Part A (Materials Provided by contractor) |
| 2 | Main Busbar complete with Structure |
| 3 | P.G. clamp for Dog conductor. |
| 4 | 33 KV. Top channel forneutral earthing |
| 5 | 33 KV Cable stand with cable clamp |
| 6 | 11 KV C/J Kit 3X185 mm² XLPE Indoor |
| 7 | 11 KV C/J Kit 3X185 mm² XLPE Outdoor |
| 8 | 11 KV C/J Kit 3X300 mm² XLPE Indoor |
| 9 | 11 KV C/J Kit 3X300 mm² XLPE Outdoor |
| 10 | Armoured copper control cable 2 x 2.5 mm2 |
| 11 | Armoured copper control cable 4 x 2.5 mm2 |
| 12 | Providing 6” dia.MS G.I. pipe 3m long with fitting |
| 13 | 11 KV DP Material |
| 14 | 11 KV Top Channel |
| 15 | 11KV Bracing angle |
| 16 | clamp with nut bolt |
| 17 | Extra support angle for cable support |
| 18 | Extra support angle clamp |
| 19 | PG Clamp for Weasel |
| 20 | Number Plate with clamps. |
| 21 | Danger Board with Clamps. |
| 22 | Barbed wire |
| 23 | Alluminium Paint |
| 24 | Red Oxide Paint |
| 25 | Bolts, Nuts, & Washers |
| 26 | PART - B- WORKShifting & loading of following materials on private truck at store centre Padrauna& carriage up to 33/11 KV Sub-Station Chhitauni Distt-Kushinagar & Un-loading of the same with proper stacking (Distance about0 to 40km ) |
| 27 | 11 KV ‘XLPE’ power cable. |
| 28 | 11 KV Incoming Pannel |
| 29 | 33KV ‘VCB’ complete with all structure. |
| 30 | 33KV. C.T. |
| 31 | Structure for above |
| 32 | 33KV Line Isolator |
| 33 | 33KV Bus Type Isolator |
| 34 | Structure for above |
| 35 | 33KV Double T/F control Pannel |
| 36 | 33KV lightening arrester |
| 37 | Structure for above |
| 38 | 33KV Post insulator |
| 39 | Structure for above |
| 40 | 11KV Switchgear panels(O/G) |
| 41 | ACSR Dog conductor |
| 42 | 33 KV Fuse set |
| 43 | Structure for above |
| 44 | 90 Ib, Rail pieces (44.64 Kg/M) |
| 45 | 33KV PT |
| 46 | 33KV PT Structure |
| 47 | ST Pole 11 M long |
| 48 | 33 KV. Polymer Disc Insulator B&S |
| 49 | 33 KV Disc Fitting for Dog. |
| 50 | 11 KV Disc Insulator T&C Type |
| 51 | 11 KV Disc Fitting |
| 52 | Stay complete |
| 53 | Earthing |
| 54 | Construction of power transformer plinth for 5 MVA transformer of size 3.5 x 3.5 x 0.5 mtr/as per site requirement hight will be increase or decreased. including cost of all material as per drawing. |
| 55 | 5MVA power transformer body earthing at two places including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials required. |
| 56 | Jointing charges of 11KV “XLPE” C/J kit 3 x 300/185 mm2 indoor/Outdoor type |
| 57 | Neutral earthing of 5MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials. |
| 58 | Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 5 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc. |
| 59 | Erection & Groutingfor cable stand and welding of M.S. flatat equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers. |
| 60 | GI PipeEarthing Complete forCable jointing Kit with materials |
| 61 | Erection,Installation of VCB(02 Nos.) andInstallation of 33 KV control panel for “VCB” with complete earthing with installation of battery and battery charger in control room and making connection.(complete wiring and istallation) |
| 62 | Laying of 11KV “XLPE” power cable 3x300 mm2/185 mm2 including digging of pits of xize 1.0x1.0 mtr. covering of cable with sand and 1st class brick around the cable. (AS per site requirement cable laying through trench if available and filling sand) |
| 63 | Labour charges for laying of 11KV 3x300sqmm/3x185sqmm XLPE Cable in loop after digging pit, Laying(In Loop) will be done with the help of first class bricks & Sand. |
| 64 | Labour charges for inserting of MS G.I. Pipe, Rising of 33/11KV cable and jumperingcomplete work. |
| 65 | Shifting of 11 KV switchgear to control room and placing in control room with grouting of bolts and mounting of switchgear panels properly. |
| 66 | Installation of Bus Coupler with complete earthingcomplete work. |
| 67 | Electrical connection of 11 KV switchgear panel and fitting of Bus Bar . |
| 68 | Testing of 11 KV switchgear panel in all respect. |
| 69 | laying ofcontrol cablefrom switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying. (AS per site requirement cable laying through trench if available and filling sand) |
| 70 | Size 2 x 2.5 mm2 |
| 71 | Size 4 x 2.5 mm2 |
| 72 | Earthing of indoor equipments |
| 73 | Erection and groutingof following structure. |
| 74 | 33 KV Bus Isolator structure |
| 75 | 33 KV fuse set structure |
| 76 | 33 KV Post insulator structure |
| 77 | 33 KV L.A. structure |
| 78 | 33 KV CT structure |
| 79 | 33 KV PT structure |
| 80 | Installationof following Equipments on erected structure and related connection |
| 81 | 33 KV Bus Isolator |
| 82 | 33 KV Line Isolator |
| 83 | 33 KV fuse set |
| 84 | 33 KV Post insulator |
| 85 | 33 KV L.A. |
| 86 | 33 KV CT |
| 87 | 33 KV PT |
| 88 | Earhing of outdoor type switchyard earthing for newly erected structure as per proper specification with GI Earthing strip, for all newly erected structures. |
| 89 | Jumpring from 33 KV Bus bar to post insulator, bus isolator, VCB, CT and LA to 5 MVA transformer etc.( Providing alluminium Lug and PG Clamp) |
| 90 | Painting of newly erected structure in switchyard (Applying on coat of good quality red oxide primer then two coat of good quality of high class luxol aluminium paint) |
| 91 | Erection & grouting of ST pole 11 m for making D/P to rising of cable with complete work and related fitting provided by contractor. |
| 92 | Providing and installation of Earthmat complete. |
| 93 | Charges for dismantling of old,used & damage structures & other materials and Carriage of old,used & damage structures & other scrap materials from 33/11KV SS-Chhitaunito store centre-Padrauna. |
| 94 | Charges For Erection of terminal Gantry,Making Bus-Bar & All Related complete work including cable supporting Structures/Stand |