| 1 | Supply, Install/errection, commissioning and testing of solar hot water heating system, includind stainless steelhot water tanksuitable capacity with insulation,flat plate collector type based on indirect transfer ofheat exchanger 2000 ltr per day capacity with electrical heating back up system complete accessories as per site requirement complete all as specified directed by Engr -in-Charge. and the following accessories as per site requirementfor fully satifaction upto Engr-in-charge. Make:- V-Guard/Kamal solar /Suprmesolar/SolarSack or as approved. |
| 2 | M&L forRotational moulded polyethylene water storagetank (cylindrical vertical with closed top) hoisted and fixed in position all as specified and dircted three layerwhite/black of capacity for 2000 ltr for solar water heater for raw water tank withnecessary plumbing work as per site requirement complete accessories.-01 Nos Make:- Sintex/Plasto/Rotex/Polywell or as approved. |
| 3 | Material and labour for galvanised iron chanels,angles,I-beamps (GI) cross arms, bracings, supports, GI clamps andincluding GI nuts, bolts, washers and necessary fabrications,cutting, welding, bending colt or hot, drilling holes for nuts,bolts, in any shape or size as indicated or directed and inclusive of red oxide primer two coats and two coat of aluminuim anti corrosive paintcomplete work upto fully satisfaction by Engr-in-Charge complete all asspecified and directed. |
| 4 | Material and labour for 3-layer PP-RPolypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.ISI Marked IS-15801 lying in trenches/wallc/ceilings or in floors and necessary clamps, saddles etc complete of size outer dia 32 to 40 mm complete all as specified and directed. |
| 5 | Supply and fixing PPR gate valve(Brass insert) of dia 40 mm fixing at near to building on wall upto one meter height complete all as spfd and directed. |
| 6 | Making connections of PPR pipes distribution branches with PPR main of following sizes of 50 to75mm by providing and fixing tee including cutting and making fusion joint etc |
| 7 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all asspecified and directed. |
| 8 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 9 | Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |
| 10 | Supply and laying/fixing alongwith wall Hot water pipe duly insulated with glass wool and aluminium cladding of dia 25 mm dia and including all necessories complete all as specified and directed. |
| 11 | M&L for old size brick work with fly ash bricks straight or curved on plan exc6m mean radius in CM 1:6 complete all as specified and directed. |
| 12 | M&L forrendering 15mm thick on fair face of brick works in CM 1:6 finished evenandsmooth with out using extracement complete all as specified and directed. |
| 13 | M&L for preparation of new plastered surface of walls or concrete and applying two coats of oil bounded distemper over a coat of primer complete all as specified and directed |
| 14 | M&L for preparation of old decorated surface of wall and apply two coats of white washcomplete all as specified and directed |
| 15 | M&L for applying two coats of oil bound distember on wall or concrete over a coat of primer on prepared surfaces including,rubbing with sand paper after complete removal of existing treatment complete |
| 16 | Supply and fixing PVC sheathed4 sqmm,3 core copper conductor heavy duty including providingPVC conduit 25 mm dia heavy duty type including necessary shaddling/clamping from main supply to Solar hot water back up system connector including providing on/off arrangements by suitable MCB SPN,240Volts,\"C\" series, 40-63 Amps,50Hz and necessary enclosure/DB as per site requiremet complete all as specified and directed.Make:- Havells/Polycab/Finolex |
| 17 | Supply and fixing 25 mm dia brass heavy duty type tap incl all necessary fixing arrangement/plumbig works suitable for hot water pipe for fixing complete all as specified and directed. |
| 18 | Material and labour for PCC 1:2:4 type B1 using (20 mm graded stone aggregate) for makingfoundation/base plinth and pole coping, foundation etc including necessary use and waste of form work complete all as specified and directed. |
| 19 | Supply and commissioning,testing complete chemical dehumidifier 600 CMH capacity,microprocessor based controling syatem having LED display,humidistat with digital display,CNC fabricated unit with pre-coated sheet,Eco-Dry rotor and tatally self-contained,non flamable,differential air pressure switch,high temparature thermostat cutout,cooling thermostat,electrical interlockingof fan motor,heaters and rotor drive as saefty measures,PTFT bonded silicon bulb seal,continuous operating, complete with heaters, necessary factory fabricated ducting, elctricall operated,3 phase,415 Volts ,50 Hz,8 KW,max current 11-12 Amps including electrical connections for 600 CFM,Air flow(M3/Hrs) Process-600,React -200 complete all as specified and directed.Make- Bry-Air Dehumidifier model FFB-600(600 CMH) or equivalent any approved make. |
| 20 | Supply, install, testing and commissinoningfloor mounted LT panel board outdoor type of size 800 mm long X 600 mm width X 300mm thickness(depth) suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, dust and vermin proof,made out of 3.0 mm thickat outer sheet and 2.0 mm thickat internal compartments CRCA sheet and duly powder coated, hinged doors with rubber gasket, handles.Panel shall have frontopening double door,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment and necessary marking with letter stickering, indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar/connectors fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating copper wire with RYB color code sleeves/taps and providing necessary studs,bolts,nuts & washersas per site requirement complete all as specified and directed and including comprising of following:- Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified. (ii)The contractor shall be arranged general (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(i)MCCB 160 Amps,4 pole, 25KA, 415 Volts thermal magnetic based-01 Nosincl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells(ii)MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-04 Nosincl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells(iii) MCB TPN 63 A,440Volts,50Hz,10KA \"C\" series-02 Make:-ABB/ Siemens/Schneider/Havells(iv) MCB SPN 32-40 A,240Volts,50Hz,10KA \"C\" series-02 Make:-ABB/ Siemens/Schneider/Havells(v)R,Y,B Phase indicating lamp -01 Set Make:- Jigo/L&T(vi)Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.Make:-AE/Selec(vii)Ammeter Selector switch -01 No.Make:-AE/Kaycee(viii) 200/5A current transformer -03 No\"s Make:-Kappa(ix)Digital Voltmeter( 0Voltsto 500Volts)-01 No with ASS, Make:-AE/Kaycee(x) Volmeter selector switch -01 No with VSS Make:-AE /Kaycee(xi)Protection fuses& controll wiringwith suitable rating/size-04 Nos Make:-Nippon |
| 21 | Supply and fixing servo controlled oil cooled voltage stabilizer for automatic operation, three phase naturally oil cooled,indoor type & designed for input variation between 240 Volts to 480 Volts with output voltage stabilized at 415 volts with accuracy +/- 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA.Make:-ITE Gurgaon,sinetrac,vintek,vinitec or as approved make. |
| 22 | Supply, laying & testing PVC/XLPE insulated armoured, heavy dutyelectric cable with stranded aluminium conductor,1100 volts of cross sectional area 16 sqmm,4 core including testing complete all asspecified and directed.Make:-Havells/polycab/Anchor |
| 23 | Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron strip of size 32 X 6 mmfrom earth electrodeto test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value completeall as specified and directed. |
| 24 | Supply and providingriver sand for cushioningwith dry cleansand 15 cm below cable and 8 cm above theunder ground cables and necessary fillings in thetrenches and punning to provide required cover complete all as specified and directed. |
| 25 | Supply andlayingbricks burnt claybricks sub class \"B\" for cable of size 250 x 115 x 75mm for protection under ground cable complete all as specified and directed |
| 26 | Supply and fixingsheet steelenclosure in CRCA sheet and incl providing MCCB100Amps ,4pole,415Volts,16/18KA MCCB and including providing necessary nut,bolts and washers and fixed in wall concealed/surface as site conditon complete all as specified and directed.make:-Havell/Legrand/Indoasian/ABB |
| 27 | Taking down old unsv/burnt LT panels/Feede pillar of any capacity and supply, install, testing and commissinoning ofLT panel board indoor type approximate sizesuitable to accommodated incoming and outgoing LT switch gears as mentioned belowas required and decided by Engr-in-charge) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 2 mm thickat outer sheet and 1.6 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6 mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings &Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(i)Incoming:- (a) MCCB,4 pole,415 Volts,50Hz Manual drawout type with microprocessor release of capacity 400 to 500 Amps,35/36 KA,extended rotary handle, suitable rating factory made spider links,steel nuts,bolts and washers& complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b)Control Instruments RYB indication lamps 240 V with control fuses with base -03 Nos Make:- L&T/Siemens/ABB/ Schneider or equivalent as approved make( c)Digital Volt & Ammeter 3 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,15VA,tape wounded with control wiring and safety fuses,MCBs etccomplete all as speficied and directed-03 NosMake:- L&T/Siemens/ABB/ Schneider or equivalent as approved make.(e) Necessary copper wire,1100volts of size 1.5 to 16 sqmm single core, heavy duty type of suitable ratings as per load for each control switch for incoming and outgoing controles. Make:- RR Kabel/Polycab/Finolex or equivalent as approved make(ii)Outgoing:- (a) MCCB 125 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory made spreader links & steel nuts,bolts and washers of suitable apms rating - 01Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) 20 HP Soft Starter feeder X 01 No with suitable MCCBs3/4 pole, rating, MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nos Make:- as approved by engr-in-charge/GE.(c) 10 HP Soft Starter feeder X 04 Noalongwith suitable MCCBs3/4 pole,rating , MPCB, 3 pole,TMA release for OL &SC 11A to 16 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,11-16A ,7.5KW,Pluging relay,240Volts,AC,2C/O with base -16 Nos,RYB indication lamps 240Volts,AC-04 Set with flush head push button (Red-04Nos,Green-04 Nos,Black-04 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-04 Nos,Single phase preventer protection & Safety-04 Nos,Mushroom Head Emergency stop push button-04 No,230V,AC-04 No, Digital Volt & Ammeter 1 Ph,Cl-1 (04 No) with suitable current rating CTs,CL-1,5VA,30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-04 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-04 Nos Make:- as approved by engr-in-charge/GE.(d) 5 HP Soft Starter feeder X 02 No alongwith suitable MCCBs3/4 pole,rating, MPCB,3 pole,TMA release for OL &SC 6.3A to 16A Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,9 to 10A ,4KW,Pluging relay,240Volts,AC,2C/O with base -8 Nos,RYB indication lamps 240Volts,AC-02 Set with flush head push button (Red-02Nos,Green-02 Nos,Black-02 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-02 Nos,Mushroom Head Emergency stop push button-02 No,230V,AC-02 No, Digital Volt & Ammeter 1 Ph,Cl-1 (02 No) with suitable current rating CTs,CL-1,5VA,30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-02 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-02 Nos Make:- as approved by engr-in-charge/GE. |
| 28 | Taking down old unsv/burnt LT panels/Feede pillar of any capacity and supply, install, testing and commissinoning ofLT panel board outdoor type approximate sizesuitable to accommodated incoming and outgoing LT switch gears as mentioned belowas required and decided by Engr-in-charge) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle andshall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, with see through glass as per requirement made out of 3 mm thickat outer sheet and 1.6 mm thickat internal compartments CRCA sheet andnecessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should beconnected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6 mm GI angle iron base frame ofheight 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4)type B1 with studs,bolts,nuts & washersas per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured should be followed by CPRI norms/certified.(ii)The contractor shall be arrangedGeneral (SLD), circuitlay out drawings & Switch gear items makes submitted for prior approval by theAccepting Officer/Engineer -in-chargebefore procurement/ordering.(i)Incoming:- (a) MCCB,4 pole,415 Volts,35/36 KA,50Hz Manual drawout type with microprocessor release of capacity 400 Amps,extended rotary handle, suitable rating spider links,steel nuts,bolts and washers& complete all as speficied and directed.-01 Nos Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) On-Load Change Over switch 400 Amps,4 pole,415 Volts,50Hzof capacity ,extended rotary handle, suitable rating spider links,steel nuts,bolts and washers& complete all as speficied and directed.-01 NosMake:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(c)Control Instruments RYB indication lamps 240 V with control fuses with base -03 Nos Make:- L&T/Siemens/ABB/ Schneider or equivalent as approved make(d ) Digital Volt & Ammeter 3 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,15VA,tape wounded with control wiring and safety fuses,Necessary busbar(RYB&N)complete all as speficied and directed-03 Nos Make:- L&T/Siemens/ABB/ Schneider or equivalent as approved make(e) Necessary copper wire,1100volts of size 1.5 to 10 sqmm, heavy duty type of suitable ratings as per load for each control switch for incoming and outgoing controles. Make:- RR Kabel/Polycab/Finolex or equivalent as approved make(ii)Outgoing:- (a) MCCB 40-100 Amps,3 pole, 25KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating for existing eqpts - 12 Nos. Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved .(b) 40 HP Soft Starter feeder X 03 No with MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-03 Nos Make:- as approved by engr-in-charge/GE.( c) 20HP Soft Starter feeder X 03 No with MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-03 Nos Make:- as approved by engr-in-charge/GE.(d) 7.5 to 10 HPSoft Starter feeder X 03 No with MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-03 Nos Make:- as approved by engr-in-charge/GE.(e) 3 to 5.0HP Soft Starter feeder X 03 No with MPCB,3 pole,TMA release for OL &SC 24A to 32 Aps with exteded rotary handle,Auxiliray contact block for MPCB with base with soft starter,30A ,15KW,Pluging relay,240Volts,AC,2C/O with base -04 Nos,RYB indication lamps 240Volts,AC-01 Set with flush head push button (Red-01Nos,Green-1 Nos,Black-01 Nos),Local-Remote selector switch,2Pole,2Way,6Amps with off-01 Nos,Mushroom Head Emergency stop push button-01 No,Exhaust fan with louver,230V,AC-01 No, Digital Volt & Ammeter 1 Ph,Cl-1 (01 No) with suitable current rating CTs,CL-1,5VA30/5A,tape wounded with control wiring and safety fuses all as speficied and directed-01 Nos,MCB,DP/SPN,10KA,C-Series,6A for control supply-03 Nos Make:- as approved by engr-in-charge/GE.(iii)(a) MCCB 125 Amps,4 pole, 25KA, 50Hz,415 Volts with microprocessor based release and inclproviding steelcoatedfactory fabricated spreader links & steel uts,bolts and washers of suitable apms rating - 01 Nos - Make:-ABB/ Siemens/Schneider/Legrand/Havells or equivalent as approved . |
| 29 | Taking out old unsv existing on load change over with wall mouted sheet steel enclosure any type/rating and incl providing supply and fix on load change over switch 415V in wall mounted sheet metal enclosure/open excution type/side handle type as per site requiremet 4 pole of capacity 400 amps and including providing incoming and outgoing cables features and necessary hole fasters, lugs,nuts,bolts and washers etc and including providing necessary alterations,welding works in existingpanels/on wall mounting fitting complete all as specified and directed.Make- Havells/Standard/Legrand as approved by GE |
| 30 | M& L for in repair earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn inconduit pipe or fixed to poles or any other indicated situation for loop earthing etc as requiredgalvanised ironsteel earth strip of size 25x4 mm sizefor earthing connectivity conductor incl providing suitable heavy duty insulators,nuts,bolts and screws etc with insulators for three number in each running metre complete all as specified and directed. |
| 31 | Cutting of bituminous top road,PCC surface/floor by using mechanical method incl road boaring/cuttingany type carefully without damagig to surrounding area complete all as spfd and directed. |
| 32 | Material and labour for PCC 1:2:4 type B1 using 20 mm grade aggregate as in pre castcover slabs including form work and set in cement motor 1:6 complete all as spfd and directed. |
| 33 | Supply and fixing galvanised steel cable tray of size 250mm X100 mmx 5 mm tray fixing on wall with proper nuts,bolts ,GI clamps and washers etc fixing at ay height on wall surface and necessary anchoring arrangements,cuttings,jointings,weldigs,fabrication as per site reqt suitablefor UG cable laying complete all as specified and directed. |
| 34 | Material & labour for GI pipe 80 mm \" light grade\"\" laid in trenches floors/on,pole/road for cable protection with all fittings complete all as specified and directed.Make:-Jindal/Tata/Swastik/BST. |
| 35 | Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed. |
| 36 | Material & labour for GI pipe 50 mm \"light grade\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.Make:- Jindal/Tata/swastik/BST |
| 37 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 16 sqmm,3.5 core complete all as specified and directed.Make:- Havells/Polycab/Finolex or as approved |
| 38 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 25 sqmm,3.5 core complete all as specified and directed.Make:- Havells/Polycab/Finolex or as approved |
| 39 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 35 sqmm,3.5 core complete all as specified and directed.Make:- Havells/Polycab/Finolex or as approved |
| 40 | Supply and fixing in repairs modular switch 1 way,16Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement andincluding removing old usnv items complete all as specified and directed. |