Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-03-2025 |
| 2 | 11-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-03-2025 |
| Sl. No. | Item Description |
| 1 | Checking, servicing, preventive maintenance, cleaning (Dry and Wet), inspection and testing of window/Split type Air condineer of capacity 1.5/2 Ton of inverter/ non invertor type or any model and make at site in Multi story buildings as per OEM guideline for safety and performance by means chekcing operation performance parameters, cleaning of blower, condenser fan, cleaning or replacing the air filters, cleaning the condeser and evaporator coils, checkiing the refrigerant level and testing for leakage and topping off refrigerant level, inspecting and tightening electrical connections, lubricating moving parts, checking thermostate calibration, checking the PCB controller cards and capacitor * Remote control handset in and including anti corrosive coating blue/gold fin on condenser and evaporator coils complete all as specified and as directed. |
| 2 | All as per item Ser No 1.00 above but split type/cassette type AC/Inverter type AC 1.5/2.0/3.0/4.1 TonNote: For Item 1&2, the quoted rate shall deemed to be in clusive of the following aspect : -(a) Two team (2 Techanician and 2 helper and complaint lodged by user should be rectified within 24 Hrs if more then two team required in summer season it will be responsibility of contractor to provide) of AC mechanic of having minimum 3 year experience any authorized service centre of LG/ Voltas/ Daikin/ Carrier/ Hitachi/ Blue Star/ Carrier/ Panasonic. Technician & Helper will be present daily in MES complaint cell M\"House separately from 0930hrs to 1730hrs Monday to Friday, if mechanic & helper is absent from duty or not reported on duty the responsibility lies on contractor and a sum of Rs 2000/- per day of absence shall be deducted from the contractor dues on account of absence.(b) Cost of filters, refrigerant of any type anti corrosion nitrile insulation Blue/Gold fin coating, lubricants and any other consumable items required for routine maintenance and servicing as inticated under sr item No. 1 to 2 above to keep the AC in perfect serviceable condition and rate quoted shall be deemed to be included in the quoted rate of the contractor.(c)The cost of T&P including scaffolding/ rope suspended mobile platform/ suspended / cradle/ hydra/ crane etc and safety equipments of works is deemed to be including in quoted rate under respective items being work at multi storey buildings. |
| 3 | S&F in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacityof approved Make and required Size to suit existing AC complete all as specified and directed. |
| 4 | All as per Item Ser No. 3.00 above but AC(Window/Split Type). 2.0/3.0 TR Capacity |
| 5 | M&L in replacement rewinding Fan Motor of AC 1.5 TR/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper winding Wire of appropriate Gauge and Quantity including insulating materials complete all as specified anddirected. |
| 6 | S&F in replacement Air circular BlowerFan Motor ofAC (Split Type), 1.5 TR/2.0 TR./3.00TR Capacity complete all as specified and directed. |
| 7 | S&F in replacement Air Filter suitable for AC (Window type) 1.5 TR/2.0 TR Capacitycomplete all as specified and directed. |
| 8 | S&F in replacement Air Filtersuitable for AC (Split type)1.5 TR to 3.0 TR Capacity complete all as specified and directed. |
| 9 | S&F in replacement CapacitorRunning 36 mfd – 56 mfd suitable for new/star rated AC (Window/Split Type)1.5 TR/2.0 TR/ 3.0 TR Capacity and of any make complete all as specified and directed. |
| 10 | S&F in replacement capacitor 80 mfd – 120 mfd suitable for old ones AC(Window/Split Type)1.5 TR/2.0 TR Capacity and of any make complete all as specified anddirected. |
| 11 | S&F in replacement Fan Blades for AC (Window/Split type)1.5/2.0 TR capacitycomplete all as specified and directed. |
| 12 | S&F in replacement Fan MotorCapacitor 4 mfd suitable for new/star ratedAC (Window/Split Type) 1.5 TR/2.0 TR capacitycomplete all as specified anddirected. |
| 13 | S&F in replacement Fan MotorCapacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.50/2.0/3.0 TRcapacity complete all as specified and directed. |
| 14 | S&F in replacement Front Plastic Grill (as per Sample) of AC (Window type)1.5 TR/2.0 TR Capacity complete all as specified anddirected. |
| 15 | S&F in replacement Front Plastic Grillfor inner unit (asper Sample) of AC (Splittype)1.5 TR/2.0 TR Capacity complete all as specified anddirected. |
| 16 | S&F in replacement runner for Air blower motor of AC (Split type) 1.5 TR/2.0TR capacity complete all as specified and directed. |
| 17 | S&F in replacement Single Pole Contactor 25A Capacity, MR 11W type suitable for AC (Split Type) complete all as specified and directed. |
| 18 | S&F in replacement Starting Relay of AC(Window/Split Type) 1.5/2.0/3.00 TR Capacity complete all as specified anddirected. |
| 19 | S&F in replacement Strainer with Capillary Tube of AC(Window/ Split Type) 1.5/2.0/3.0 TR Capacity complete all as specified anddirected. |
| 20 | M&L in replacement Thermostat Switch of AC(Window/Split Type) 1.5 /2.0/3.0 TR Capacity complete all as specified and directed. |
| 21 | S&F in replacement cooling coil suitable forwindow type room AC 1.5/2 ton capacity complete all as specified and directed. |
| 22 | S&F in replacement Condensing coil suitable forwindow type AC 1.5/2 ton capacity complete all as specified and directed. |
| 23 | S&F in replacement Condensing coil suitable for split type AC 1.5/2.0 Ton capacity complete all as specified and directed. |
| 24 | S&F in replacement cooling coil suitable for split type AC1.5/2.0 Ton capacity complete all as specified and directed. |
| 25 | S&F Indoor unit suitable for 1.5 TR split type ACcomplete all as specified and directed. |
| 26 | S&F outdoor unit suitable for 1.5 TR splittype AC without compressor complete all as specified and directed. |
| 27 | S&F Indoor unit suitable for2 TR split type AC complete all as specified and directed. |
| 28 | S&F outdoor unit suitable2 TR splittype AC, without compressor complete all as specified and directed. Note for Item Srl NO 25 to 28 :- Old unserviceable Indoor/Outdoor unit shall be deposited to MES store yard. |
| 29 | Supply & Fixing in replacement hermetically sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed. |
| 30 | All as per ser item No. 29.00 above but for split/ window type AC capacity 2.0 Ton. |
| 31 | All as per ser item No. 29.00 above but for split type AC capacity 3.0 Ton three phase run. |
| 32 | Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 includingre-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed. Note:- Compressor shall be procured from authorised dealer and contractor shall submit purchase vouchers alongwith written guarantee/warantee as per manufacturer. |
| 33 | All as per Item No. 32.00 above but AC 2.0/3.0 TR Capacity (Window/Split Type). |
| 34 | M&L in replacement invertor PCB with remote and sensor for windowtype AC upto 2 Ton capacityincluding cells of remote complete all as specified and directed . |
| 35 | M&Lfor repair of invertor PCBof windowtype AC upto 2 Ton capacity complete all as specified and directed . |
| 36 | M&L in replacementinvertor PCBwith remote including sensorfor Split type AC 2.0 to 3.0 Ton capacityincluding remote cells complete all as specified and directed. |
| 37 | M&L for repair invertor PCB of Split type AC 2.0 to 3.0 Ton capacity complete all as specified and directed. |
| 38 | M&L in replacement PCB & motherboard with remotecomplete setforInverter Split type AC up to 2 Ton capacityincluding remote cell complete all as specified and directed. |
| 39 | M&L in repairPCB & motherboardcomplete setforInverter Split type AC up to 2 Ton capacity complete all as specified and directed . |
| 40 | M&L in replacement Remoteof AC ( Window/Split Type) 1.5/2.0 TR capacity(As per sample or as per site requirement) including remote cell, complete all as specified and directed. |
| 41 | S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete all as specified and directed. |
| 42 | M&L in replacement gas charging pin valve complete all as specified and directed. |
| 43 | Taking out window type AC complete unit from any height/ any floor up to sixstorey buildingand shifting to another locationin the sameor other building in the complex including refixing & reconnection of the unit, testingcomplete all as specified and directed. |
| 44 | Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to sixstorey buildingbyincluding pumping down the gas into thecompressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiionin the sameor other building in the complex including refixing of the unit with electric connections and testing complete all as specified and directed. |
| 45 | Supply and charging the refrigerant gas R22 in window type AC upto 2 ton capacity after and including testing with application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogengas complete all as specified and directed. |
| 46 | All as per ser item No. 45 above but R- 410/32 for split type AC up to 2 TR capacity. |
| 47 | S&F in replacement Hermatically Sealed compressor upto 360 Ltrs capacity Deep freezer/refrigerator including brazing the sunction and discharge lines complete all specified and directed.Note:- Compressor shall procured compressore from authorised dealer and contractor shall submit purchase vouchers alongwith written guarantee/warantee as per manufacturer. |
| 48 | S&F in replacement of casing of window type AC including company fitted condensing & cooling coil suitable for 1.5 TR capacity complete including PCB except compressor complete all as specified and directed. |
| 49 | M&L in replacement split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed. |
| 50 | All as per ser item No. 49.00 above but of Size 1/2\". |
| 51 | S&F in replacement compressor shut off valve 3/8\" for split AC up to 2.00 ton capacity complete all as specified and directed. |
| 52 | S&F in replacement compressor shut off valve 5/8\" for split ACup to 2.00 toncapacity complete all as specified and directed. |
| 53 | S & F in replacement of electrolyte grade copper tubing of size 1/4\" dia,having thickness 0.9mm suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. |
| 54 | Allas per item Ser No. 53.00 above but size 1/2\" dia, having thickness 1.25mm |
| 55 | All as per item Ser No. 53.00 above but size 3/8\" dia, having thickness 1.25mm |
| 56 | All as per item Ser No. 53.00 above but size 5/8\" dia, having thickness 1.25mm |
| 57 | S&F in replacement High density polyethylene pipes 20 mm dia (HDPE) of pressure rating 6 kgf/cm2, laid in wall/ceilingincluding all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 6 (six) storey complete all as specified and directed. |
| 58 | All as per item No. 57 above but size 40mm dia |
| 59 | S&F in replacement synthetic rubber foamfor insulation for refrigerant copper piping of existing size 1/4\" to 5/8\" internal dia, split type AC complete all as specified and directed.Note for 53 to 59 :- The cost of T&P including scaffolding/ rope suspended mobile platform/ suspended scaffold/cradle/hydra/ crane etc and safety equipment of works is deemed to be including in quoted rate under respective items being work at multi storey buildings. |
| 60 | S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including brazing the suction and discharge lines complete all specified and dircted.Note:- Compressor shall procured compressore from authorised dealer and submit purchase vouchers alongwith written guarantee/warantee as per manufacturer. |
| 61 | All as per item No 60.00 above but compressor for water cooler upto 150 Ltr capacity |
| 62 | S&F in replacement metal plug top Single pole & Neutral and earth, 20 Amps, 240 volts suitalbe for sheet metal enclosures complete all as specified and directed. |
| 63 | S&F in repalcement sheet metal enclosure with clad socket & plug top, Single pole and neutral enclosure with a two pin and earth plug and socket including MCB SP, 25 Amps, 240 voltscomplete all as specified and directed. |
| 64 | S&F in repalcement sheet metal enclosure with clad socket & plug top, Triple pole and earth, encolsure with a three pin and earth plug with socket with one triple pole MCB complete including MCB TP 63 Amps 240 voltscomplete all as specified and directed. |
| 65 | S&F in replacement PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm cable complete all as specified and directed. |
| 66 | S&F in replacement PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm cable complete all all as specified and directed. |
| 67 | M&L in replacement submain wiring including PVC conduit 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded FRLS cable drawn through PVC conduit25mm dia medium duty with all accessories including 4.0 Sqmm multi stranded copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly complete all as specified and directed. Note:- 3 RM of4 Sqmm cable & 01 RM of PVC conduit shall be measured as one unit (RM). |
| 68 | S&F MS work as in replacement of AC stand suitable for out door AC unit (split/cassette type), capacity of 2.0/3.0 TR made out of mild steel angle iron 40x40x6mm,including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete allas specified and as directed Note :- (i) Dismension and design of stand shall be as approved.(ii) Steel surfaces shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including preperation of surfaces and quoted rate shall deemed to be included for this provision. |
| 69 | S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC complete allas specified and as directed. |
| 70 | Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstall -ing, Testing, connecting the same after replace-ment of defective/burnt Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed.Note:- Compressor shall be procured from authorised dealer only & contractor shall submit purchase vouchers alongwith written guarantee/warantee as per manufacturer |
| 71 | All as per item No. 70.00 above but capacity 120/150 Ltrs |
| 72 | M&L for servicing of water coolerof any capacity (40 Ltrs to 150 Ltrs) including cleaning of water cooler from inside and outside with potassium permaganates, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed. |
| 73 | Supply and charging the gas in the water cooler of any make and capacity up to 150 ltrs capacity including testing and detecting leakage if any with nitrogen gas and vaccum the system after rectification of all leakages complete all as specifiedand directed. |
| 74 | S&F in replacement thermostat switch suitable for water cooler of any make & size complete all as specified and directed. |
| 75 | S&F in replacement starting relay/over load relay suitable for water cooler of any make & size complete all as specified and directed. |
| 76 | S&F in replacement push cock, 15 mm bore cast copper alloy, chromium plated, heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. |
| 77 | M&L for preparation of old painted surfacesof water cooler of upto capacity 150 Ltrs by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint by spray painting complete all as specified and directed. |
| 78 | S&F in replacement fan motor suitalbe for water cooler as per existing make and capacity upto 150 ltrs complete all as specified and directed. |
| 79 | S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed. |
| 80 | S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed. |
| 81 | S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 82 | S&F in replacement steel waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed. |
| 83 | M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, i.e. fan kit, motor, water pump and connected accessories complete all as specified and directed.Note : Unserviceable parts required for replacement shall be measured and paid separately as \"supply only\" under respective items of this schedule. |
| 84 | M&L for painting ofdesert cooler capacity upto 4000 Cfm with one coat of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directedNote : The rates are inclusive of taking down coolerfrom any height, removal to workshop for painiting and refixing in position after painting including connection and testing. |
| 85 | Supply only desert cooler sub mersiblewater pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed. |
| 86 | supply only for desert cooler fan motor,copper wound suitable for upto 450mm sweep including metal fan blades SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed. |
| 87 | S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed |
| 88 | S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed. |
| 89 | S&F in replacement of plug top 3 pin 15 Amps complete all as specified and directed |
| 90 | S&F in replacement of motor capacitor 2.5/3.15/4 mfd complete all as specified and directed. |
| 91 | S&F in replacement of front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed. |
| 92 | S&F in replacement of desert cooler body, capacity upto 4000 cfm without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare & accessories complete all as specified & directed |
| 93 | S&F in replacement of float valve assembly with PTMTferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specifiedand directed |
| 94 | S&F in replacement wood wool pad,(Khus Khas) set of threecovered by GI wire mesh suitable for desert cooler complete all as specifed & directed |
| 95 | S&F in replacement desert coolers complete with side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body including suitable size fan, submersible pump etc complete set suitable of capacity 4000 Cfmall spare & accessories complete all as specified and directed.Note :- Old unserviceable desert coolers will be deposited with MES store yard and taken over in charge by the deptt. |
| 96 | Taking down Ceiling fans/exhaust fans/Wall fans, Ceiling cable end, dismantling blades and removing fan and blades & deposited to E/M store yard and refixing the same at site after necessary repair workcomplete all as specified and directed. |
| 97 | M & L for overhauling of ceiling fan/pedestal/exhaust/table/air circulating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same location, connection & testing complete all as specified and directed. |
| 98 | M & L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified & directed. |
| 99 | All as per item srl No 98.00 above but for exhaust fans of size 300 mm sweep to 380 mm sweep |
| 100 | All as per item srl No 98.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep. |
| 101 | All as per srl item No 98.00 above but for table fan/wall mounted fan of 450 mm sweep Note for item srl No 98 to 101 :-(i)Defective fans shall be collected from MES stores and deposit the same after necessary repair work.(ii)Painting & replacement of defective ball bearings and rubber seal shall be measured and paid separately under relevant items. |
| 102 | M&L in replacement ball bearing for ceilng/table/pedestal/ Air-circulators fan of size 6201/6202 complete all as specified & directed |
| 103 | All as per srl item No 102.00 above but for exhaust fan of size 6203/6204 . |
| 104 | M&L in replacement rubber real of suitable size for ceiling fan complete all as specified and directed |
| 105 | M&L in replacement gun metal bush suitable for any type/model/size of fans complete all as specified and directed |
| 106 | S&F in replacement fan step regulator, modular type, 120W, 2 Module complete all as specified and directed |
| 107 | M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by sprayingafterfilling cavities with filler and preparation of surface including marking complete all as specified and directed |
| 108 | All as per item No 107.00 above but exhaust fan/wall fans/Pedestral fans of size 300 mmto 450 mm sweep. |
| 109 | S&F in replacement of voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase complete all as specified and directed. |
| 110 | S&F in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity 2 TR working on AC 240 V, 50Hz, single phase complete all as specified and directed. |
| 111 | S&F in replacement wall mounted fan high speed 450mm sweep working on AC 240 V, 50Hz, single phase copper winding complete all as specified and directed. Note :- Old/unserviceable fan shall be deposited in MES store yard and taken over by the deptt. |
| 112 | S&F in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase copper winding complete all as specified and directed.Note :- Old/unserviceable fan shall be deposited in MES store yard and taken over by the deptt. |
| 113 | S&F in replacement exhaust fan, steel body, AC single Phase, 230V of size 300mm sweep with, blades, frame and GI louvers in copper winding complete all as specified anddirected. Note :- Old/unserviceable fan shall be deposited in MES store yard and taken over by the deptt. |
| 114 | S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed. Note :- Old/unserviceable fan shall be deposited in MES store yard and taken over by the deptt. |
| 115 | Supply and fixing in replacment ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 5.00 BEE. Five star rated copper winding complete all as specified and directed.Note :- Old/unserviceable fan shall be deposited in MES store yard and taken over by the deptt. |
| 116 | All as per item 115.00 above but 1400 mm sweep, min air delivery 245 CFM. |
| 117 | S&F in replacement down rod suitable for 1200/1400 sweep ceiling fan complete all as specified and directed. . |
| 118 | Taking down of geyser of capacity 25 ltrs after disconnecting the water and electric connections etc complete all as directed and S&F stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position including connection & testing complete all as specified and directed. |
| 119 | All as per ser item No. 118.00 above but capacity 50 ltrs. |
| 120 | S&F in replacement Heating element triangle/round type as per existing, capacity 1.5KW of Hot appliances complete all as specified and directed. . |
| 121 | All as per ser item No. 120.00 above but capacity 2KW. |
| 122 | S&F in replacement thermostateas per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. |
| 123 | Supply and fixing in replacement Oil Room Heater, 2900 Watt, Suitable for 11 Fin,weight 18 Kgwith fan complete all as specified and directed. |
| 124 | Supply and fixing in replacement indicator light (Red & Green) as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. |
| 125 | S&F in replacement shut off valve as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . |
| 126 | S&F in replacement Thermo insulation glass wool as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . |
| 127 | S&F in replacement water connection CPfor inlet & outlet (Hot & Cold) as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . |
| 128 | S&F in replacement Heater suitable for double door refrigerator/deep freezer, capacity 360 Ltrs complete all as specified and directed. |
| 129 | S&F in replacement PVC distributors, PVC elbow & PVC Pipe best quality 15mm dia for desert cooler of capacity 4000 CFM complete all as specifed and directed. |
| 130 | S&F in replacement angle valve, 15 mm dia, cast copper alloy, screwed down, high pressure,with crutch handle, fancy type, chromium plated and fixed complete all as specifed and directed. |
| 131 | Supply and fixing in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, connecting & testting complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specifed and directed.Note :- Old/unserviceable gyser shall be deposited in MES store yard and taken over by the deptt. |
| 132 | All as per item srl No 131.00 above but 50 ltrs capacity. |
| 133 | M&L for proctective/Anti epoxy coating after chemical wash the VRF OUTDOOR unit to remove carbon, rust and to minimise the Air conditioners gas leak problems from pipes/brazing joints, cooling coils, or all unprotected copper pipes from weather/environmental effect/prolonged corroded condition and also to improve their life span and further protect from corrosion by applying single step coat of Automotive solution or copper preventive coat or any other equivalent solution ISI marked and approved by OEM by spray coating machine in all outer door unit of VRV system13x14 HP and 13x12 HP and their connected indoor units all types under a skilled/qualified supervisor\"s supervision complete all as specified and directed. |
| 134 | Comprehensive annual maintenance of Daikin VRV system indoor units and outdoor units (338HP).NOTE FOR ITEM NO 134 :-(i) Out door units (Make: DAIKIN) of capacity mentioned below:-(a) Total number of outdoor unit- 26 No and total capacity of outdoor units- 338HP. (13X14HP+13X12HP).(ii) Indoor units (Make:DAIKIN) of capacity mentioned below:-(Total 54 units) (a) Cassette 3 TR : 07 Nos (b) Ductable 8.50TR : 5 Nos.(c) 6.0 TR Ductable : 38 Nos(d )Split AC 1.5 TR : 4 Nos. (iii) Remote controls |
| 135 | (i) The following Part/components are covered under the scope of comprehensive maintenance of VRF/VRV type AC system are as under: -VRF/VRV outdoor and indoor units covered under the following item.OUTDOOR: Control PCB Card, Inverter PCB Card, Fan PCB card, Noise PCB Card Power Control PCB Card, 4 way valve, expansion valve, NRV, Solonide Coil Compressor 12/14HP, Fan Motor Mechanical Valve, Air Sensor, Hugta pressure/loty pressure sensor, capillary tube oil separater condenser, coil Power Transistor, Divert ModuleINDOOR:Main PCB, Power PCB, Fan Motor, Blower, Drain Pump, Display PCB, Corded remote, Display PCB, Copper Piping, Insulation, Control wiring. Evaporator Coil.(ii) Repair and replacement of above mentioned item other than (BOQ/Sch-A) required for making fully functional is deemed to be included in quoted rate no extra cost shall be paid to contractor in this effect. Hence the bidder is advise to visit the site to assess the quantum of work to be carried out in this contract and quote their rate accordingly. |
| 136 | Comprehensive annual maintenance of VRF system indoor units and outdoor units and (2x18HP)& (2x16HP) at SAG.NOTE FOR ITEM NO 135 :-(i) Out door units (Make:Hitachi)of capacity mentioned below:-(a) Total number of outdoor unit-06 No andtotal capacity of outdoor units -100HP.(16x4+18x2)(ii) Indoor units (Make:Hitachi) of capacity mentioned below:-(Total 47 Units)-(a) Ductable 1.60 TR: 31 Nos. (b) Ductable 2.00 TR: 12 Nos.(c) Ductable 2.60 TR : 04 Nos(iii) Remote controlsNote:- cost of out door/Indoor unit above mendioned when required to repair and replacement of all type PCB cardcompressor Gas charging , sensor other than mentioned in BOQ making the fully functioned is deemed to be included in quoted rate no extra cost shall be paid to contractor in this effect. Hence the bidder is advised to visit the site to assess the quantum of work to be carried out in this Contract and quote in their rate accordingly. |
| 137 | The following Part/components are covered under the scope of comprehensive maintenance of VRF/VRV type AC system are as under: -VRF/VRV outdoor and indoor units covered under the following item.OUTDOOR: Control PCB Card, InverterPCB Card, Fan PCB card, Noise PCB Card, Power Control PCB Card, 4 way valve, expansion valve, NRV, Solonide Coil, Compressor 16/18HP, Fan Motor, Mechanical Valve, Air Sensor, High pressure/low pressure sensor, capillary tube, oil separator, Aqumlater, Condenser Coil, Power Transistor, Divort Module.INDOOR: Main PCB, Power PCB, Fan Motor, Blower, Drain Pump, Display PCB, Corded remote, Display PCB, Copper Piping, Insulation, Control Evaporator Coil. wiring.(ii) Repair and replacement of above mentioned item other than (BOQ/Sch-A) required for making fully functional is deemed to be included in quoted rate no extra cost shall be paid to contractor in this effect Hence the bidder is advise to visit the site to assess the quantum of work to be camed out in this contract and quote theirrate accordingly. |
| 138 | Comprehensive annual maintenance of Package type indoor units and outdoor units (4x5.5TR), AHU including Servicing-02 times washing of air fiter monthly at DESIDOC. complete all as specified and directedNote: (i) The following Part/components are covered under the scope of comprehensive maintenance of Package type AC system are as under: -Package type units covered under the following item.OUTDOOR: Control PCB Card, Inverter, PCB Card, Fan PCB card, Noise PCB Card, Power Control PCB Card, 4 way valve, expansion valve, NRV, Solonide Coil, Compressor 4x5.5TR, Fan Motor, Mechanical Valve, Air Sensor, High pressure/low pressure sensor, capillary tube, oil separator, Aqumlater, Condenser Coil, Power Transistor, Divort Module.AHU: Main PCB, Power PCB, Fan Motor, Blower, Drain Pump, Display PCB, Corded remote, Display PCB, Copper Piping, Insulation, Control wiring, Evaporator Coil.(ii) When repair and replacement of above mentioned item other than (BOQ/Sch-A) are required for making fully functionally is deemed to be included in quoted rate no extra cost shall be paid to contractor in this effect. Hence the bidder is advise to visit the site to assess the quantum of work to be carried out in this contract and quote their rate accordingly.Add a Note below Item Sr No. 136 Note for Item Sr No. 134 to 136(i) Everyday one technician has to be deployed for day to day maint and rectification of faults if any and failing which Rs 1000 will be charged as penaltyper day. Technician should report its attendance to Engr-in-charge. |
| 139 | M&L For replacement of air filter for AHU of 19200 CFM, Make Zeco including Taking down complete all as specified and directed.Note for 134 to 137 :- (i) Everyday one technician has to be deployed for day today maint and rectification of faults if any and failing which Rs 1000 will be charged as penalty for every day. Technician shouldreport its attendence to Enge-in-charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail