| 1 | Cleaning of septic tankofany capacity by mechnical means including vaccume suction,taking off suitable capacity fitted with vaccume sunction pump of capacity not less than 15 cum/hr and deposited the sludge and water outside the MOD landcomplete all as specified and directed. |
| 2 | M&L for cleaning of sewage line SWG/CI pipe/ RCC pipe/PVC pipe etc vertically/horizontally of dia n.exc 200mm by rodding and well flushing by using sufficient water and making itclear for easy flow of sewage from WC, gully trap, Nahani trap etc upto the first manhole including desludging of first manhole and making it the proper functional to entire satisfaction of Engineer-in-Charge and removing the sludge, silt away from Bldgs etc upto a distance exc 50 m and n.exc 500 m and burying it in pits and covered with earth complete all as specified and directed. |
| 3 | All as per Srl item No 02 here -in-before but length of sewage line cleaned manhole to manhole complete by rodding and well flushing with sufficient water, length of sewage line upto 10 M including desludging of both sides existing manholes complete all as specified and directed. |
| 4 | All as per Srl item No 02 here -in-before but length of sewage line cleaned exc 10 M but n.exc 25 M from manhole to manhole including desludging of both sides existing manholes complete all as specified and directed. |
| 5 | Cleaning of blockage of gully traps, Nahani traps, Floor traps incl removing gratings and re-fixing old or new gratings with white cement complete all as specified and directed. |
| 6 | Dewatering of soak well of any dia and depth completely by pumping out the water and removing it to nearby nala where directed complete all as specified and directed. |
| 7 | Cleaning of man holes of any size and depth by any means and getting out sludge and water and removing to a distance upto 100 mtr and burried into pits covered with 20cm thick soil complete all as specified and directed. |
| 8 | Taking down old unservicable SWR pipe of any dia including fittings complete all as specified and directed |
| 9 | S&F 110 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clampscomplete all as specified and directed. |
| 10 | All as per Srlitem No 09 here -in-before but laid in trenches or in floors complete all as specified and directed |
| 11 | S&F in PVC (SWR) bends 110 mm dia complete all as specified and directed. |
| 12 | S&Fin repairs PVC (SWR) bendsof bore 110mm with acess door complete all as specified and directed. |
| 13 | S&F in repairPVC (SWR) junction single ( single T ) equal or unequal 110mmdia complete all as specified and directed. |
| 14 | S&F in repair PVC (SWR) 110 mm diajunction, with acess door single(single \"T\")equal or unequal complete all as specified and directed . |
| 15 | S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 16 | S&F 75 mm dia PVC(SWR) pipes single soketed in any length with adhesive jointed fixed to wall with mild steel clampscomplete all as specified and directed. |
| 17 | All as per Srlitem No 16 here -in-before but laid in trenches or in floors complete all as specified and directed.. |
| 18 | S&FPVC (SWR) bends 75mm dia complete all as specified and directed. |
| 19 | S&F in repair PVC (SWR) bends 75mm dia with acess doorcomplete all as specified and directed. |
| 20 | S&F in repair for 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant cement including PCC 1:2:4 and making good the existing floor complete all as specified and directed. |
| 21 | Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed. |
| 22 | M&L for brickwork with subclass \"B\" old size bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:4 using bricksof crushing strength not less then 35 Kg/cm2complete all as specified and directed. |
| 23 | M&L forbrick work with sub class \"B\" brick (old size), in cement mortar 1:4, straight or curved on plan to any radius in half brick thick wall complete all as specified & directed. |
| 24 | M&L Brick work with subclass \"B\" bricks in one brick thick honey comb walling built in CM 1:4 complete all as per specified and directed. |
| 25 | M&L Brick batsusingsubclass \"B\" bricks for loose filling in soak wells etccomplete all as per specified and directed. |
| 26 | M&L cutting into existing manholes for (dia 150mm / 200mm) connecting new or old drains making good to pipes and rendering,cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required all as specified and directed |
| 27 | Demolition of RCC of roof, beams, landing, chajja, cover slabsand similarsuspended work complete all as specified and directed. |
| 28 | M&L forRCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in slabs supported on walls as in soak well and septic tank etc complete all as specified and directed. |
| 29 | M&Lfor form work to soffits of suspended slabs such as flator curved roof slabs, floor slabsn exc 200mm thick finished fair or curved concrete surface complete all as specified and directed.. |
| 30 | M&Lfor form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 10cm wide and sides of RCC / PCC bandsin walls, horizontal or slopping and similar worksfair finished concrete surface complete allas specified and directed.. |
| 31 | M&L for mild steel TMT bars10mmdia and overcut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming toGde Fe complete all as specified and directed. |
| 32 | M&L for mild steel TMT bars6 to 8 mmdia cut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Gde Fe complete all as specified and directed. |
| 33 | M&L for mild steel round bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending as in manhole covers handles, steps, rungs etc complete all as specified and directed. |
| 34 | M&L for pre-cast Reinforced Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab of mane hole set in cement mortar 1:4 including demolition of existing broken cover slabs complete all as specified. |
| 35 | Demolition of cement concrete of any description andin any position complete all as specified and directed. |
| 36 | M&L for cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregates) as in foundations, filling ,bedding under pipe and mass concrete complete all as specified and directed. |
| 37 | Excavation in trenches n exc 1.5 m widen exc 1.5 m deep in soft/ loose soil for foundation etcor for shaft, wells, manholes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed. |
| 38 | Ditto all as per item No.39 above but exc 1.50 M depth not exc 3.00m depth all as specified and directed by Engr in charge |
| 39 | Removing excavated soil n exc 0.50m depositing where directed at alevel n exc 1.5 metre above the starting pointcomplete all as specified and directed. |
| 40 | Returning ,filling in including spreading ,levelling watering and well ramming withsoil in layers n exc 25 cm thick complete all as specified and directed. |
| 41 | Demolition and breaking up drain pipes (salt glazed ware)/ RCC/HDPE pipeof 150mm bore dia pipe set in cement mortar,including bedding,haunching pcc etc, complete all as specified and directed. |
| 42 | Demolition and breaking up drain pipes (salt glazed ware)/ RCC/HDPE pipeof 200mm bore dia pipe set in cement mortar,including bedding,haunching pcc etc, complete all as specified and directed. |
| 43 | Demolition and breaking up drain pipes (salt glazed ware)/ RCC/HDPE pipeof 300mm bore dia pipe set in cement mortar,including bedding,haunching pcc etc, complete all as specified and directed. |
| 44 | S&F HDPE double wall corrugated sewage pipe of 150 mm internal bore SN-8 as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer instruction complete all asspecifed and directed. |
| 45 | S&F HDPE double wall corrugated sewage pipe of 200 mm internal bore SN-8 as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer instruction complete all asspecifed and directed. |
| 46 | S&F HDPE double wall corrugated sewage pipe of 300 mm internal bore SN-8 as per IS 16098 Part-II 2013 laid in trenches, jointed and tested as per manufacturer instruction complete all asspecifed and directed. |
| 47 | M & L for RCC. pipes 150 mm bore,Class NP2 laid, jointed and tested complete with collars including demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etcset in cement mortar of 150 mm bore pipe complete all as specified and directed |
| 48 | All as per Srl item No. 47 here -in-before but abovebut 200 mm bore pipes including demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etcset in cement mortar of 200 mm bore pipecomplete all as specified & directed |
| 49 | All as per Srl item No. 47 here -in-before but abovebut 300 mm bore pipes including demolition and breaking up drain pipes (salt glazed ware)/ RCC pipe etcset in cement mortar of 300 mm bore pipecomplete all as specified & directed. |
| 50 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 (using 40mm graged stone aggregtaes) for 150mm mm dia pipe work in foul position complete all as specified & directed. |
| 51 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 (using 40mm graged stone aggregtaes) for 200mm mm dia pipe work in foul position complete all as specified & directed. |
| 52 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8, type D2 (using 40mm graged stone aggregtaes) for 300mm dia pipe work in foul position complete all as specified & directed. |
| 53 | S&F in repairs vitreous China urinal bowl, flat back of size 465mm x 355mm x 265mm (minimum) whitewith grating and union for discharge pipe , waste pipe(excluding flushing cistern,flush pipe ) complete all as per specified and directed. |
| 54 | S&F in repairsvitteous ChinawareEWC padestal type closet with whiteseat & cover with flat bottom with hinging device etc. complete all as per specified and directed. |
| 55 | S&F in repairsvitreous China squatting pan \"Orrisa pattern\" size 580mm x 440mmwhitewith integral foot rests any pattern including provn of cement concrete bedding and making connection with & including P or STrap, etccomplete all as specified and directed. |
| 56 | S&F in repairs PVC low level flushing cisternof 10 Ltr capacity including flushing pipe bend PVC bendcomplete all as specified and directed. |
| 57 | S&F in repair bib taps, cast copper alloychromium plated fency type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed. |
| 58 | S&F in repair angular/stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup screwed both ends for iron pipe or for unions 15 mm bore, complete all as specified and directed by Engineer in charge.. |
| 59 | S&F in repair Hand shower (Health faucet) Cast copper alloy chromium plated with 8mm dia , one metre long flexible tube & wall hook complete screwed for iron pipe bore dia 15mm complete all as specified and directed. Make :Jaquaror equvalent |
| 60 | S&F as in repair Multi bib tap 2 in 1 , cast copper alloy chromium platedfency type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm boreand fixed complete all as specified and directed. |
| 61 | S&F PVC connections 15mm bore size450mm in length with both endbrass/pvc high quality nuts complete all as specified. |
| 62 | S&F in repairs Toilet paper holder with flap chromium plated brass complete all as specified and directed. |
| 63 | M&L forcoloured anti skid ceremic tiles 7 to 8 mm thickarea of each tiles exc. 0.06 sqm and n. exc. 0.11 sqm (300 x 300 mm joint free (rectified) )as in floor set &jointed in neat cement slurry and pointed in white /coloured cement to match the colour of tiles laid over and including15 mm thick screed bed in CM 1:6 including dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 64 | M&L for glazed ceramic tiles of size450 x 300 x 7mm thick,(joint free (rectified))coloured, on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white/ coloured cement to match laid over and including 15 mm thick rendering in CM 1:4 including dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 65 | M&L 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in levelling course of sub base finished even and rough to receive the topping layer, including demolition of floor,complete all as specified and directed. |
| 66 | Treatement for sunken portion is as follows :-(i)Demolition of lean concrete and other/any type & condition of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed.(ii)M&L for water proofing plaster for sunken portionin CM 1:3, 20 mm thick in two coats with water proofing compound at the rate of 2% by weight of cement and finishing the surface even and smooth without using extra cement.(iii) M&L for applying two coats of Dr fixit compound suitable for sunkun treatment as per manufacturer instructions over vertical surfaces and floors of sunken of toilet including cleaning of surfaces.(iv)M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in filling (sunken portion). etc.(v)M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, mixed with WPC @ 2% by wt. of cement, as sub base, 75mm thick on top. |
| 67 | Taking down cement plaster on brick or stone walls, ceiling , chajjaetc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 68 | M&L for rendering 15mm thickcement plaster in cement mortar 1:4 onbrick work / Concrete surfaces finishing the surfaces even and smoothwith out using extra cement complete all as specified and directed. |
| 69 | M & L for applying three coats of white wash on new plastered wall/ceiling/chajja surface including preparation of surfacec omplete all as specified & directed. |