| 1 | Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kinds of soil |
| 2 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 3 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 4 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, strap beam, raft , bases of columns etc. upto plinth leval |
| 5 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 7 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 8 | Painting with Aluminium paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 9 | Providing and fixing of reinforced ferro-cement drain cover. designed for class \"A\" loading duly marked on cover with adequate steel reinforce- ment having thickness 75mm to 150 mm, anti-corrosive bitumen painted M.S. plate, rim and on M.S. lifting hooks, admixture like plastisizer bond-improving compound, shrinkage resistant compound, abrasion resistant complete as per approved design etc. 1500 x 600 mm (150 mm thick) |
| 10 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.3 core 300.0 Sq.mm |
| 11 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 33 KV End Termination Kit Outdoor type3 core 240/300/400 Sq.mm |
| 12 | Providing, installing & commissioning of Fast Bus Transfer System (FBTS) 2000 PANEL, Complete in all respect including Transportation at site, insurance , GST etc. as per manufacturer\"s specifications. |
| 13 | Bus Transfer System (BTS) 2000 Panel1. Includes design, Engineering, Approval, Manufacturing, Inspection & delivery at site.2. Its 3 breaker(2 I/C & 1 B/C) BTS 2000 (bus transfer scheme) |
| 14 | Cable supplyArmoured control 1100 volt LT cables(halles/Polycab/Eq.) for BTS panels to switchgear (Breaker, PTs etc.) Length 40 meters for each BTS panel. |
| 15 | Service Work(BTS panel eraction, installation, cable laying, tagging, glanding, lugging-ferruling, termination at BTS panels-switchgear end, testing, commissioning, Noload-load trials, software simulation, training at site max 10 days for each panel) |
| 16 | Laptoplatest laptop(Dell/HP/Eq) with BTS 2000 software, (Relay tool & BSCOPE), 4 communication cables. |