| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc., |
| 2 | Demolition of cement concrete (reinforced) Concrete of any description and in any position not otherwise specifically provided. |
| 3 | M&L OF Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to removedust, etc & Brushing neat cement slurry with 3.0kg of cement per sq. metre. |
| 4 | S&F of 2.00 mm thickness PVC tiles/ sheets,laminated plain coloured, marbled mosaic or mottled finish, laid with ap-proved rubber basedadhesive in floors any undulation has to bee levelled using felling layer. |
| 5 | M &L for vitrified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and screed bed or bedding layer in CM1:3,20mm thick for laying floor finishes. |
| 6 | M&L for Excavating in post holes inhard/dense soils (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm. |
| 7 | Suppy and fixing of steel Fe 410 -W (GDE-E-250)QuiltyA- work in tubular trusses, square tube,rectungalar tube, hollow section including special shaped washer etc. complete using ERW or induction butt welded tubes on forming to I. S.1161- 1979 grade St.-240 . |
| 8 | M&L for sand filling under foundations,flooring,etc,including watering and consolidation. |
| 9 | M & L for P.C.C 1:4:8, D2 type using 40mm graded aggregated Cement concrete in foundations,filling and mass concrete. |
| 10 | M&L for cement concrete in foundation ,filling and massconcretetypeB2 1:2:4 using 20mm aggregate. |
| 11 | Supply & fixing of anodised aluminium frame for partition,doors, windows, ventilators with one or more rebates including joining cleat for fixing and powder coating (minimum thickness of powder coating 50 micron)etc. complete all as specified. |
| 12 | M&L for pre-laminated particle board of 12 mm thick with pre-laminated both sides with decorative choice lamination. |
| 13 | S & F of 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane. |
| 14 | S&F of Anodised aluminium snap grid 605 x 605 mm frame work for false ceiling all as specified. |
| 15 | M&L for Exposed metal frame ceiling with 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) |
| 16 | Material and labour for applying two coats of plastic emulsion on calcium silicate board / ceiling paint / new ceiling surfacesof any description over 10 cm girth or width, not other wise described,Including preparation of new surfaces |
| 17 | S & F of Aluminium anodised,Barrel tower bolts (150mm) of extruded section and fixed. |
| 18 | S & F of butt hinges (125mm) cast, brass with mild steel hinge pin,bright polished and fixed but type B-12 |
| 19 | S & F of Aluminium handles (150 mm), cast type,anodised |
| 20 | S & F of Aluminium die cast Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 21 | S & F of Mortice lock,vertical type, size 100 mm )with four levers, Brass body and fixed . |
| 22 | S & F of Floor door stopper ofbrass bodyOverall length of cover plate (140 mm)and tongue, anodised,with hard drawn steel spring,fixed in floor. |
| 23 | Material and labourfor painting steel surfaces of any description over 10cm width or grith with two coats of synthetic enamel paint over a coat of red oxide,zinc chrome primer including preparing new surfaces. |
| 24 | M&L for Plastering with 1:4,15mm thick onfaces of old brick work and concrete surfaces. |
| 25 | Material and labour for applying two coats of plastic emulsion paint with one coat primer on internal & exterior wall and old painted surfacesof any description over 10cm girth or width, not otherwise described all complete, including preparation of old surfaces |
| 26 | Removal of debris (rocks) exceeding 1.5Km but not exceeding 5 km and depositing where directed. |
| 27 | Removal of soils exceeding 1.5Km but not exceeding 5 km and depositing where directed. |
| 28 | Material and labour for Point wiring withPVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc.mount on a wall/roof etc. including same size copper earth continuity wire.a) one light point or one fan point controlled by one switch with cables1.5 sqmm size. |
| 29 | Material and labour for Point wiring withPVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc.mount on a wall/roof etc. including same size copper earth continuity wire.b) One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sqmm size. |
| 30 | Material and labour for Point wiring withPVC insulated sheathed single core cable 1100V grade confirming to IS 694 multi strand copper conductor along with 2mm thick PVC conduuit accessories run on wall or roof including M.S. switch box concealed in the wall(made out of 3mm thick sheet) and laminated sun mica sheet 3mm thick cover for housing the switches, regulators and plug socket etc.mount on a wall/roof etc. including same size copper earth continuity wire.c) One 3 pin socket outlet 5 amps on indepedent with cables 2.5 sqmm size. |
| 31 | Supply & Fixing of wiring for circuit/sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC conduita) 2x2.5 sqmm + 1x2.5 sqmm earth wire |
| 32 | Supply & Fixing of wiring for circuit/sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC conduit b) 2x4.0 sqmm + 1x4.0 sqmm earth wire |
| 33 | Material & Labour for connecting to the system modular type switches 6A single pole one way (Make:,LEGRAND MYRIUS/ Litaski/ Crabtree) or Suitably equivalent make |
| 34 | Supply, fixing and connecting to the system of socket, 6A-2/3 pin combined modular type 2 module (Make:LEGRAND MYRIUS/ Litaski/ Crabtree) or Suitably equivalent make |
| 35 | Supply & fixing of 6 module modular white cover plate with frame |
| 36 | Supply & fixing of metal flush box for 6 module plate |
| 37 | Supply & fixing of 8 module plate with frame |
| 38 | Supply and fixing of LED luminaire 600mmx600mm,40 watts,220v AC recessed typewith highefficiency PMMA diffuser soft glare free light complete eith driver, holders & LED lamp sutable for roofceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 39 | Takingdown old point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of wall, floors, etc. |
| 40 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning. (Make: LEGRAND / HAVELLS / ABB)orsuitably equivalent make |
| 41 | Supply and fixing TPN/FP 40 to 100 AMP 415V 10KA \"B\" curve miniature circuit breaker (MCB)poles and current carrying capacity in the DB complete with connection testing and commissioning. .(Make: LEGRAND / HAVELLS / ABB) orsuitably equivalent make |
| 42 | Supply and fixing of single pole and neutral enclosure with a two pins and earth plug and socket complete with one single pole MCB20 amps, 240V (Make: Standard/Havels/Siemens/Legrend) or suitably equivalent make |
| 43 | Supply, fixing & connecting to the system of Sheet metal enclosures with double door DB\"s when MCB\"S to be used Triple pole & neutral 4 way,415 V with 200 Amps rated busbar, (Make: Legrand/Havells / ABB)orsuitably equivalent make |
| 44 | Material & LabourforPVC/Polycorbonate, isolatedceiling rose 5A, 230V, AC , two to three terminals. Make: (ANCHOR/HAVELLS /KUNDAN) orsuitably equivalent make |
| 45 | Material & Labour for laying of 4 core 10 sq.mm 1100 voltage grade heavy duty, armoured, U.G. cable with XLPE insulated aluminum conductor. |
| 46 | Supply & fixing of galvanised steel tubes, medium grade 20mm dia for ceiling fan down rod. |
| 47 | Supply and fixing ofexhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers (Make: Almonard/ Khaitan/ Crompton) or Suitably equivalent make) |
| 48 | Supply fixing of sheet metel enclosre for DBs when MCB s to be used single pole & neutral ,4 way double door,200 amps rated busbar,. (Make: Legrand/Anchor/Havells) or suitably equivalent make. |
| 49 | Supply and fixing amp rating 240V 10KA \"C\" curveminiature circuit breaker (MCB) of SPN 32 AMPcurrent carrying capacity,in the MCBDB complete with connection testing and commissioning. |
| 50 | Supply & fixing 240 Volt,10KA \"C\" curve MCB of single pole 6 to 32Amps in the MCB DB complete with connection testing and commissioning. (Make: Legrand/Anchor/ Havells)or suitably equivalent make. |
| 51 | Demolition of cement concreteof any description and in any position(unreinforced) |
| 52 | Material and labour for cement concrete 1:2:4 Type B2 using 20mm graded aggregate in foundations, filling and mass concrete |
| 53 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), 3 Years onsite Warranty.IS 374-2019 (Make : Crompton - Energion Riviera/ Atomberg - Renesa Alpha/ Havells - Efficiencia Neo /orient - Hectre 500 / Luker - Eco 30 Neo / Luminous - Triana) or suitably equivalent make |
| 54 | Supply & fixing metal flush box for 8 module plate |
| 55 | Supply & fixing of 12 module plate with frame and metal flush box |
| 56 | Supply & fixing of modular type Dummy plate |
| 57 | Supply of 400mm sweep pedastal fan with supply card and plug top 230V,AC, (MAKE: BAJAJ/ ANCHOR/ CROMPTON/ ALMONARD/USHA/KHAITAN/ORIENT/HAVELLS/POLAR) or Suitably Equivalent make |