| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 4 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 5 | M&L for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed. |
| 6 | M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 7 | M&L for PCC (1:2:4),type- B1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs not provided , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and specified |
| 8 | M&L for RCC (nominal mix) Type B0 (1:2:4) (12.5mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, etc complete all as specified and as directed.(Note: Reinforcement shall be measured & paid separately) . |
| 9 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 10 | M&L for brick work with sub class \"B\" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 11 | Use and waste formwork to soffits of suspended slabs such as roof slab, floor slabs, landing covers, and similar works,for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm,complete all as specified and directed. |
| 12 | S&F 20 mm bore, brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and as directed. |
| 13 | S&F mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5cm long complete all as specified and as directed. |
| 14 | M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 15 | S&F Joist channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates etc,(cut to ordinary lengths i.e within 20mm of the length indicated) complete all as specified and directed. |
| 16 | S&F rolled mild steel in steel worktubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 2014 grade St.-240 complete all as specified and as directed. |
| 17 | S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 18 | S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed. |
| 19 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded aggregate) thick as in plinth protection/Hard standing , etc finishing cement concrete surface even & fair without using extra cementmaking joints with bitumastic filling in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 20 | M&L for non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying of floor finishes complete all as specified and directed. |
| 21 | M&L for 20mm thick granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and 10mm thick backing coat of cement mortar (1:4) complete all as specified and directed. |
| 22 | M&L for Kota stone slab 18-20mm thick in floor laid over and including 20 mm thick screed bed or bedding layer of cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. |
| 23 | M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooringcomplete all as specified and directed. |
| 24 | M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10mm thick each layer) in cement mortar in (1:4) using water proofing compound in top layer andfinished even and smooth without using extra cement complete all as specified and directed.Note:Water Proofing Compound will be measured and paid separately. |
| 25 | Supply only liquid Water Proofing Compound of approved make. |
| 26 | M&L for preparation of newly plastered surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 27 | M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 28 | S&F 15 mm bore medium grade galvanized steel water tubingwith all fittings, fixed to wall/ceiling or laid in floor complete all as specified. |
| 29 | S&F 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 30 | S&F chromium plated Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot\" or `Cold\" with long screwed shanks & fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 31 | S&F 15mm bore stop valves (concealed type) cast copper alloy fancy type chromium plated long sunk and cup screwed both ends foriron pipe or for unions and fixed complete allas specified and directed. |
| 32 | S&F 110 mm bore, PVC (SWR), Type \"B\",soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc completeall as specified and as directed. |
| 33 | S&F 110 mm bore, PVC (SWR) bends with access door of any radius complete all as specified and as directed. |
| 34 | S&F vitreous china wash basin of size 580x450mm, white, flat back, excluding taps, waste pipe, chain, plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. |
| 35 | S&F 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm - 210 gms)complete all as specified and as directed. |
| 36 | S&F brass chromium plated shower rose, 125 mm size with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and as directed. |
| 37 | S&F 600x450mm bevelled edge mirror of selected quality glass mounted on 6mm thick commercial plywood with aluminium framed allround fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed. |
| 38 | M&Lfor concealed point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core FRLSH PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers including cutting chases and making good by using cement mortar 1:4 complete for one light / fan point / call bell complete. |
| 39 | S&FSwitch piano, flush type, single pole, one way switch5 Amps ISI marked complete all as specified and as directed. |
| 40 | S&F Ceiling rose surface PVC, 3 terminals 65x50mm ISI marked complete all as specified and as directed. |
| 41 | S&F 35 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08 including all fixing arrangement complete all as specified and as directed. |
| 42 | S&F LEB batten (1.2M) made of extruded aluminum housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency or 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and as directed. |
| 43 | S&F MCB Distribution board SPN 4 Way for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed. |
| 44 | S&F miniature circuit breaker (MCB)SPN 6 to 32 Amps\"C\" Series 10 KA 240 volts complete all as specified and directed. |
| 45 | S&F miniature circuit breaker (MCB) SP, 240 Volts,6 to 32 Amps, \"C\" Series, 10KA capacity complete all as specified and directed. |
| 46 | S&F street light bracket arm of length not less than 1.5 m made out of GI tubing, 32mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed. |
| 47 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary excavation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed. |
| 48 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 10 Sqmm, 2.0 core stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items.(2) Excavation and earth work shall be measured and paid separately. |
| 49 | M&L for clear sand cushioningfor protection of cable complete all as specified and directed. (only punned down thickness to be measured) |
| 50 | Supply and laying un-reinforced precast concrete cable cover , class LV, type -1, flat of size 250x150x40mm, used for power cables upto and including 11 KV with minimum breaking load capacity upto 200kg as per IS: 5820:1970, complete all as specified and directed. |
| 51 | S&F 32 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 52 | Supply, laying, connection and testing, 32mm outer dia 3- layer PP-R polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and anti microbial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately. |
| 53 | S&F PP-R gate valves of size 32 mm outer dia (brass insert) connect to PP-R pipe complete all as specified and as directed. |
| 54 | M&L for making connection of PP-R distribution branch with PP-R main of size upto 40mm outer dia by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed. |
| 55 | Supply, Installation, testing and commissioning of 60W All-In-One LED Solar Streetlights made up of Aluminium Extrusion housing with minimum 150Wp Monocrystalline Panel fixed on the top side of luminaire housing (Battery, charge controller and LED module should be integrated inside Luminaire). Maintenance free 12.8V/60Ah LiFePo4 battery along with BMS (BIS certification required)with minimum cycle life of 2000 cycles, MPPT Charge controller with Efficiency > 90%. Luminaire should be IP65 & IK08 and have lumen output of greater than 10000 lumens at full power (System Efficacy > 170 Lumens/watt) as LM79 from third party NABL accredited Lab. The LED chip used should be of Osram, Lumileds, Cree, nischia only with CRI>70 and CCT – 5700K +/- 500K and should be with lenses for effective light distribution. Solar Panel, MPPT charge controller, and luminaires should of Same make and Light fixture along with MPPT controller should be manufactured in in-house manufacturing facility only. The solar lighting company must have inhouse NABL accredited lab with scopeas per ISO17025:2017 to include for testing Safety and Performance Standards for LED Lamps, LED Modules, LED Drivers, Luminaires and Photometry parameters as per LM79:2019 and IES TM30-18 standards . Luminaire must have Green & Red indicator lights for showing charging of battery and low battery voltage respectively. Light fixture must also have protections like Over-Charge protection, Deep-discharge protection,current protection , Short circuit protection , Over voltage protection. The light fixture should come with a PIR sensor for auto dimming of light fixture based on movement and Complete system should be designed to provide 2 days (24 hours) backup in dimming mode. The light fixture should also come with hybrid controller so that light fixture works on AC power if the battery goes down in case of adverse weather conditions. the solar light suitable for side mounting on existing pole and taking down existing street light. The solar lighting companies must have toll free base service network to provide immediate after sales service networks available in different districts of the state. Certificates to be submitted :- (a) LM79 (Third party NABL accredited Laboratory only).(b) LM80.(c) BIS certificate of Battery.(d) BIS certificate of Solar Panel.(e) IK08 and IP65 certificate (Third Party NABL accredited Lab only). |
| 56 | Fixing only LED street light fitting obtained from item No. 55 including nut and bolt with all accessories complete all as specified and directed. |
| 57 | S&F for mild steel Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\") complete all as specified and as directed. |