| 1 | Supply and fixing of 7mtr G.I.Octagonal pole of approved make (top dia 70mm,bottom dia 130mm & base plate 12mm thick) having 3mm thickness with single arm bracket length 1mtr. Length in 1:2:4 RCC Foundation both including the cost of foundation , excavation & back filling and required T&P complete in all respect. 21.2 CAT AAA |
| 2 | Supply and fixing of 7mtr G.I.Octagonal pole of approved make (top dia 70mm,bottom dia 130mm & base plate 12mm thick) having 3mm thickness with double arm bracket length 1mtr. Length in 1:2:4 RCC Foundation both including the cost of foundation , excavation & back filling and required T&P complete in all respect. 21.2.1 CAT AAA |
| 3 | S/F of LED StreetLight fitting with mandatory driver set having die cast Al Body with tuffened glass uv stablized pc cover and Lenses suitable for 110 to 130W and confirming to IP 66 and IK 07 and above protection having company logo engraved complete in all respect including labour 13200-15600 system lumens high power LED lenses,120 l/w, PF >095 ,THD <10%,CRI>70,potted driver set in metal housing(Not Circuitory) phase to phaseprotection at 440V and>300V auto cut and restart feature,4KV internal Surge Protectionwith 5 year warrenty. 23.17 CAT AAA |
| 4 | Supply and fixing of decorative 40W to 45W LED post top indirect light luminare having pressure die cast Al Body anduv stablized pc clear /frosted glass cover ,with driver set confirming to IP 66 & IK 08 protection,potted driver(not circuitory) complete in all respect . 4800-5400 system lumens high power LED lenses,120 l/w, PF >095 ,THD <10%,CRI>70, over votage protection >300V and auto restart feature,4KV internal Surge Protectionwith 5 year warrenty. 23.21 |
| 5 | Making Connection of each street light fitting by 1.5 sq mm 3 core flexible copper from pole busbar box to street light fitting. 1.7.1 |
| 6 | Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 20.1.9 |
| 7 | Supply and Making end termination with brass compression gland and aluminium lugs for 4x16sqmm (28mm) size of PVC insulated and PVC sheathed/XLPE AL conductor cable of 1.1 KV grade as required. 9.1.33 |
| 8 | S/F of SPMCB 6Arating,240/415V,10KA,\"C\" curve, miniature circuit breaker suitable for inductive loadfor controlling of street light including cost of din mounting rail,connecting strip,earth link etc complete in all respect. 2.10.1 |
| 9 | S/F of DPMCB 32 A rating,240/415V,10KA,\"C\" curve,miniature circuit breaker suitable for inductive load double pole in the existing MCB DB complete with connections,testing and commissioning etc.as required. 2.10.3 |
| 10 | S&F surface/flush mounting 6ways SPN distribution board with additional metal door without MCB complete in all respect, as directedbyEngineer in charge. 2.3.1 |
| 11 | S/Laying of 4\" (100mm) dia GI Pipe B-Class medium18.8.7 |
| 12 | S/F Angle iron Safety Cage for Decorative Post Top Quotation |
| 13 | S/F of 6 KW capacity of automatic light cubical control panel painted with anti corrosive alkali and acid proof paint consisting of digital 24 hour timer switch ,32A TP Contactor,40A TPN MCB FRLS Internal wiring,in built short circuit protection , Class H Protection.compelete in all respect.Analysis |
| 14 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra)Quotation |
| 15 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Quotation |
| 16 | Supply & Laying 25mm x5mm GI Strip at 0.5m below ground as strip earth electrode including connection /terminating with GI nut bolts, spring ,washer etc as required. 5.9 |
| 17 | SITC of 1200mm Sweep ,BEE 5star Rated ceiling fan with brushless direct current motor class of insulation B,3Nos Blades 30cm long down rod ,2Nos canopies,shackle kit ,safety rope ,copper winding ,PF not less than 0.9 ,service value minimum 6,air delivery minimum 210cum/min , 350RPM ,THD less than 10% ,insulation resistance more than 2mega ohm suitable for 230V 50Hz. single phase AC supply, earthing etc. complete as required. 19.1 |
| 18 | S/F Fresh Air Fan 300mm sweep(Mettalic) Quotation |
| 19 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Quotation |
| 20 | Supply and fixing of CO2 type fire extinguisher 4.5kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Quotation |
| 21 | S/E of factory fabricated &wired metal clad dust & vermine proof floor mounting M.S Channel base with bottom and top cable Electrical Control Panel with TPN MCCB Incoming100 A /415V MCCB-1 No.Outgoing 63Amp. MCCB-1No. 32Amp. MCCB-2No20.1.1 c(ii) |
| 22 | GST 18% |