| 1 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soils complete all as specified and directed. |
| 3 | Excavating over areas, depth exc 1.5 m and not exc 3.00beyond the first depth and getting out in soft/loose soils complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 5 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&L for Hardcore using broken stone or boulders of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 7 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 8 | M&L for 200 mm thick (compacted) in two layers of each 100mm thick inpavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6(ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 9 | M&L for loose filling of coarse aggregate (40 to 80 mm gauge broken stone or boulders) packed in suitable gunny bags as in filter bed at weep holes etc complete all as directed. |
| 10 | M&L for Sand filling under floors or in foundation or in filter bed at weep holes etc complete all as specified and directed. |
| 11 | M&L for cement concrete type (C-2) 1:3:6 using 40mm grded stone aggregate as in foundations, filling and mass concrete in post holes all as specified. |
| 12 | M&L for PCC type D2, 1:4:8 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | S&F Mild Steel TMT bars 10mm dia bar and over, cut to lenghth, bent to shape requird, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip all as directed by Engineer in Charge. |
| 14 | All as per item No 13.00 herein before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complte as directed. |
| 15 | M &L for RCC (Design mix) M-25type B1 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified. |
| 16 | M&L for Reinforced cement concrete M-25 (Design Mix) using 20mm graded aggregate as inSlabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deckslabs and in shelves and the like |
| 17 | M&L for Reinforced cement concrete M-25 (Design Mix) using 20mm graded aggregate as inColumns,pillars,piers,posts and struts. |
| 18 | M&L for reinforced cement concrete (Design Mix) M-25 Type B1 (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. |
| 19 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat fair finished surfaces of concrete complete all as specified and directed. |
| 20 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or slopingfor rough finished surfaces complete all as specified and directed. |
| 21 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough flat surfaces complete all as specified. |
| 22 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form for rough finished surface of concrete (flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed. |
| 23 | M&L for damp proof course 40mm thick M-20 (Nominal Mix) using 12.5mm graded stone aggregate with water proofing compound conforming to IS-2645 liquid grade as per manufacturer’s instructions with and including polythene film 200 micron over and including 85/25 grade Industrial bitumen (IS-702 : 1988) @ 1.5 kg/sqm blended with the dry sand @ 0.05 cubic meter/ sqm. complete all as specified and directed. |
| 24 | S&F Roof trusses (framed) of angle iron members trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified. |
| 25 | S&F Framed work as in doors or gates of angle or other section of Fe 410 -W (Gde- E- 250) quality-A Fe with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing incl. sliding door bolt complete all as specified. |
| 26 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165complete all as specified and directed. |
| 27 | S&F Framed work such as grills, gratings, or in Flat iron etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165,hung as gates, including pintle hinges, stops, hand made sliding bolts, etc complete all as specified and directed. |
| 28 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde E- 250) quality A complete all as specified and directed. |
| 29 | M&L for preparing of new steel & ironsurfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 30 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measurescomplete all as specified and directed |
| 31 | M&L forpre-paintedhot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specifiedany heightMtr height including all necessary scaffolding and safety measurescomplete all as specified and directed |
| 32 | S&F 2mm thickfibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed |
| 33 | M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete, all as specified and as directed. |
| 34 | M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete, all as specified and as directed. |
| 35 | M&L for Rendering 15mm thick in CM 1:4 with using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces finished fair and even |
| 36 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 37 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finishing fair and even |
| 38 | M&L75 mm thick cement concrete type C2 ,for PCC (1:3:6)using 40 mm graded aggregate used as in sub base, sub floor/pavings and finishing cement concrete surface without using extra cement complete all as specified and as directed. |
| 39 | Plastick dividing strips, 1.5mm thick and 38mm width, inserted in position, conform to design complete all as specified and directed. |
| 40 | M&L for PCC (1:2:4)40 mm thick Type B1 using 20 mm graded aggregate used as infloor/pavings and finishing cement concrete surface even and smooth with using extra cement complete all as specified and as directed. |
| 41 | S&F 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and incl 10mm thick rendering in CM 1:4 complete. |
| 42 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fairlaid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand complete all as specified |
| 43 | M&L steel ventilators with top hung shutter inc. hinges ,steel peg stay complete all as specified. |
| 44 | S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed by Engr-in-Charge.. |
| 45 | All as per item No 44.00 here-in-before but without glazing bar complete all as specified and directed. |
| 46 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 47 | S&F Anodised aluminium snap grid frame work for false ceiling all as specified. |
| 48 | S&F Non asbestos designer fibre cement building boards 4 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 49 | S&F 30 mm thick Flush shutters ,solid core construction ,with block board core and plywood panels ,commercial type on both sides complete all as specified. |
| 50 | S&F 150 mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed. |
| 51 | S&F 100 mm size butt hinges heavy weight cold rolled mild steel hinge fixed with screws complete all as specified and directed. |
| 52 | S&F 150 mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and directed. |
| 53 | S&F 300 mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy and fixed complete all as specified and directed. |
| 54 | M&L forpreparing new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 55 | S&F Sheet glass 4.0 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed. |
| 56 | S&F Stainless steel wire cloth ,0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 57 | M&L for preparation on new plastered surface of brick or concrete surfaces etc and applying two coats of cement basepaint over a coat of primer etc complete all as specified and as directed. |
| 58 | M&L preparing newly plastered surfaces of walls and applying with 03 coats of white wash on walls complete all as specified and directed. |
| 59 | Material & Labour for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces incl preparation of newly plastered surfaces of concrete complete all as specified and directed. |
| 60 | M&L Plain cement concrete type B0, 1:2:4 (using 12.5mm graded stone aggregate) as in benching, bed block, coping of manhole and drain brick wall complete all as specified. |
| 61 | M&L for precast RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in cover slab for manhole, set in cement mortar (1:4) complete all as specified. |
| 62 | M&L for PCC type B-2, 1:2:4 (using 40mm graded stone aggregate) as in floors, channels of drains etc fisnished even and smooth without using extra cement complete all as specified. |
| 63 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extracement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed |
| 64 | M&L for 110 mm dia PVC (SWR) pipes single socketed, in any lengthwith rubber ring joints, laid in trenches or in floorscomplete all as directed. |
| 65 | S&F Reinforced concrete pipes of 600mm dia,class NP2, laid and jointed complete with collars complete as directed. ( The rates include for all necessary extra joints, waste, and cutting etc.) |
| 66 | M&L for concealed point wiring for fan/light point controlled by one one way switchcomplete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dollyincluding sunken in GI terminal box2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect.Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surfaceare deemed to be included in the quoted rate. |
| 67 | All as per item No 66.00 above but using 2.5 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 2.5 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let on same board. |
| 68 | All as per item No 66.00 above but using 2.5 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 2.5 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let on independent board. |
| 69 | Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified |
| 70 | Supply and fixed socket outlet 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch ISI marked complete all as specified |
| 71 | Supply and fixed switch socket combination2 in 1 , 6 pin , (16 Amps ) flush typecontrolled by one switch complete all as specified. |
| 72 | Supply & fixed ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified by EIC. |
| 73 | Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified By EIC. |
| 74 | Supply & fixed lamp holder, polycarbonatebody with back plate straight or angular suitable for batten fittings complete all as specified. |
| 75 | S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. |
| 76 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 77 | Supply & fixing exhaust ventilation fan with louvers of sweep 300mm,230 volts 1200 Rpm, with blade and frame and Outer loures sturdy engineering plastic complete with ,ISI marked complete all as directed by Engr-in-Charge. |
| 78 | S&FLED street lights nominal power 35 Watt,LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumenefficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hoursincluding fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 79 | S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable complete all as specified and as directed |
| 80 | S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 81 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning |
| 82 | Supply and fixed in repairs MCB SPN 32 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating) |
| 83 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI wire 4 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 40 mm diaGI pipe (light grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 32x6mm including protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |
| 84 | Supply, Laying,testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 2 core 10 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,includingBrass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified |
| 85 | M&L Sand Cushioning (dry) in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid ). |
| 86 | M&L for burnt clay fly ash bricks locally availableof size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed. |
| 87 | Supply and fixing GI Light grade 50 mm dia of size for road cross/cutting on wall floor drain etc complete all as specified and directed. |