| 1 | Material and labour in repairs for copper piping size 1/2\" / 1/4\" / 5/8\" as per site requirement with necessary fitting such as elbow bends sockets and tee\"s, clamps and supports on wall and grounds. |
| 2 | Material and labour in repairs for superlone insulationwith necessary fitting for copper pipingsize 1/2\" / 1/4\" / 5/8\"as per site requirement such as elbow bends sockets and tee\"s, clamps and supports on wall and grounds. |
| 3 | Taking down & re-installation of split type air conditioner and fixing of air conditioner all as per directed by Engr-In-charge. |
| 4 | Material and labour for core cutting/drilling/chease cutting of wallup to 18 inch suitable for split type ac as per site requirmentall as per directed by Engr-In-Charge. |
| 5 | Disconnecting split/window type AC (Outdoor+Indoor unit) 1.5/2 TR electrically/mechanically and lowering to the ground fixed in any position for servicing / repairing / overhauling/cleaning, and cleaning filters, checking of electrical wiring, cleaning of dust by blower and washing with washing sodaincluding replacement of unserviceable, burnt out spare parts to make it fully functional, after repair and re-installation and testing on full load completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. NOTE :- Item replaced will be measured and paid separately. |
| 6 | Material and labour for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gasincluding brazing/testing and commissioningcompleteof size 1.5/2 ton capacity all as specified and as directed. NOTE :- The refrigent gas usedwill be paid seperately. |
| 7 | Material and labour for cleaningof gas system of the water cooler/ refrigerator with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas including brazing/testing and commissioningcomplete of capacity 40/80/100/120 ltrs all as specified and as directed. |
| 8 | Material and labour for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/6 HP to 1/2 HP as per site requirement all as specified and as directed. |
| 9 | Material and labour for replacement of unserviceble & damaged burnt blower motor/fan motorof Water cooler of capacity upto 1/8 HP all as specified and as directed. |
| 10 | Material and labour ofgascharging R-22 to splitAcs/Window Acs all as specified and directed. |
| 11 | Material and labour ofgascharging R-32 to splitAcs/Window Acs all as specified and directed. |
| 12 | Material and labour ofgascharging R-134 to water coolet capacity 40/80/100/120 all as specified and directed. |
| 13 | Disconnecting Water cooler of 60/40/80/100/120 Ltr electrically/mechanically for repairing / overhauling / cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, burnt out spare parts such as relays thermostates etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. NOTE :- Item replaced will be measured and paid separately. |
| 14 | Supply and fix in repairs micro processor printed circuit board comlete suitable for splittype AC of 1.5/2 TR as suitable for existing make/model and capacity 1.5/2 Ton complete all as specified and as directed. |
| 15 | Disconnecting and taking out old defective Hermetically sealed compressor unit as required for AC/water coller/refrigerator and Material and labour for fixing new compressor (newsealed unit only)withnut bolt, washer antivibrating bush , brazing work,pressure testing for leakage, vaccuming and gas charging etc of capacity 1.5 TR for window/Split AC of the existing complete all as specified and as directed.MAKE :- Voltas / Hitachi / Emersion / Carrier / Shriram(Techmesh) . |
| 16 | Description all as per item no 15 above but of capacity 2 TR for window/split AC |
| 17 | Description all as per item no 15 above butsuitable for Water cooler of capacity 40ltrs. |
| 18 | Description all as per item no 15 above butsuitable for Water cooler of capacity 60ltrs. |
| 19 | Description all as per item no 15 above but suitable for Water cooler of capacity 80ltrs. |
| 20 | Description all as per item no 15 above but suitable for Water cooler of capacity 100/120/150ltrs. |
| 21 | Supply and fix in replacementthermostate suitable for water cooler/ refrigerator/ AC of any type and any model complete all as specified and as directed. |
| 22 | Material and labour for replacement of overload protection relay for window AC,water cooler and refrigerator ofmake and model as per existing complete all as specified and as directed. |
| 23 | Material and labour for replacement of starting relay for window A/C water cooler & refrigaretor of make and model as per existing complete all as specified and as directed. |
| 24 | Supply and fix in replacement of running/starting capacitor from 10 MFD to 50MFD of 4 pole/6 pole as per site requirment complete all as specified and as directed. |
| 25 | Supply and fix in replacement of running/startingcapacitor from60 MFD to 120 MFD of 4 pole/6 pole as per the site requirement complete all as specified and as directed. |
| 26 | Supply and fix in replacement of PVC float valve for water cooler of size 15mm dia complete all as specified and as directed. |
| 27 | Supply and fix in replacement of drier filtter for AC/water cooler/refrigerator complete all as specified and as directed. |
| 28 | Supply and fix in replacement of capillary tubing of any size not less than 0.5 mtr for AC / Water cooler / refrigerator complete all as specified and as directed. |
| 29 | Supply and fix for PVC drain pipe suitable for water cooler outlet of any capacity complete all as specified and as directed. |
| 30 | Supply and fixin replacement 3 pin plug top of capacity 15 amp complete all as specified and as directed. |
| 31 | Supply and fixof Copper Condenser unit assembly for window AC with all accessories complete of capacity 1.5/2 ton complete all as specified and as directed. |
| 32 | Supply and fix of suction valve for split ACof any capacity complete all as specified and as directed. |
| 33 | Supply and fix in replacment of dischargevalve for split ACof any capacity complete all as specified and as directed. |
| 34 | Supply and fix in replacement ofwater cooler taps as per site requirement complete all as specified and as directed. |
| 35 | Supply and fix for PVC drain pipe suitable for split AC out let of 1.5T/2.Tcapacity complete all as specified and as directed. |
| 36 | Replacement of rubber gasket for lid top of any size for water coolers of any size as per site requirement complete all as specified and as directed. |
| 37 | Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigirators with bushes, sleeves, washers nut and bolt for Compressor foundation legs, relay terminal cover clips and including cutting, brazing, leak detection, charging refrigerent and commissioning testing for 165 - 200ltr capacity complete all as specified and as directed. |
| 38 | Material and labour for dismantling of existingvoltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functionaland rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeofcapacity 2 KVA to 5 KVA upto satisfactory function of any capacity all as directed by Engr- in-Charge. |
| 39 | Supply and fix in replacement of voltage stabiliser upto capacity 5 KVA as per the site and direction of Engr-in-Charge. |
| 40 | Supply and fix in replacement of copper evaporatorunit assembly of indoor unit with all accessories suitable for split AC of 1.5/2.0 Ton capacity all as per site requirement complete all as specified and as directed. |
| 41 | Material and labour for repair only of existing remote control for 1.5/2 Ton split Acs as per the Make/Model at site requirement complete all as specified and as directed. |
| 42 | Supply only new remote control of 1.5/2Tons split Acs as per the make/model at site complete all as specified and as directed. |
| 43 | Disconnecting Electric connection, removing /transporting the unsv water cooler of capacity 40 ltrs to 150 Ltrs to workshop for paintingworkwhich includes removing the existing deteriorated/rusted body for paint by scrapping and filling of cavaties with filler spray, denting/ welding, patch work with existing size of MS sheet and painting the body with synthetic enamel paint two coats over a coat of redoxide and marking the SM/MES No (of reqd size and shape) with black paint complete all as specified for as directed by Engr-in-Charge. |
| 44 | Supply and fixof Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for windos/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge . |
| 45 | Supply and fix in replacment of Copper Condenser unit assembly for Outdoor Unit with all accessories suitable for split ACof capacity 1.5/2 ton complete all as specified and as directed . |
| 46 | Dismantling of old split type air conditioner indoor unit and Supply , installation and testing Indoor unit of split type air conditioner complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton with wall mounted fixing plate suitable size incl breezing work for fixing existing site complete all as directed. MAKE :- Voltas / LG / Blue star |
| 47 | Disconnecting and taking down unserviceable/damage outdoor unit cover of split air conditionerof capacity 1.5 Ton and dismantaling of compressor, condenser unit, wiring, fan motor from outdoor cover and supply and fixing new outdoor cover with replacement of unserviceable spare parts such as capacitor, control wiring and refixing compressor, condenser unit,wiring,fan motor to make it fully functional, after repair and re-installation as per existing and testing on completion to the entire satisfaction of Engr-in-Charge. NOTE :- Items as declared unservicable by Engineer in charge shall be measured and paid separately. |
| 48 | Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 4 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit/Cassing capping of 1.2 mm wall thickness including all fixing accessories, and 4 sqmm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed.NOTE :- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length. |
| 49 | Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 6 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit/Cassing capping of 1.2 mm wall thickness including all fixing accessories, and 6 sqmm PVC insulated stranded copperconductor cable as earth wire connected to earth dolly complete all as specified and directed. NOTE :- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length. |
| 50 | Supply and fixing 3 core2.5 sqmm copper cable for connection between indoor & out door unit 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit/Cassing capping of 1.2 mm wall thickness including all fixing accessoriesall as specified and directed. |
| 51 | Supply and fixing4 core1.5 sqmm copper cable for connection between indoor & out door unit 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit/Cassing capping of 1.2 mm wall thickness including all fixing accessories all as specified and directed. |
| 52 | Supply & fixing of MCB\"s 240V confirming to IS of rating 6A to 32A SP,\" C\" Series, 10 KA breaking capacity complete all as directed by Engr-in-Charge. |
| 53 | Supply and fixing sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earthplug and socket complete with oneMCB SP , 20 Amps, 230 volts complete all as specified and as directed. |