| 1 | Construction of Doglegged Staircase |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 3 | Filling in plinths and floors with hard murum brought |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 oftrap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steelcentering, formwork, laying/pumping, compacting, roughening them if special finishis to be provided, finishing uneven and honeycombed surface and curing etc. complete.The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombedsurface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.),with fully automatic micro processorbased PLC with SCADA enabled reversible Drum Type mixer/concrete Batchmix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grad |
| 5 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailingout water, Steel centering formwork, laying/pumping cover blocks, compaction andcuring roughening the surface if special finish is to be provided (Excluding reinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) |
| 6 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diametersfor R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies,staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detaileddesigns, drawings and schedules. including cutting, bending, hooking the bars, bindingwith wires or tack welding and supporting as required complete |
| 7 | Providing and fabricating structural steel work in rolled sections like joists, channels,angles, tees etc. as per detailed design and drawings or as directed includingcutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat ofanticorrosive paint and over it two coats of oil painting of approved quality and shade etc. |
| 8 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2days and keeping the surface of the base coat rough to receive the sand facedtreatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 9 | Providing and applying two coats of exterior acraylic emulsion paint confirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete. |
| 10 | Providing & Fixingwater level indicator 5 M height |
| 11 | ProvidingDrilling machine for embedding thetor steel bar in concrete column with adhesive paste for min. 100 mm anchorage for cloumn jacketing….etc complete |
| 12 | Providing and applying white-wash in one coat on old / new plastered or masonry surfacesand asbestos cement sheets including scaffolding and preparing the surface by brushingand brooming down etc. complete. |
| 13 | Providing and applying two coats of exterior acraylic emulsion paint confirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete. |
| 14 | Supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. FG-FN/CF. |
| 15 | Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq mm (2+1E) FRLSH grade copper wire……. etc complete |
| 16 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawingwithout hot dip zinc coating including fabricating glazing with plain / obscured glasspanes 5 mm thick and approved type and quality and iron oxidized fixtures and fasteningoil paint 2 coats etc. complete |
| 17 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T orE section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner ofminimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fittedwith snap headed rivets of minimum size 6 mm max. spacing of vertical channels be100 mm enclosed gate position and clear space of 150 mm between two sets ofcrossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coatof red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 18 | Providing and fixing H.D.P container one piece moulded water tank made out of highdensity polythyler and built corrugated inclusive of delivery up to destination hoisting andfixing of accessories such as inlet,outlet overflow pipe inclusive of all tankscapacity between 200 to 1000 liters |
| 19 | Providing,laying & Fixixng PVC pipe of 75 mm dia with fitting etc |
| 20 | Providing and fixing C.P. Angular stop clock with wall flange of approved makecontinental including necessary sockets/union nut etc. complete. |
| 21 | Providing and applying two coats of lead/zinc base oil paint/ bituminous paint ofapproved colour and shade to new wood work and fiber boards including preparing the surface, knotting, scaffolding if necessary, excluding primer coat etc. complete. |
| 22 | Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mmdia G.I. pipe ( Rezan/ concentiDeleted ire 0.75 mm dia ) with hot dip and G.I. coatedhooks as per drawing supported on M.S. angle 50 x 50 x 6 mm at 2.5 mtr. c/cincluding fixing and fastening with wire, painting M.S. angles with one coat of red leadprimer and two coat of oil paint etc. complete.As directed by Engineer in charge.One Running Metre917 1761296 Iron Work 40.06 BDW Providing and fixing 40mm diameter and 1.5 |
| 23 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fastincluding welding link with angle frame at 30 cm c/c with nuts and bolts and horizontalM.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mmand 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side atevery corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mmincluding 3 coats of oil painting etc. complete. |
| 24 | Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing withallfixturesandfittingsintwoleaveswithstrong holdfastembeddedinc.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. |
| 25 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the peripheryof the area . |
| 26 | Testing & Royalty charges |
| 27 | Basic test of cement: standard consistancy,fineness,sp.gravity soundmness etc |
| 28 | Basic test of aggregate Water absorption, sp gravity,impact valvue |
| 29 | Basic test of aggregatesieve analysis |
| 30 | Basic test of aggregateabrasion value |
| 31 | Basic test of aggregateflakiness index & elongation index |
| 32 | Basic test of aggregatestripping value |
| 33 | Basic test of aggregatesoundness |
| 34 | Basic test of aggregate fineness modulus |
| 35 | compressive strength of concrete |
| 36 | concrete mix desgin |
| 37 | steel bar testing |