Tender For Annual Plan-S0111/25 Vellangallur Bp,Vellangallur Gp-Electrification Of Vayajana Park-Vellangallur Gp-Electrification Of Vayajana Park-General Electrical Work
Tender Value
81350
Estimated cost
Bid Submission
20 Feb 2025
0 days left
EMD
2034
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vellangallur → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Annual Plan-S0111/25 Vellangallur BP,Vellangallur GP-Electrification of Vayajana Park-Vellangallur GP-Electrification of Vayajana Park-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | OD121686/2024-2025:Supply of18 W LED Post top light fittting Havells make Ruby mini / Luker ZEUS K lite/bajaj/equivlent make )suitable for 230V/240V single phase AC supply. |
| 3 | 90.3.16:Conveyance, installation, testing and commissioning of all types of T-5 out door light fittings with 4 Nos lamps, sodium vapour lamp fittings, MH lamp fittings, CDMT lamp fittings etc., complete with all accessories in the existing GI pipe and giving connections as required. |
| 4 | OD121688/2024-2025:Supply and providing junction box -Sintex make GS JB 1414/equivlent on surface/recess including providing 32 A4 way strip connector and making good the damages ,colour washing etc as required . |
| 5 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 6 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 7 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 8 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 9 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 10 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 11 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 12 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 13 | 1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm |
| 14 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 15 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 16 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | 90.3.17.3:Supply, conveyance and erection ofthe following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe |
| 18 | OD121735/2024-2025:Supply and Providing 1.5 mtr length 'B' class 40 mm GI pipe in the existing earth pitfor pipe earathing. |
| 19 | 14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. |
| 20 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 21 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 22 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 23 | OD121689/2024-2025:Steel reinforcment work fo RCC work including straightening,cuttung bending and placing in position with binding etc as required. |
| 24 | OD121690/2024-2025: Supply and provding test joint for earthing system using 2 nos of the following strips including cutting and bending to shape ,drilling necessary holes and fixing to the watering pipe etc as required .2x25x6 mm GI strip |
| 25 | OD121691/2024-2025:Supply and Providing Gully trap with cover box of cast iron on the existing masonery work of earth pit including providing Charcoal before the masonery work mixed with soilaround the existing 40 mm GI pipe as earth conductor etc as required. |
| 26 | 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) |
| 27 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 28 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 29 | 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) |
| 30 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 31 | OD121692/2024-2025:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 25x6mm brass nut and bolt . |
| 32 | OD121693/2024-2025:Supply and providing thefollowingsizesof bolt and nut with washers onthe existingM.S box/ earth bus etc. as requiredincluding drillingnecessary holes as required. 12x3mm brass nut and bolt . |
| 33 | OD121694/2024-2025:Supply and fixing the following accessories in the existing board and giving connections etc.32A 2 way Neutral link mounted on DMC/ SMC base |
| 34 | OD121695/2024-2025:Supply and fixing the following accessories in the existing board and giving connections etc.32A HRC Fuse Base with HRC Fuse link |
| 35 | OD121696/2024-2025:Supply and installation ofdust and vermin proofwall mounting SMC Meter boxsuitable for fixing KSEB Meter, cut out Neutral link etc, hinged door construction for the front side , providing vision panel, for the meter compartment, knock out for cable entry and exit. GS-MB 4537 (inside 450x370x200mm) Sintex or its equivalent. |
| 36 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 37 | 90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 38 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 39 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 40 | OD121700/2024-2025: Supplying and providing copper earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with eachsize of glands for the following sizes of cables as required.4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip |
| 41 | OD121702/2024-2025:Supply and providing MS eye bolt hook in wall/parapet for binding support for KSEBservice wire connection |
| 42 | 90.3.17.1:Supply, conveyance and erection ofthe following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe |
| 43 | OD121703/2024-2025:Preparing completion and test certificates for KSEB connection |
AI Tender Summary
Tender Timeline
Feb 13, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 20, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 24, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender