| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead :Of area of 3 sqm. and below |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 5 kmlead.For thickness of tiles 10 mm to 25 mm |
| 3 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:4:8 or leaner mix (i/c equivalent design mix) |
| 4 | Dismantling aluminum / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. |
| 5 | Providing and laying in position Cement concreteof specified grade excluding the cost of centering and shuttering – all work upto plinth level.1:5:10(1 cement : 5 coarse sand : 10 graded crushed stone aggregate 40 mm nominal size) |
| 6 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand)Including all leads lift and carriage. |
| 7 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supportedwith M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete. Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm |
| 8 | Providing ,fixing and applying plaster of paris (Pop) false ceiling consisting on walls along with mouldings and design (NSI) |
| 9 | Providing and fixing PVC louvers of the approved brand on the walls including all fittings .Complete Job NSI |
| 10 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 11 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 12 | Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination of approved shade and other side balancing lamination including second class teak wood lipping of 25mm widex12mm thick with necessary screws and black enameled M.S. butt hinges complete as per directions of Engineer- in-charge |
| 13 | Extra for providing and fixing flush doors with decorative veneering instead of non-decorative ISI marked flush door shutters conforming to ISI: 2202 (Part-I) on both sides |
| 14 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type) |
| 15 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete |
| 16 | 200x10 mm |
| 17 | 150x10 mm |
| 18 | Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. |
| 19 | Providing and fixing bright finished brass handles with screws etc. complete |
| 20 | 125 mm |
| 21 | 100 mm |
| 22 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 23 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 25 | Providing & Fixing of lighting points/Fan points/E-fan points, bell points in 1.52 mm PVC insulated copper wire of laid through PVC conduit/channels of size with its fittings of approved make recessed duly tested & commissioning complete. |
| 26 | Providing, fixing of heating point in 4.02 mm pvc copper wire laid through PVC conduit/channels of required size with its fittings of approved make recessed duly tested and commissioning complete. |
| 27 | Providing and fixing of Power point for Ac in 4.0 sq mm PVC insulated copper wire duly recessed in wall incl 4.0 sq mm wirefor earth link point taken upto D.B duly tested and commissioned |
| 28 | Providing and fixing of wiring point for 3-5 pin 6 amp socket point in l .52mm copper wire laid through PVC conduit pipe/channels with its fitting |
| 29 | Providing and fixing of down lighter (Cobb lights) |
| 30 | Providing and fixing of Crystal Chandelier |
| 31 | Providing and fixing of 12 Module Plates |
| 32 | Providing and fixing of 6 module plates |
| 33 | Providing and fixing of AC socket with mini MCB incl 4 module plates |
| 34 | Providing and fixing of 6 amp switch modular |
| 35 | Providing and fixing of 6 Amp modular socket |
| 36 | Providing and fixing of 16 Amp switch modular |
| 37 | Providing and fixing of 16 Amp socket modular |
| 38 | Providing and fixing of 4 way TPN Distribution board double door |
| 39 | Providing and fixing of 63Amp SPN |
| 40 | Providing and fixing of 40 Amp SPN |
| 41 | Providing and fixing of 6-32 Amp \"C\" curve MCB S/P |
| 42 | Providing and fixing of strip lights |
| 43 | Providing and fixing of Rajouri Map along with covered Glass for background NSI |
| 44 | Providing and fixing of Indian National Flag along with stand NSI |
| 45 | Providing and fixing of flower flask of premium quality NSI |
| 46 | Providing and fixing blinds curtain of approved quality NSI |
| 47 | Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete. |
| 48 | Sand for an avg. diatance of 120 km M.T |
| 49 | Aggregate size below 40mmfor an avg distance of 10 km M.T |