Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47709153

Tender For Repair Maintenance Of Security Street Light Various Types Of Earthling Lightening Protection System And Other Misc E/M Works

Issued by Statutory Bodies & Commissions/Committees · jalahalli, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Mar 2025
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jalahalli → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair Maintenance Of Security Street Light Various Types Of Earthling Lightening Protection System And Other Misc E/M Works

BOQ

NAME OF WORK: REPAIR/MAINT OF SECURITY STREET LIGHT, VARIOUS TYPES OF EARTHING, LIGHTENING PROTECTION SYSTEM AND OTHER MISC E/M WORKS AT CQAE (WE) UNDER GE (M) AF JALAHALLI
Sl. No. Item Description
1Attending complaints for non-functional/ unserviceable street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillers etc)by deploying technically qualified and experienced technicians to find out defects and taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tape to insulate the LT joint etc and testing complete all as specified and as directedat CQAE (WE)
2Note : The following items are deemed to be inclusive of quoted rate :-
3The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
4Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day)
5A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.
6Contractor has to arrange own moveable Generatorof suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.No Electricity shall be provided by the Department on this account.
7Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment\"s to remove the breakdown. Fault will be intimated through Telephone/ SMS.
8Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department.
9Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department.
10Material requiredfor the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the lights fittings shall deemed to beincluded in the rate quoted.
11Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
12All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forfull safetyof the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.
13All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
14Attending and repairing complaint for onelightof any type shall be measured and paid as one Job.
15Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
16Contractor has to ensure serviceability of all Street/ Security Lights in above mentionedDOMESTIC & TECHNICAL AREA on Daily basis in any weather condition at their own arrangement.
17In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
18The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
19The decision of the Accepting Officer in this regards shall be final and binding.
20Supply and fixcontactor of capacity 32- 40 A 3 Pole 415 V with 2NO+2NCincluding taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T
21M&L for wiring of unserviciableTimer panel boxand replacement of existing size of copper wire withcopper lugs and other connected items complete all as specified and as directed
22Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 36 wattLED fittings complete all as specified. Make - CG/Phillips/Bajajor equivalent as per site requirement
23Supply and fix as in repair NO/NC of capacitysuitable for 32-40 A contactorincluding taking down of old one complete all as specified and as directed . Make:- Legrand /Indo Asian /L&T
24Supply and fix digital timer switch 24 hrs including taking down of old one complete all as specified and as directed. Make:- Legrand /Indo Asian /L&T
25Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed and directed. Make:- Legrand /Indo Asian /L& T
26Supply only electronic controller with accessories (LED outdoor Driver) ofsuitable capacityof 40 to45 wattLED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
27Supply only electronic controller with accessories (LED outdoor Driver) ofsuitable capacityof 120 to 150 wattLED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
28Supply only electronic controller with accessories (LED outdoor Driver) ofsuitable capacityof 80 to 100 wattLED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
29Supply only electronic controller with accessories (LED outdoor Driver) ofsuitable capacityof 200 wattLED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
30Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent
31Supply and fixingthe surge protection device 5KV voltage compatible with industrial and out door type LED fixturesincluding taking down of old one complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
32Supply only electronic controller with accessories (LED outdoor Driver) ofsuitable capacity of 60 to 75 wattLED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
33Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling old damaged pole complete all as specified and as directed.Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.
34M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed.
35M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed
36Supplying & fixing Polycarbonate Cable Junction box ofsize 155 mm x 210 mm x 92 mm “weather proof”, for outdoor installation (with knockouts for cable entry) pole mountedfront operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system complete all as specified and directed. Make:- Hensal Cat No - KF 1616 or equivalent .
37Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.
38Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 90 watt complete all as specified and directed.Make:Halonix/Philips/CG/Bajaj
39Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 70 watt complete all as specified and directed.Make:Halonix/Philips/CG/Bajaj
40Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all specified and directed. Make: Plaza/Polycab/ Finolex/Havells
41Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex
42Material and labour for Painting of steel tubular pole 9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from groundlevel shall be painted by alternate layer of black and white enameled paint (30 Cms Each). Pole Nos shall be written on pole withblack paint in yellow circle of 150mm dia, complete all as specified and directed.
43Material and labour for applying one coat of cement base paint to RCCpole 9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of aluminium paint. Cement base paint shall be applied on pole above 1.5 metre height from ground level and balance 1.5 mtr from groundlevel will be painted by alternate layer of black and white enameled paint (30 Cms Each)Pole Nos shall be written on pole withblack paint in yellow circle of 150mm dia, complete, all as specified and directed.
44Taking down and errecting steel swagedtubular pole 8.5/9 mtr long,bracket for fixingstreet lightand refixing the sameincluding necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and copingwith 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specifiedand directed.
45Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:-(i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 luxand for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS.(ii)Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity.(iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 typeB1 for grouting of base including taking down unserviceable panel.The scope of work also comprising the following :-The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller\"s preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use,Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponentSupply and fixing eatures :-
46(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells)(b)Supply Resign cast CT\"S - set of 3(c)Gsm based smart street light controller.(d) Lux based sensor to operate external as per light intensity.(e)Line Contactor, AC 3duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells)(f)MCB SP 32 Amps- 03 Nos(make -L & T, BCH, Havells)(g)Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination.(h) GSM/Timer/Bypass Mode switch.(j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible.Make- Tricolite/ Kewintech/HPL
47Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depthinany type of soil for laying of cables etc up to proper level complete all as specified and directed.
48Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specified and directed.
49Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed.
50Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :-(i)Excavated approved soil obtained from excavation under item No 35 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thicknessshall be considered for payment.
51Material and labour for well burnt‘B’ sub class bricks as protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed.
52Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed. Note :-The tenderer shall take into consideration for the following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.(iii) Removing excavated material/rubbish out side MD land(iv)Laying of any type/any bore of pipe in trenches including taking down any description. Pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces.
53Supply only GI pipe light grade for cable protection of size 40mm bore complete with fitting complete all as specified and directed.
54Material and labour in repair for3 ½ core 35 Sqmm XLPEinsulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts etc, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian
55Material and labour in repair for3 ½ core 25 Sqmm XLPEinsulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian
56Supply and fix street light terminal boxes factory made out of 1.6mm thick PVC sheet with hinges and locking arrangement of size 300x200x100mm housing in and including 25x4mm bus bar of suitable length fixed on porcelian insulator with proper size of screw and one No of MCB SP 6 Amps, 240volts, in/out cable gland of suitable sizefixed on street light pole with nut, bolt and washers etc, complete all as specified and directed.
57Supply & fixing of Polycarbonate Cable Junction box ofsize 205 mm x 255 mm x 112 mm “weather proof”, for outdoor installation (with knockouts for cable entry)pole mountedfront operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system complete all as specified and directed. Make: Hensal Cat No - KF 2525 or equivalent .
58Supply and fixing in repair LED flood light100 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
59Supply and fixing LED flood light 120watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj
60Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells
61Material and labour in repair for4 core 16 Sqmm XLPEinsulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian
62Material and labour in repair for4 core 10 Sqmm XLPEinsulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laid in trenches/cable ducts, fixed to wall/pole complete all as specified and directed . Make :- Havells/Polycab/ RPG Asian
63Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes of 80 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.
64Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s old LT panel board andreconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
65(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps, 16 KA-01 No (Incomer).(b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps, 10 KA-03 Nos.(c) MCB TPN, 415 V of capacity 40 Amps, 10 KA-01 No. (d) Multifunction Meter (V.I,PF) with suitable capacity of CT\"s-01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder-01 No.Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
66Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
67The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate.
68(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
69(iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate.
70(iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
71(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
72(vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
73(vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned.
74(viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab.
75(ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
76(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
77(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
78(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
79(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
80(xiv) The electrode shallcarry manufacturer\"s name .
81(xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
82(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
83(xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil.
84(xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
85(xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by Engr -in- charge.
86Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed.Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO.
87S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing.
88Supply and fixing in repair LED flood light 50 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
89Supply and fixing in repair LED flood light 70 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lampProtection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
90Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25 - 35 Sqmm 3.5 core size of LT underground armoured cables etc complete all as specified and directed.Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
91Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB\"s, DB\"s any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&Fsmall pieces of elctrical cable of size upto 10 Sqmm single core and length not exceeding 0.50m, complete all as specified and as directed.Note:Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.Cost of labour for replacement will be deemed to include in the unit quoted rate.
92Note for item No 91 :- (a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be producedto Engr-in-Charge before commencement of work.
93(b) All bldg light complaints including service connection, sub main & internal electric for entire OTM and Md accn at AF Stn Jalahalli West shall be attended
94(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format as directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
95(d)All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor without any extra cost to deptt.
96(j)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
97(k)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor shall be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
98(l) The decision of the Accepting Officer in this regard shall be final and binding.
99Supply only switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
100Supply only switch piano flush type 5 Amps240 volts single pole two way, complete all as specified and directed. Make :Anchor, Havells, L&T, Indoasian
101Supply only switch piano flush type 15 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
102Supply only shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian
103Supply only switch socket combination out let 3 pin 5 Amps, flush type, complete all as specified and directed. Make :Anchor, Havells, L&T, Indoasian
104Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and 15 Amps, complete all as specified and directed Make :Anchor, Havells, L&T, Indoasian
105Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 Amps, flush type, complete all as specified and directed.Make :Anchor, Havells, L&T, Indoasian
106Supply only Ceiling rose 3 phase/PVC/Polycarbinate 6 Amps,250 volts AC(ISI marked), complete all as specified and directed. Make :Anchor, Havells, L&T, Indoasian
107Supply onlysinglepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996, completeall as specified and directed.(Make/Model : Lexic MCB of MDS LegrandCat No :408587 to 408595 / Indoasian/ Havells.
108Supply only metal clad switch socket single pole and neutral enclosure withtwo pin and earth plug and socket complete with one single pole MCB 20A concealed in walls.Legrand/ Havells/ Indoasian
109Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt WW type , 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed .
110Supply only electriconic bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza/ Indoasian
111Supply only 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
112Supply only electronicfan regulator 230 volts, step type socket type, hum free 100/240 watt , complete all as specified and directedMake :Havells / Anchor/ crabtree/ Indoasian
113Supply only plug top 3 pin 15 AmpsAC 230 volts, complete all as specified and directed. Make : Havells/ Cona/ Plaza/ Indoasian
114Supply onlymodular switch1 way 6 Amp.1 module , complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/Indoasian
115Supply onlymodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian
116Supply onlymodular switch1 way 16 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian
117Supply only modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crab tree/ Anchor/ Indoasian
118Supply only electronic LED driver 36/40W suitable for 2\" x 2\" ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed.
119Supply only electronicfan regulator modular type 230 volts, step type socket type, hum free 100/240 watt, complete all as specified and directed.Make :Havells / Anchor/ Crabtree/ Indoasian.
120Supply & fix in repair decorative surfacemountedultra slim square profile round 12 W LED lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of12 Watt and includingcosidering material & labour forfixing ceiling hight upto 15 Mtr, complete all as per site requirementand as directed.
121M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size and description.Note: (a)2 runs of 4 Sqmm cable along with onerun of 4 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza.
122Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02. Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Make : Philips/ Bajaj/ CG/Havells.
123Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 10 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as per Cat Part No - LBLSN-10-CDL of Make : Crompton or equivalent in Halonix/Bajaj/ Philips
124Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plastered surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
125M&Lin repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 Sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealedPVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following points :-Make of Conduit : Avon Plast/ Supreme/ DiplastMake of Wire : Plaza/ Polycab/ HavellsNote: (a) Switches, sockets outlets,Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
126One light point/fan/bell point controlled by one switch.
127All as per item No. 125 here in before but for one 3 pin socket out 5 Ampon the same board
128All as per item No. 125 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
129All as per Sl No125 above but Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper FRLS cable for earth continuity conductor controlled by one 15A switch socket independently.
130M&L in repairs for point wiring complete with 1.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduitwith accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to wallscovered with modular plates with cover etc and 1.5 Sqmm PVC insulated, unsheathed copper conductor multistrandedFRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for following points :-Make of Cable : Plaza/ Polycab/ HavellsMake of Conduit : Supreme/ Diplast/ Avon PlastNote: (a) Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
131One light point/fan/bell point controlled by one switch.
132All as per item No. 130 here in before but for One 3 pin socket out 5 Ampon the same board
133All as per item No. 130 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
134All as per Sl No 130 above but Wiring with 4 Sqmm copper multistranded unsheathed FRLS cable and 4 Sqmm copper FRLS cable for earth continuity conductor controlled by one 15A switch socket independently.
135Supply and Fix switch piano flush type 5 Amps240 volts single pole one way, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
136Supply and Fixsocket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
137Supply and Fix switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
138Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed. Make : Anchor, Havells, L&T, Indoasian
139Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor / Indoasian
140Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directee. Make : Legrand/ Crabtree/ Anchor / Indoasian
141Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor / Indoasian
142Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor / Indoasian
143Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt WW type , 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed .
144M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza.
145S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13,Make : Bajaj / Philips/ CG/ Havells
146Supply and Fixing in repairs of 2 feet surface mounted battern type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white Aluminium extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02. Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Make : Philips/ Bajaj/ CG/Havells.
147Supply & fix in repair decorative surfacemountedultra slim square profile 18 W LED lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of18 Watt and includingcosidering material & labour forfixing ceiling hight upto 15 Mtr, complete all as per site requirementand as directed.
148M&L in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures is the responsible of the contractor.
149M&L in repairfor stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/woodenbeading fixed on wall including necessary fixing arrangement up to height 11 mtrcomplete all as specified and directed.Note : All safety measures shall be taken by the contractor and nothing extra shall be paid on this account.
150Supply and fix in repair of LED street light 36 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:Halonix/Philips/CG/Bajaj
151Supply and fix in repair of LED street light 45 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:Halonix/Philips/CG/Bajaj
152Supply and fix in repair smart integrated solar all in one LED solar street lightfitting 12 V,15 Watts with IP 66 protection, built-in MPPT charge controller,Lithium ion battery,mono crystalline solar panel,PIR motion sensor complete withanodised reflector, toughened heat resistant glass cover,LED 15watts white colour lamp, connector block with all accessories prewired including bracket,welding, drilling,bolts,nuts and any alteration required for fixing the panel with existing pole, complete all as specified and as directed. Make:Philips/CG/Havells/Bajaj
153Supplying, errecting and fixingas in repair GItubular swaged welded pole of over all height 6.0 m long for all in one solar lightcompletewith cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed .Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.
154Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc, complete all as speified & directed.
155Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexsgonal. head screw, complete all as specified and directed.
156Material and labour for Brazing of copper/Aluminium/GI strip for continuity, complete all as specified and as directed.
157Supply and fixingin repair Air termination, single pointed, alluminium rod 12 mm dia and 300mm longfixed to GI Strip / Alluminium strip including nuts,bolts & washersfor earth conductivity to ground complete all as specified and as directed.
158Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s old LT panel board andreconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
159(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 02 Nos (Incomer).(b) On Load Change over front operated of capacity 400 Amp, 4 Pole, 415 V - 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA- 01 No.(d) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(f) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(iv) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
160Note :- An amount of Rs 59,397.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum.

AI Tender Summary

OUR REF NO 47709153
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 05-03-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair Maintenance Of Security Street Light Various Types Of Earthling Lightening Protection System And Other Misc E/M Works
Basic Detail
Tender No 8130/E8
Bidding Type Tender
Location
City jalahalli
State Karnataka
Key Dates
Publish Date 12 Feb 2025
Submission Date 05 Mar 2025
Open Date 12 Mar 2025
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
8687ff94-dfe1-4ec1-94c1-d92fe86e01d7.html
8130GENPAGE.pdf
8130PS.pdf
BOQ_781198.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 12, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 05, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 12, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

8687ff94-dfe1-4ec1-94c1-d92fe86e01d7.html

pdf

8130GENPAGE.pdf

pdf

8130PS.pdf

xls

BOQ_781198.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender