Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-03-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-03-2025 |
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/pointscomplete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and removing the items from site to store for taking credit (Credit for above items should be made as per conditions seperately) and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and as directed. |
| 2 | Taking down main switch / MCB DBs including MCBs etc of any size and removing the items from site to store for taking credit (Credit for above items should be made as per conditions seperately) and making good distrbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and as directed. |
| 3 | Taking down Geysers and disconnecting water & electric connections, removing to store for keeping in safe custody for BER Board complete all as specified and as directed. |
| 4 | Taking down Ceiling fan/Exhaust fan, sealing cable end,dismantling blades and removing fan and blades to store for keeping in safe custody for BER Board complete all as specified and as directed. |
| 5 | Taking down sub main wiring /service cable including earth wire and removing from site to store for taking credit (Credit for above items should be made as per conditions seperately) and making good disturbed surfaces to match with the existing surfaces of walls, floors complete all as specified and as directed. |
| 6 | M & L for point wiring using proper colour coding complete all as specified with 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor two single core cable (Red and Black colour) confirming to IS 694:1990 Part-II with and includingnon metalic rigid PVC Conduit 25mm dia medium grade with all accessories including cutting chases pinning in, for concealed conduit wiring in wall/ceiling/floor/roof etc, making good of disturbed surface not exc 15cm girth, modular sunk pressed steel terminal box not less than 2mm thick, 50mm deep, covered with frame plate with cover for 01 to 16ways suitable for modular fittings including 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor one single core cable (Green colour) confirming to IS 694:1990 Part-II as continuous earth wire connected to common earth dolly all as specified and as directed for the following:- (a) One light/fan/exhaust fan/bell point controlled by one modular switch/bell push. Note :- (i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. |
| 7 | (b) -Ditto- all as per above Sch \"A\" Item No. 6.00 but one 3 pin modular socket outlet 5 Amp on the same board with other switch. |
| 8 | (c) -Ditto- all as per above Sch \"A\" Item No. 6.00 but one 3 pin modular socket outlet 5 Amp independent board. |
| 9 | (d) -Ditto- all as per above Sch \"A\" Item No. 6.00 but one light point controlled by two, 2-way modular switch. |
| 10 | (e) -Ditto- all as per above Sch \"A\" Item No. 6.00 but one 3 pin socket outlet 15 Amp independent board with 2.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor single core cable (Red, Black and green colour) confirming to IS 694:1990 Part-II. |
| 11 | M & L for modular switch, 1 way 6 Amp, 1 module |
| 12 | M & L for modular switch, 2 way 6 Amp, 1 module |
| 13 | M & L for modular switch, 1 way 16 Amp, 1 module |
| 14 | M & L formodular bell switch 6Amp, 1 module |
| 15 | S & F for modular socket 6Amp, 2/3 pin, combined 2 module. |
| 16 | S & F for modular socket6A/16A, 2/3 pin combined 2 module. |
| 17 | M & L for buzzer, ding dong, AC, 230V single pole. |
| 18 | S & F for modular stepped type fan regulator, 120Watts - 2 module. |
| 19 | S & F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body of size. |
| 20 | M & L in replacement of point wiring using proper colour coding complete all as specified with 1.5 sqmm PVC insulated FRLS/FR-LSZH unsheathed 1100 volts multistranded copper conductor two single core cable (Red and Black colour) confirming to IS 694:1990 Part-II with and including non metalic rigid PVC Conduit 25mm dia medium grade with all accessories including cutting chases pinning in, for concealed/surface conduit wiring in wall/ceiling/floor/roof etc, making good of disturbed surface not exc 15cm girth, S&F Metal box/ sunk cast pressed steel terminal box made out ofsheet 1.25 mm thick for mounting of fittings like switches, switch sockets, sockets, regulators etc, 3 mm thick hylum laminated sheet cover including 1.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor one single core cable (Green colour) confirming to IS 694:1990 Part-II as continuous earth wire connected to common earth dolly all as specified and as directed for the following:-(a) One light/fan/exhaust fan/bell point controlled by one piano type switch/bell push. Note :- (i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. |
| 21 | (b) All as per sch \"A\" Item No. 17.00 here in before but one 3 pin piano type socket outlet 5 Amp on the same board with other switch. |
| 22 | (c) All as per sch \"A\" Item No. 17.00 here in before but one 3 pin piano type socket outlet 5 Amp independent board. |
| 23 | (d) All as per sch \"A\" Item No. 17.00 here in before but one light point controlled by two, 2-way piano type switch. |
| 24 | (e) All as per sch \"A\" Item No. 17.00 here in before but one 3 pin piano type socket outlet 15 Amp independent board with 2.5 sqmm PVC insulated FRLS unsheathed 1100 volts multistranded copper conductor single core cable (Red, Black and green colour) confirming to IS 694:1990 Part-II. |
| 25 | M & L in replacement of piano type switch, 1 way 6 Amp. |
| 26 | M & L in replacement of piano type switch, 2 way 16 Amp. |
| 27 | M & L in replacement of piano type bell switch 6Amp. |
| 28 | M & L in replacement of piano type switch, 1 way 16 Amp. |
| 29 | S & F in replacement of piano type socket outlet 6Amp, 2/3 pin, combined. |
| 30 | S & F in replacement of piano type socket outlet 6A/16A, 2/3 pin combined. |
| 31 | S & F forLamp holder (Batten/Angle) PVC/Polycarbonate type with back plate for batten/angle fittings, complete all as specified and directed. |
| 32 | S & Ffor Lamp LED ADORE PLUS 1 x 9 Watts, CDL, 3 Star rating,heat sink white with Polycarbonate diffuser, B-22 base cap, retrofit type, 220/230 volts, complete all as specified and directed. Make : Havells, Order code No. LHLDDBEBBI8R009/Philips/Bajaj. |
| 33 | Supply and fixing for LED lights fitting 1x 20 Watts (T-8), 4 feet long, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings, complete all as specified and as directed. |
| 34 | Supply and fixing for LED light fitting 1 x 10 Watts (T-8), Mirror type with high out put diffuser 2 feet long, 220 Volts, AC decorative type with driver holder and LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings, complete all as specified and as directed. |
| 35 | S & F for LED light fitting 1x9W/1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size with LED Lamp 1 X 9/10watts, complete all as specified and as directed. |
| 36 | Supply and fixing for Decorative wall light fixture made up of Polycarbonate, suitable for 1 x 9 Watts, retrofit LED lamp, B22 base, CITY-2, 220 Volts, AC, complete all as specified and as directed. Make: Havells, Cat part No. CITY-2, Ordering code no.LHDL03160099/ Philips/Bajaj. |
| 37 | S & F in replacement of Round shape 6 watt, 220 volts, AC, Recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 38 | All as per sch \"A\" item No-31.00 here in before but Round shape 12 watts. |
| 39 | S & F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V, AC, Recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 40 | Fixing only old serviceableLEDTube lightfittings 18/20 Watt,complete received from sch \"A\" item No-32.00 aboveincludingcleaning & connecting up with New 3 core flexible copper conductor cable of suitable size. |
| 41 | Fixing only and connecting single/three phase electric meter 25 to 60 Amps, item received from sch \"A\" item No-32.00 above, complete all as specified and as directed. |
| 42 | Supply and fixing in replacement of Post top lantern LED type 20 watt, 230 volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 43 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 10.0 sq. mm x 2 core cable flat or circular complete all as specified and as directed. |
| 44 | All as per sch \"A\" item No-36.00 here in before but size of cable 6.0 sq. mm x 2 core |
| 45 | M & Lin replacement of Rigid non-metallic PVC conduit 25mm dia (ISI Marks) exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for laying telephone & TV cable connections, complete all as specified and as directed. Note: PVC junction boxes (1 to 4 way) suitable for 25mm dia measured and paid seperately under Sch \"A\" item No.43.00. |
| 46 | S & F in replacement of PVC junction boxes (1 to 4 way) suitable for conduits of size 25mm NB complete all as specified and directed. |
| 47 | M & Lin replacement of sub main wiring with two run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 4.0 sqmm (Red and Black colour) and incl drawn through Rigid non-metallic PVC conduit 25mm dia (ISI Marks) including accesssories, one run of single core PVC insulated unsheathed FRLS copper conductor cable 1100 volt grade multistandard of size 4.0 sqmm (green colour) for earth continuity wire and connected of common earth dolly complete all as specified and as directed.Note:- One run of Rigid non-metallic PVC conduit 25mm dia, three run of 4.0 sq mm copper conductor cable is measured as one unit. |
| 48 | All as per sch \"A\" item No-39.00here in before but of size 2 x 6.0 sqmm +1 x 6.0 sqmm. |
| 49 | Supply and fixing in replacement of Wall mounting fans 230 volts. single phase, 50 Hz, 1450 RPM, Oscillating 400 mm sweep suitable for wall mounting, made of metal body, Copper winding including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and as directed. |
| 50 | S& F in replacement of Sheet metal enclosure 20Amp SP (2P+E) with Metal plug and socket DBs suitable for protection of appliances like AC/Geysers etc complete with one MCB single pole 20Amps, 240Volts including connection, testing and making good the disturbed surfaces, complete all as specified and as directed. |
| 51 | M & L in replacement Earth continunity conductor or main earth ing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of 4.00 mm dia GI or steel wire all as specified. |
| 52 | Supply and fixing for LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection, complete all as specified and as directed. |
| 53 | S& F for GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed on wall with flat iron clamps of size 25 x 4mm - 2 Nos with the help of bolts, nuts, washers etc for fixing of security light fitting, complete all as specified and as directed. |
| 54 | Supply and fixing for Ceiling fan 1200mm sweep, complete with blades, down rods and accessories, 230 V, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable for suitable size, complete all as specified and as directed. |
| 55 | Supply and fixing for Heavy duty Exhaust fan 300mm sweep, made of metal body complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, Copper winding including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and as directed. |
| 56 | All as per sch \"A\" item No-46.00here in before but of Heavy duty Exhaust fan 450mm sweep. |
| 57 | Supply and fix for Water heater storage type, electric,capacity 25 litres.BEE 5 star rated, voltage 230V, 50 Hz, Copper tank including connecting up with three core flexible copper conductor cable for suitable size and wall mounting fastener bolt, nuts & washers etc, complete all as specified and as directed. |
| 58 | S & F in replacement of 1 x 9/10 watts LED Bollard cylindrical shapewith opal acrylic diffuser and IP65 Protection, It is easy to install and provides compartable soft lighting complete all as specified and directed. |
| 59 | Dismantling house service brackets, any type amd making good disturbed work, if brackets are not to be refixed at the same place complete all as specified and as directed. |
| 60 | S& Ffor sheet metal enclosures MCB SPN DBs 12 Way, 240 Volts, 50Hz, AC, double door (12) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and as directed. |
| 61 | All as per sch \"A\" item No-50.00here in before but of MCB SPN DBs 8 Way, 240 Volts, 50Hz. |
| 62 | All as per sch \"A\" item No-50.00here in before but of MCB SPN DBs 4 Way, 240 Volts, 50Hz. |
| 63 | S& F for replacement of sheet metal enclosures MCB TPN DBs 6 Way, 415 Volts, 50Hz, AC, double door (18) suitable for flush mounting and surface mounting, conforming to IP 43 - IK 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and as directed. |
| 64 | All as per sch \"A\" item No-51.00here in before but of MCB TPN DBs 4 Way. |
| 65 | S& F for replacement of miniature circuit breaker (MCB), Triple Pole & Neutral 40 to 100 Amp, rating 415V, 10 KA current carrying capacity, \"B\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 66 | S& F for miniature circuit breaker (MCB), Single Pole & Neutral 40 to 63 Amp, rating 240V, 10 KA current carrying capacity, \"C\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 67 | S& F for miniature circuit breaker (MCB), Single Pole 6 to 32 Amp, rating 240V, 10 KA current carrying capacity, \"B\" curve fixing in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed. |
| 68 | Taking down old service connection/UG Cable removing of site complete all as directed. |
| 69 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 25 sqmm x 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed. |
| 70 | All as per sch \"A\" item No-56.00here in before but of size 16 sqmm x 2 core. |
| 71 | All as per sch \"A\" item No-56.00here in before but of size 10 sqmm x 2 core. |
| 72 | All as per sch \"A\" item No-56.00here in before but of size 6 sqmm x 2 core. |
| 73 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. Note : Rates includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 74 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil. |
| 75 | Removing excavated material n exc. 50m ut n.exc 250 distance and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified. |
| 76 | Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :-Only compacted thickness of sand will be measured and paid separately. |
| 77 | S & F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade not less than 0.45 mtr wide for repairing road cut/footpath carried out under respective items. |
| 78 | Removing and Re-laying for machine pressed precast concrete interlocking paver block any shape and size for repairing road cut/footpath carried out under respective items. |
| 79 | Supply, laying un-reinforced precast concrete cable cover class LV type 1flat size 250mm x 150 mmx 40 mm. |
| 80 | Material and labour for Horizontal directional drilling (HDD) is a streeable trenchless method of Laying (installing) underground cables in a shallow arc along a 40mm/50mm bore path by using a surface-launched drilling rig, with minimal impact on the sorrounding area complete all as specified and as directed by Engr-in-charge. |
| 81 | M&L for GI pipe ,light grade 40mm dia for road crossing of cable for cable protection laid in trenches or above ground surface, complete all as specified and directed. |
| 82 | M&Lfor Earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of SSR PT- I testing on completion with & incl. 15 mm bore lightgrade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) type B1 cover slab with one handle made out of 8mm dia round bar, watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & charcoal alternative layers, necessary excavation earth work, including earthing test point all as specified or indicated including testing on completion and as directed. |
| 83 | Supply, Laying, jointing and leakage testing GI Pipe medium grade including all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches and including dismantling and taking down unserviceable / cracked steel tubing with all fittings of the following sizes as complete all as specified and as directed at site of the following sizes :-Note :-Excavation and other earth work will measured and paid separtely for respective items. |
| 84 | 100 mm dia |
| 85 | 80 mm dia |
| 86 | 50 mm dia |
| 87 | 40 mm dia |
| 88 | 25 mm dia |
| 89 | 20 mm dia |
| 90 | 15 mm dia |
| 91 | S&F Gun-metal, globe or Gate Valve with iron wheel head, screwed bothe ends for iron pipe, ISI marked including taking down of unserviceabel existing gate valve complete all as specified and directed of the following sizes:- |
| 92 | 80 mm dia |
| 93 | 50 mm dia |
| 94 | 40 mm dia |
| 95 | 25mm dia |
| 96 | 20mm dia |
| 97 | 15mm dia |
| 98 | Supply and laying of centrifugally cast (Spun) ductile iron pressure pipe with spigot & socket end, class K-9 in any length laid in trenches, conforming to IS-8329/2000 with cement mortar lining with and including rubber gasket jointing conforming to IS-15382/ tyton joint and including dismantling and taking down unserviceable / cracked DI pipe with all fittings complete all as specified and directed for the following sizes:- |
| 99 | 80 mm dia |
| 100 | 100 mm dia |
| 101 | 150 mm dia |
| 102 | Supply and fixing DI fittings for Flanged pipe, DI Bends, connecting pieces,bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed. |
| 103 | M&L for Rubber gasket joint Spigot and socketed pipes and fittings for the following bore complete all as specified |
| 104 | 80 mm dia |
| 105 | 100 mm dia |
| 106 | 150 mm dia |
| 107 | Taking up cast iron water mains (including all fittings),with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed for the following sizes:- |
| 108 | 80 mm dia |
| 109 | 100 mm dia |
| 110 | 150 mm dia |
| 111 | Supply and laying in trenchesof CI Pipe centrifugally cast, spigot & socket ends pipes, Class LA,including all fittings with lead Joints and including dismantling and taking down unserviceable/cracked CI pipe with all fitting burning out joints and recovering lead complete all as specified and directed for the following sizes:- |
| 112 | 150mm dia |
| 113 | 100mm dia |
| 114 | 80 mm dia |
| 115 | M&L for run leadjoint Spigot and socketed pipes and fittings for the following bore complete all as specified |
| 116 | 80 mm dia |
| 117 | 100 mm dia |
| 118 | 150 mm dia |
| 119 | Supply and fixing CI fittings for Socketed pipe, CI Bends, connecting pieces,bell mouth pieces, tapers, tee pieces of one end flanged and other end spigot or socket upto 150 mm bore complete all as specified and directed. |
| 120 | M&L for lead wool joint Spigot and socketed pipes and fittings for the following bore complete all as specified |
| 121 | 80 mm dia |
| 122 | 100 mm dia |
| 123 | 150 mm dia |
| 124 | M&L for boring the holes under roads pavements, hardstanding by treanch less techonology, using ultrasound technique and necessary machine including DI/CI/GI/HDPE/PP-R Pipe of 25 mm to 150 mm bore suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 125 | M & L for construction of brick masonry valve pit of size 90x90x90cm(internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4)both externally andinternally, external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including40 X 40 X 5mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including two coats of anti-corrosive paint over a coat of red oxide zincChrome primer and necessary earth work in soft/loose soil including demolition of old unserviceable existing valve pit & pit cover complete all as specified & directed. |
| 126 | Dismantling and taking outsluice valve any size and ,M&L for repair sluice valve for 80 mm to 200 mm bore , high tensile stainless steel spindle, including nuts, bolts and gas kit ,glands and refixing after repair etc. complete all as specified and directed. |
| 127 | S&F in repair sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unservicable sluice valve including making arrangement for safe working all as specified and directed.for the following sizes:-Make: BIR, KIRLOSKAR ,Kartar or Equivalent as approved by GE. |
| 128 | 150 mm dia |
| 129 | 100 mm dia |
| 130 | 80 mm dia |
| 131 | S&F CI Non Return Sluice Valveflanged ends of class 1.6 PN,including taking down old existing unserviceable Non Return Valve complete all as specified and directed for the following sizes:-Make: BIR, KIRLOSKAR ,Kartar or Equivalent as approved by GE. |
| 132 | 150 mm dia |
| 133 | 100 mm dia |
| 134 | 80 mm dia |
| 135 | Supply and fix Green & Red button operated push type, Star delta Starter fully automatic suitable for 415 V,AC, 3 phase ,50 Hz suibtable for 5 HP Submersible Pump and Motor complete with Over load tripping circuit (Max relay (14-20 Amp), Reverse phasing , unbalancing, Low voltage , high voltage upto motor terminal and starting time delay and should be housed in Dust proof, Moisture proof and powder coated sheet metal fabricated box with locking arrengement includingtaking down of existing starter complete all as specified and directed. |
| 136 | Supply and fix Green & Red button operated push type, Star delta Starter fully automatic suitable for 415 V,AC, 3 phase ,50 Hz suibtable for 12.5/15 HP Submersible Pump and Motor complete with Over load tripping circuit (Max relay (25-60 Amp), Reverse phasing , unbalancing, Low voltage , high voltage upto motor terminal and starting time delay and should be housed in Dust proof, Moisture proof and powder coated sheet metal fabricated box with locking arrengement includingtaking down of existing starter complete all as specified and directed. |
| 137 | M&L for Painting to pipe of pump house rising mains hydrants, sluice valves, pipe, fittings, NRV, discharge head etc after cleaning, scrapping and making the surfaces free from rust of main externally and painting with two coats synthetic enamelled paint in black / blue / red including marking / writing on pipe etc complete as specified and directed. |
| 138 | M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using GI Strip 25 x 4mm as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plateupto external faceof the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia@ 150 mm c/c both ways with 10 mm dia mild steel bars as in liftinghandle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt). |
| 139 | M & L forEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4mmgalvanised iron strip, complete all as specified and as directed. |
| 140 | S& F in replacement submersible pump/motor 12.5/15HP, Electric driven, 415 Volts, TP suitable for 4/6 inch borewell,Output dia- 80/100 mm, Head 70-90Mtr, 2250 LPM, Vertical type, complete all as specified and directed.Make:-CRI / KSB / KIRLOSKAR |
| 141 | All as per above Sch \"A\" item No 21.00 here in before but 5 HP,415 Volts, TP. |
| 142 | S& F in replacement submersible pump/motor 1.0/1.5 HP, Electric driven, 230 Volts, SP suitable for Open well/Semi UG Sump, Output dia- 20/25 mm, Head 70-90Mtr, 120-150 LPM, Horizontal type, complete all as specified and directed.Make:-CRI / KSB / KIRLOSKAR |
| 143 | S& F in replacement submersible pump / motor 02 HP, Electric driven, 230 Volts , SP, suitable for 25/20mm dia output, bore well casing pipe size 100/150 mm, Head 70-90 Mtr, 100-150 LPM, Vetrical type, complete fitting/fixtures with starter panel, complete all as specified and directed. Make:- CRI, KSB and KIRLOSKAR. |
| 144 | Supply fixing testing and commissioning submersible cable flat 6.0 sqmm x 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer for every column pipe of 3 mtr lenght all as specified and directed. |
| 145 | All as per above Sch \"A\" item No 90.00 here in before but 4.0 sqmm x 3 core.. |
| 146 | Excavating in trenches, in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and geting out soil including forming bottom surface to required slope / gradient for laying cables pipes etc.all as specified and directed including removing cable protection PCC covers/bricks & stacking serviceable covers/bricks for reuse and disposal of unserviceable covers within 50 m all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables/pipes and protection covers. |
| 147 | Removal of surplus excavated soil exc. 50m but n.exc 250 mtr distance and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified. |
| 148 | Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified and directed. |
| 149 | M&L PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified. |
| 150 | M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and as directed. |
| 151 | Supply and fixing for LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection, complete all as specified and as directed. |
| 152 | All as per above but here in before of 90 Watt 230 V AC outdoor type |
| 153 | All as per above but here in before of 70 Watt 230 V AC outdoor type |
| 154 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint compelte all as specified and directed. |
| 155 | Repairs/replacement of solar street light by dismantling panel, battery, PVC battery box, PVC wire LED light etc complete all as specified and directed. |
| 156 | Supply and fixing in replacement of PVC Battery box complete all as specified and directed- |
| 157 | Supply and fixing in replacement of solar LED light 12 Watt completeall as specified and directed |
| 158 | Supply and fixing in replacement of solar panel 50 watt completeall as specified and directed. |
| 159 | Supply and fixing in replacement of solar charger controller panel completeall as specified and directed. |
| 160 | Supply and fixing in replacement of Solar Battery 12 volt 40 AH fully completeall as specified and directed. |
| 161 | Supply and fixing in repairs LED out door driver divices suitable for street light45/60/72 Watt, 230V, 50Hz, completeall as specified and directed. |
| 162 | SITC for Automatic Out door Three phase Street light Timer Switch Digital (24 hours clock timing) type, 415 Volts with battery back up fixing on LT over head line/Electric Pole complete making functional all as specified & directed. |
| 163 | M& L for Junction boxes with PVC water tight encloser, ready made type, aluminium bus bar 25x3 mm, 200mm long fixed on post insulators, nut & bolts, MS Camps including 2.5 sqmm cable for street light connection& controlling with one number single pole MCB 6A, 230 Volts complete all as specified and as directed. |
| 164 | M&L for LT steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31 (9mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulatorand electric connection etc, complete all as specified and directed. |
| 165 | Supply and fixing for LED flood light fittings 210 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size & IP 65/66 protection, complete all as specified and as directed. |
| 166 | S& F for GI Bracket made out from GI pipe 25/32mm dia bend to shape as required, 1.2Mtr long fixed on wall with flat iron clamps of size 25 x 4mm - 2 Nos with the help of bolts, nuts, washers etc for fixing of security light fitting, complete all as specified and as directed. |
| 167 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size16 sqmm x 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed. |
| 168 | All as per above but here in before of size 10 sqmm x 4 core. |
| 169 | All as per above but here in before of size 6 sqmm x 2 core. |
| 170 | Cutting/Boringof road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cableincluding returning filling, Including spreadingand providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy