| 1 | Safe loading Carriage including unloading and proper stacking of following materials from central store Barabanki / JE Store to site of work. |
| 2 | STP Pole 11 Mtr |
| 3 | Polymeric 11 KV Pin Insulator |
| 4 | Top Channel |
| 5 | Dropper Channel |
| 6 | Substation Base |
| 7 | MS Earthing Rod |
| 8 | Transformer 250 KVA |
| 9 | 11 KV XLPE Cable AL 3x70 Sq.MM |
| 10 | LT XLPE Cable AL. 1x240 Sq.MM |
| 11 | ACSR Weasal Conductor |
| 12 | Jointing Kit 3x70 Sq.MM O/D |
| 13 | Stay Set Complete |
| 14 | Other Line Material |
| 15 | Dragging of pole from JE Dump Store to site |
| 16 | Erection of Stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, thumble turn buckle andstay insulate etc. |
| 17 | Stringing and sagging of 11 KV line with ACSR Weasal Conductor including nuzzling binding and jumpering (weasal conductor will be provided by the department) |
| 18 | Chemical Pipe Earthing Boring type |
| 19 | Installation of Mounting of Following capacityof Transformer including its connection between 11 KV and LT Line. |
| 20 | Mounting of 250 KVA Tranformer |
| 21 | Erectionof Substation type double pole with STP 11 Mtr. Long including mounting of Top Channal, base angle with clamps with nut & bolt 33/11 KV line. |
| 22 | Erectionof singleSTP 11 Mtr for Stringing and sagging of conductor 1/6 of total length of poles will remain under the ground and planted on stone pad of size 300x300x75 mm. |
| 23 | Earthing of pole with MS Earthing. |
| 24 | Providing of various type materials. All materials shall be supplied by the contractor. |
| 25 | Nut & Bolt |
| 26 | Clamp for Top/ Dropper / X-arm and T-off Channel etc. |
| 27 | GI Pipe 3\"&4\"\" DIA |
| 28 | G I. TPMO Set |
| 29 | LT XLPE Cable AL. 3.5x70 Sq.MM |
| 30 | PVC Insulated armoured Consumer Service AL. Cable 2x4 Sq.MM (As per current market rate) |
| 31 | LT T/F AL. Busbar 5x5 Sq.Ft. (As per current market rate) |
| 32 | Lockable Distribution Box of size 450x400 MM (Type C) (As per Current Market rate) |
| 33 | Outdoor Type LT Distribution bolts with a rupturing capacity of 5 KA at 415 or 415 or H called for individual items. Openable in front & back suitable for 3 phase for wire 50 Hz AC Supply & an ambient temparature of 45 deg. C. The Cubicile should be weather proof, Dust proof, Bermain proof and incloser protection shall be IP- as per IS 2147-1962 and IS-8623 the pannals & switeches boards shall be fabricated out of 40SWG CRCA Sheet Steel & Provided with 16SWG Hinged door including suitable Foundation. MAIN LT PANEL AT SUBSTATION -160 KVA.Incomer - 1 set of 400 Amp. TP MCCB with Spreader & Extended Hadle Metering on Incomer 1 Set of Digital Ammeter with ASS 1 Set of Digital Voltmeter with VSS 1 Set of LED type phase indication light (22.5MM) with control MCBs Outgoing -6 sts of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel) 2 Sets of 100 Amp. TP MCCB with spreader & Extended handle. (As per current market rate) |
| 34 | Fixing of various type materials. All Labour T&P shall be supplied by the contractor. |
| 35 | Nut & Bolt |
| 36 | Clamp for Top/ Dropper / X-arm and T-off Channel etc. |
| 37 | GI Pipe 4\"&6\"\" DIA |
| 38 | G I. TPMO Set |
| 39 | PVC Insulated armoured Consumer Service AL. Cable 2x4 Sq.MM (As per current market rate) |
| 40 | LT T/F AL. Busbar 5x5 Sq.Ft. (As per current market rate) |
| 41 | Lockable Distribution Box of size 450x400 MM (Type C) (As per Current Market rate) |
| 42 | Outdoor Type LT Distribution bolts with a rupturing capacity of 5 KA at 415 or 415 or H called for individual items. Openable in front & back suitable for 3 phase for wire 50 Hz AC Supply & an ambient temparature of 45 deg. C. The Cubicile should be weather proof, Dust proof, Bermain proof and incloser protection shall be IP- as per IS 2147-1962 and IS-8623 the pannals & switeches boards shall be fabricated out of 40SWG CRCA Sheet Steel & Provided with 16SWG Hinged door including suitable Foundation. MAIN LT PANEL AT SUBSTATION -160 KVA.Incomer - 1 set of 400 Amp. TP MCCB with Spreader & Extended Hadle Metering on Incomer 1 Set of Digital Ammeter with ASS 1 Set of Digital Voltmeter with VSS 1 Set of LED type phase indication light (22.5MM) with control MCBs Outgoing -6 sts of 250 amp. TP MCCB with spreader & Extended handle (3No.+1No. Capacitor panel) 2 Sets of 100 Amp. TP MCCB with spreader & Extended handle. (As per current market rate) |
| 43 | Concreating and pilinthing of ST& PCCPole 18x24 CM. |
| 44 | Laying of Underground 11kv XLPE Cable By drill Method/Manually |
| 45 | Laying of 11kv XLPE Cable By Overhead |
| 46 | Laying of Underground LT XLPE Cable AL. 3.5x70Sq.MM By Manually |
| 47 | LT Distribution Panel Plinth |
| 48 | Testing ofXLPE Cable all size. |
| 49 | Hosting of Cable all size. |
| 50 | Grouting of Pole |
| 51 | Fabricate with hole suitable size in steel items, receive from central store lightas top channel/dropper channel sub station base angle etc. |
| 52 | Looping of cable and mounting of pole all size. |
| 53 | Construction of retaining wall, fabrication & erection of Wiremesh fancing of size 5+3 & 2.0 M height around Transformer and with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 35×35×5 mm jointed with nuts and bolts. The panel must be supported with MS Glat of size 50×6 mm. Wirremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost). |
| 54 | Construction of masonry type transformer plinth of size 1.5×1.5×1.5 M with brick, cement, Coarse sand, sand & brick ballast, filling of sand in the hollow space, plastering outer surface in ratio 1:4:6 top of the plinth 4” thickness grouting of 2 nos. MS Channel of size 100×50×200 mm on the top of the plinth for placement of transformer. (All the material will be arranged by the contractor) |
| 55 | Other line work |