| 1 | Reconstruction of Brick work in following Cement Mortar using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9\" x 4-3/8\" x 2-3/4\" for foundation and basement including curing, etc., complete complying with standard specifiction. |
| 2 | For Foundation and Basement |
| 3 | Replastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Renewing the Stainless stell Family Swing Seater Side Support of pipe \"A\" 2\"\" Pipe and Top Pipe 2\"\" Pipe, Chain Thickness - 8mm and Seats couver with teak wood stifnerss etc., complete. Excluding Labour charges and as directed by the departmental officers. |
| 5 | Renewing and refixing the flush door of 35mm thick solid core flush shutter with commercial ply on both sides with over the plywood fixing 4mm thick OST vaneer sheet on both sides and over with melamine polishing with teak wood lipping alround 35 mm thick bilded with liquid phenol formaldehyde with resin and including labour charges for fixing the shutter to the frams and for fixing the shutterto the frams and fixing anodized aluminium furniture fittings such as bolt hinges 125 x 30mm one aldrop 250mm x 150m long each one Alu. powder coated handle one no and door round lock with screws one no of rubber brush 40 x 60mm one no number ofdoor stopper to the shutters materials and labour etc., complete complying with standard specification and as directed by the departmental officers. |
| 6 | Renewing and refixing the damaged aluminium anodized natural colour matt finish fully PLB partition with 63.50 x 38.10 x 1.28mm extruded box section at bottom, vertical and horizontal members.The vertical members are spaced at 80mm centre to centre to horizontal members are spaced at 0.80M, 1.60M and 2.40M height from the floor level.Panels should be covered with 9mm thick both side PLB exterior grade with necessary accessories like rubber beedings, aluminium clips, screws etc.The aluminium surface is to be anodized with matt finish under electrically controlled condition in accordance with ISI 1868 / 1962 specificaitons for an average wall thicknessof not less than 15 microns.The rate is inclusive of cost of materials, conveyance, scaffolding charges if any required etc and necessary dismantling making holes in RCC (or) masonry works with power drill and redoing the same to the original condition after fixing the partition etc complete complying with standard specification and as directed by the departmental officers at site of work. |
| 7 | Renewing and refixing in position aluminium anodised partly top 1/2 galzed and partly bottom 1/2 panelled door and frame made out of box section 101.6x44.45x3.18mm thick at 2.319 kg\m door shutter made out of box section 47.1x44.45x2.5mm at 1.202 kg\m for vertical style and top, lock rail sections of size 50x44.50x2.5mm @ 1.292 Kg/m and bottom 100.4x44.45x2.50mm at 1.974kg\m using clips of size 17.15x17.27x1.5mm at 0.176 kg\m with necessary metal screws, rubber beading, strike plate type handle ofsize 100x30x1.60mm at 0.988 kg\m on both sides, tower bolts, lock pivot arrangements and top 1/2 portion with5.50 mm thick forested glass and bottom 1/2 portion with both side prelaminated board ( MDF ) 12mm thick for panel portion with 1 No. of hydraulic door closers of approved quality using aluminium extruded section body tubler type universal with double speed adjustment with ISI monogram including cost of furniture fitting such as Pivot, hinges, Tower bolt, lock, door stopper and all materials labour power consumption required for fabrication drilling required for fabrication drilling holes in RCC columns floorslabs masonry wall wherever necessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the aluminium sections are to be anodised with matt finish under electrically controlled condition in accordance with IS 1868-1962 for an average anodic flim thickness of 15 microns etc., complete. The materials should be got approved by the Executive Engineer before use on works. The rate shall be inclusive of all materials, labour for fixing transportation loading, unloading, and all other incidential charges. |
| 8 | Double Leaf |
| 9 | Supplying, fabricating and fixing in position anodised aluminium natural colour matt finish sliding window in all floors with sliding arrangements and gutter arrangement so as to drain the water entering and made with extruded aluminium section of the sizes given below with necessary acessories such as rubber beading.best quality runner, lock, handle supplying and fixing 4mm thick plain glass including cost of all materials, labour power consumption required for fabrication, drilling holes in RCC column/ floor slab/masonry wall wherever necessary with power drills to the required extent and made same to original condition after fixing etc.,complete .The aluminium sections are to be anodized with matt finish under electrically controlled condition in accoradance with ISI 1868/1962 specification for an average anodic film thickness of not less than 15 microns All aluminium sections and furniture fittingsshould be got approved by the Engineer-in-charge before use on works. |
| 10 | Three Leaves |
| 11 | Renewing the damaged hydraulic Door closer of various sizes of approved quality using Aluminium Extruded section body tubular type universal hydraulic door closer with double speed adjustment like HARDWYN (make) \"GAZEL\" (or) equivalent (with ISI Monogram) |
| 12 | Repainting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 13 | Sub Total Amount for above all items (excluding GST) |
| 14 | GST 18% for above SubTotal Amount |