| 1 | Rewinding OfSubmersible Pump Labour with Materials 1 H.P. |
| 2 | Rewinding OfSubmersible Pump Labour with Materials 2 H.P. |
| 3 | Rewinding OfSubmersible Pump Labour with Materials 3 H.P. |
| 4 | Rewinding OfSubmersible Pump Labour with Materials 4 H.P. |
| 5 | Rewinding OfSubmersible Pump Labour with Materials 5 H.P. |
| 6 | Rewinding OfSubmersible Pump Labour with Materials 6 H.P. |
| 7 | Rewinding OfSubmersible Pump Labour with Materials 7.5H.P. |
| 8 | Rewinding OfSubmersible Pump Labour with Materials8 H.P. |
| 9 | Rewinding OfSubmersible Pump Labour with Materials 9 H.P. |
| 10 | Rewinding OfSubmersible Pump Labour with Materials 10 H.P. |
| 11 | Replaing Motar Bush Bearing 1 H.P.TO 3 H.P. |
| 12 | Replaing Motar Bush Bearing 3 H.P.TO 5 H.P. |
| 13 | Replaing Motar Bush Bearing 5 H.P.TO 10 H.P. |
| 14 | Replaing Motar Bush Bearing 10 H.P.TO 20 H.P. |
| 15 | Replaing Motar Busher |
| 16 | Replaing Motar Housing ( C.I.) |
| 17 | Motar Conection Pic ( C.I.) |
| 18 | Motar Rotar Shafing ( S.S.) |
| 19 | Motar Connection Cable 3 Core 2.5 mm Flat Feexsible |
| 20 | Motar Cable Clips |
| 21 | Motar Couler( S.S.) |
| 22 | Motor Thrust Bearing( SKF) |
| 23 | Motor Top Bushing ( Brash) |
| 24 | Motor Stainles Steel Stud( S.S.) |
| 25 | Motor Overhauling Labur Charges |
| 26 | V4-New SubmersibleMotor 90 To 120 mt Head (AC & DC ) 1 HP |
| 27 | V4-New Submersible Motor90 To 120 mt Head (AC & DC ) 2 HP |
| 28 | V4-New SubmersibleMotor90 To 120 mt Head (AC & DC ) 3 HP |
| 29 | V4-New SubmersibleMotor90 To 120 mt Head (AC & DC ) 5 HP |
| 30 | V4-New SubmersibleMotor90 To 120 mt Head (AC & DC ) 7.5 HP |
| 31 | V4-New SubmersibleMotor90 To 120 mt Head (AC & DC ) 10 HP |
| 32 | V4-New Solar AC / DC Motor 1 H.P900 WP90 To 120 mt Head |
| 33 | V4-New Solar AC / DC Motor 2 H.P1800 WP90 To 120 mt Head |
| 34 | V4-New Solar AC / DC Motor 3 H.P2700 WP90 To 120 mt Head |
| 35 | V4-New Solar AC / DC Motor 5 H.P4500 WP90 To 120 mt Head |
| 36 | V4-New Solar AC / DC Motor 7.5 H.P6750 WP90 To 120 mt Head |
| 37 | V4-New Solar AC / DC Motor 10 H.P9000 WP90 To 120 mt Head |
| 38 | Pump P.V.C.Fan - 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 39 | Pump Housing (C.I.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 40 | Pump Connection pic (C.I.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 41 | Pump NRV(C.I.& S.S ) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 42 | Pump Shaft-SS - 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 43 | Pump Coupler(S.S.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 44 | Pump Ampiler (C.I.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 45 | Pump Ampiler (S.S.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 46 | Pump Ampilar(C.I.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 47 | Pump Body(C.I.) 1 H.P. To 3 H.P. Solar Submersible Pump with MNRE Approved |
| 48 | Pump Body(S.S.) 1 H.P. To 3 H.P. Solar Submersible Pumpas per MNRE Approved |
| 49 | Pump Stud-with Nat - 1 H.P. To 3 H.P. Solar Submersible Pumpas per MNRE Approved |
| 50 | Pump P.V.C fan - 5 H.P. To 7.5 H.P. Solar Submersible Pump -Partsas per MNRE Approved |
| 51 | Pump Housing (C.I.) - 5 H.P. To 7.5 H.P. Solar Submersible Pump -Parts as per MNRE Approved |
| 52 | Pump Connection pic (C.I.) 5 H.P. To 7.5 H.P. Solar Submersible Pump Parts as per MNRE Approved |
| 53 | Pump NRV(C.I.& S.S ) 5 H.P. To 7.5 H.P. Solar Submersible Pump part as per MNRE Approved |
| 54 | Pump Shaft-SS - 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as perMNRE Approved |
| 55 | Pump Coupler(S.S.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as per MNRE Approved |
| 56 | Pump Ampiler(C.I.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as per MNRE Approved |
| 57 | Pump Ampiler(S.S.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as perMNRE Approved |
| 58 | Pump Ampiler(C.I.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as per MNRE Approved |
| 59 | Pump Body(C.I.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as perMNRE Approved |
| 60 | Pump Body(S.S.) 5 H.P. To 7.5 H.P. Solar Submersible Pump parts as per MNRE Approved |
| 61 | Pump Stud-with Nat - 5 H.P. To 7.5 H.P. Solar Submersible Pumpparts as per MNRE Approved |
| 62 | M.C for Connectar Replaing 1 H.P To 7.5 H.P |
| 63 | Plus,Minus- Connectar ( + / - ) Replaing 1 H.P To 7.5 H.P |
| 64 | DC/M.C.B. Replaing 1 H.P To 7.5 H.P |
| 65 | Connector - Wiring1 H.P To 7.5 H.P |
| 66 | Controller lock and Key1 H.P To 7.5 H.P |
| 67 | Replaing Controller Box clamp For Fixing to wall / Coloup pipe etc. 1 H.P To 7.5 H.P |
| 68 | A.C. To D.C OrD.C.To A.C. Change Over Switeh 1 H.P To 7.5 H.P. |
| 69 | ON/OFF Swetehen ( L & T ) 1 H.P To 7.5 H.P. |
| 70 | Controller Main Dry1 H.P |
| 71 | Controller Main Dry2 H.P |
| 72 | Controller Main Dry3 H.P |
| 73 | Controller Main Dry5 H.P |
| 74 | Controller Main Dry7.5 H.P |
| 75 | Controller Main Dry10 H.P |
| 76 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 1 H.P |
| 77 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 2 H.P |
| 78 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 3 H.P |
| 79 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 5 H.P |
| 80 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 7.5 H.P |
| 81 | Completely New Contrsler Pannel-I.S.I.MarkMNRE Approved Materials 10 H.P |
| 82 | Providing and Fixing and Replaing Solar Pannels 300 WP |
| 83 | Providing and Fixing and Replaing Solar Pannels D.C. Cable Set Of ( Cirkit ) |
| 84 | Providing and Fixing and Replaing Solar Pannels D.C. Connector per No |
| 85 | Providing and Fixing and Replaing Solar Pannels D.C. Wiring |
| 86 | Providing and Fixing and Replaing Earthing an Der |
| 87 | Replacing SubmersibleCable 4 Sq.mm 3-4 Core |
| 88 | Replacing SubmersibleCable 2.5Sq.mm 3-4 Core |
| 89 | Replacing H.D.P.E.Pipe 32 mm dia 10 kg / Cm² |
| 90 | Replacing H.D.P.E.Pipe 40 mm dia 10 kg / Cm² |
| 91 | Replacing H.D.P.E.Pipe 50 mm dia 10 kg / Cm² |
| 92 | Replacing H.D.P.E.Pipe 63 mm dia 10 kg / Cm² |
| 93 | H.D.P.E.Pipe Nipple 32 mm dia ( S.S.) |
| 94 | H.D.P.E.Pipe Nipple 40 mm dia ( S.S.) |
| 95 | H.D.P.E.Pipe Nipple 50 mm dia ( S.S.) |
| 96 | H.D.P.E.Pipe Nipple 65 mm dia ( S.S.) |
| 97 | S.S. Nut/ Bolt |
| 98 | G.I.Elbow - 25 mm dia |
| 99 | G.I.Elbow - 32 mm dia |
| 100 | G.I.Elbow - 40 mm dia |
| 101 | G.I.Elbow - 50 mm dia |
| 102 | G.I. Coupling - 25 mm dia |
| 103 | G.I. Coupling - 32 mm dia |
| 104 | G.I. Coupling - 40 mm dia |
| 105 | G.I. Coupling - 50 mm dia |
| 106 | Borewell Cap C.I. 140 mm dia ( C.I.) |
| 107 | Borewell Cap C.I. 150 mm dia ( C.I.) |
| 108 | NRV 25 mm dia |
| 109 | NRV 32 mm dia |
| 110 | NRV 40 mm dia |
| 111 | Nipple 32 mm dia ( S.S.) |
| 112 | Nipple 40 mm dia ( S.S.) |
| 113 | Nipple 50 mm dia ( S.S.) |
| 114 | G.I.Union - 25 mm dia |
| 115 | G.I.Union - 32 mm dia |
| 116 | G.I.Union - 40 mm dia |
| 117 | G.I.Union - 50 mm dia |
| 118 | G.I. Pipe - 25mm dia |
| 119 | G.I. Pipe - 32mm dia |
| 120 | G.I. Pipe - 40mm dia |
| 121 | G.I. Pipe - 50mm dia |
| 122 | Providing and erecting earthing for Safty Labour with Materials |
| 123 | Checking Control Pannel Wiring and Repring |
| 124 | Replacing Water Level Guard |
| 125 | Providing and earcting Cable to Sub. Pump 2.5 Sq.mm / 4.00 Sq.mm 3 Core/4 Core ISI Mark |
| 126 | Replacing Sandpost Labour with Materials |
| 127 | Providing and Replacing Sluice Valve 40 mm dia |
| 128 | Providing and Replacing Sluice Valve 50 mm dia |
| 129 | Completey Removing Submersible Pump & motor from Borewell with pipe for Repair to sub.pump and Motor etc. |
| 130 | Completey Borewell Flushing |
| 131 | Providing and Constraction of Two Taos Standpost as per MJP Approved Drawing and Deingn. |
| 132 | Providing M.S. Ladder for water Tankas per ISI Mark DSR Speification |
| 133 | Providing and Ereating H.D.P.E. Water Tank as per ISI Mark |
| 134 | Submersible Pump Overhauling etc Labour Bushar Charges |
| 135 | Submersible Motor Overhauling etcLabour Bushar Charges |
| 136 | Replacing Voltmeter |
| 137 | Replacing Ammeter |
| 138 | Replacing Main Switch |
| 139 | Replacing RoterySwitch |
| 140 | Replacing Push Button |
| 141 | Replacing Indilauting Lamp Indicating Lamp |
| 142 | Providing and erecting Chain link Fencing 1; 6 mtr height G.I. Chain link of Size 50 x 50 x 8 SWG Thick and Fixing 75 mm above GL etc.complete. |
| 143 | Providing and Fixing Mild SheetGrilled Gate as per Detailed drawing,including hinges,locking arrangement and painting etc.complete. |
| 144 | Providing Uncoursed Rubble Stone Masonry of trap Stones in C.M.1;6in Superstructure with pointing etc Labour with Materials etc.complete. |
| 145 | Providing and Fixing Name Board 1x 0.70 Mt Size,16 Gauge, M.S.Sheet ,Painting of one Coast Zink Crome,Primer Two Coats White.etc.complete. |
| 146 | Spacial water Chember etc.complete. |
| 147 | Supplying and erecting Submersible Pumpset of 1.125 kw / 2 HP with 230 V,50 c/s AC Supply Suitable for 100 mm dia etc.complete. |
| 148 | Supplying and erecting Submersible Pumpset of 1.125 kw / 1 HP with 415 V, 50 c/s AC Supply Suitable for 100 mm dia etc.complete. |
| 149 | Supplying and erecting D.O.L. Starter 250 V Single Phase 50 Cycies with Overload element with necessary matarialas andLabour Charges |
| 150 | Supplying and erecting D.O.L. Starter 400 V3 Single Phase 50 Cycies with No Volt Coil and Overload element with necessary matarialas andLabour Charges |
| 151 | Supplying and erecting Submersible Pumpset of 1.125 kw / 1.5 HP with 230 V, 50 c/s AC Supply Suitable for 150 mm dia |
| 152 | Supplying,erecting and Terminating XLPE Armoured Cable 3 1/1 core 2.5 Sq.mm Aluminium Conductor with Continuters 5.48 Sq.mmetc.complete. |
| 153 | Supplying and erecting Fully automatic line Voltge Stabilzer,buck and boost type for operation on inputvoltage 160 to 270 V etc.complete. |
| 154 | Supplying,erecting with Gaivanized iron earth plate size 60 x 60 x 0.6 cm Complete with all Materials,testing & Recording the resultsetc.complete. |
| 155 | Supplying and erecting Marine Plywood 18/19 mm thick fixing to wall or on provided panel board with necessary matarialas such etc.complete. |
| 156 | Supplying and erecting Iron,Sheet ,Metal work consisting of CRCA Sheets,Various sections of iron,plates,chequered plates,rod etc.complete. |
| 157 | Making trench in soft for suitable width and depth for laying provided cable upto 25 Sq.mm etc complete.Rate Rs 138 + 10 %etc.complete. |
| 158 | Supplying and erecting bank of All Polypropylene capacitors with the sandard capacities of q,2,3,4,5,7,12,5,20 and 25 KVAR etc.complete. |
| 159 | Providing & erectng epoxy straight through joint outdoor / indoor for LT PVC Armoured cable 2.5 to 16 sq mm cable etc complete |
| 160 | Excavation for foundation in earth including excavated material up to distance of 50 m and lift as below stacking spreading as directed etc.complete. |
| 161 | In Hard Murum with Bolder Item no 3 MJP DSR 2019-20 Sect E Page no 31 & 39 In soft Murun Item no 1 etc complete. |
| 162 | Filling In Plinth & floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm 20 cm etc complete. |