}

Tender For Electrical Repair Package Job For The Vessel Mv Kalighat At Cksru, Kolkata, kolkata-West Bengal

Cochin Shipyard Limited has published Tender For Electrical Repair Package Job For The Vessel Mv Kalighat At Cksru, Kolkata. Submission Date for this Tender is 18-02-2025. Ship repair and Maintenance Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

47667391
Tender For Electrical Repair Package Job For The Vessel Mv Kalighat At Cksru, Kolkata
Open Tender
Indian
West Bengal
Kolkata
18-02-2025

Tender Details

Tender For Electrical Repair Package Job For The Vessel Mv Kalighat At Cksru, Kolkata; 1 In order to facilitate remove/refit of panels/lagging, following jobs to be carried out.Note: **During refit require consumable like screw, cable tie, lugs upto 4 sqmm, nut and bolt upto 6mm etc under vendor scope.** Connection, disconnection and securing to be carried out. 2 Remove and refit of electrical items tube lights fittings ( 2 x40 w). 3 Remove and refit of electrical items tube lights fittings ( 2 x20 w). 4 Remove and refit of electrical switch sockets 5 amps at cabin space. 5 Remove and refit of electrical switch sockets 16 amps at cabin space. 6 Remove and refit of electricaltoggle switch at cabin space. 7 Remove and refit of fire sensor detectors at cabin space. 8 Remove and refit of emergency lights 24 V DC at passenger space. 9 Remove and refit of cabin bed lamps . 10 Remove and refit of fire alarm point. 11 Remove and secure and refit of electrical cables along cable tray at various type (2 &3 core , 4.5 m2). Approx- 500 m 12 Remove and refit of electrical panel board , switch socket , call point sockets , fridge room evaportor -03 Nos, bulb fittings06 Nos along with associated fittings. 13 Helipad deck illuminution lights stbd base plate found corroded and damaged, same to be cropped and renewed. Approx size ( 160x110x6mm).*Material contractor supply 14 Near carpenter store electrical junction box holding bar corroded and thinned down , same to be cropped and renewed. Approx size (610x70x8mm).*Material contractor supply 15 Life boat emergency light and ISPS flood lightpost round pipe corroded,holed andwasted, same to be cropped and renewed. Approx size ( L-1560 x DIA-800mm), top ISPS frame angle (200x60x60x6mm), top ISPS frame (210x220x110x6mm), flood light frame angle (200x60x60x6mm), flood light frame ( 230x210x100x6mm), side bar ( 70x60x6mm), electrical switch MS plate (100x100x6mm), nut & bolt -04 Nos (12mm).*Material contractor supply 16 Boat deck stbd side electrical wire conduit pipe near life boat No-1,3,5 upper portion holed , corroded and thinned down, same to be cropped and renewed. Approx (500x80mm)-02 Nos, (500x60mm)-02 Nos, (500x50mm)-06 Nos, (500x40mm)-02 Nos.*Material contractor supply 17 Extreme forward conduit pipe of talk back sysytem holed corroded and thinned down , same to be cropped and renewed, approx (500x25mm).*Material contractor supply. 18 Side of lamp store electrical switch socket holding plate , corroded and thinned down, same to be cropped and renewed, approx- (120x120x4mm). 19 Port side ships gangway limit switch conduit pipe thinned down , same to be cropped and renewed. Approxsize (500x40mm).*Material contractor supply. 20 Port & stbdside pilot entrance door base chopping bar half bulb pipe corrode and thinned down, same to be cropped and renewed. Approx size (850x70x8mm).*Material contractor supply. 21 Port side near gangway switch box conduit pipe of flood light holed , same to be cropped and renewed. Approx size (800x40mm)-03 Nos. (sch 40 GI pipe -40NB with removal /relaying of cable- 15 Sqmm x5 Mtr only).*Material contractor supply. 22 Port side near ships gangway conduit pipe of limit switch broken, same to be renewed. Approx size -(400x40mm).*Material contractor supply. 23 MF/HF controller equipment key board button are working erratically, same to be rectified.Make-SAILOR,MODEL-HC 4500** All spares ship supply. 24 VHF hand set cable to be renewed, make- SAILOR, MODEL -RT6222.** All spares ship supply. 25 AIS display found faded, same to be rectified, MAKE-EM TRAK, MODEL-A100.** All spares ship supply. 26 GPS display found faded , same to be rectified, MAKE-JRC, MODEL-JLR-7500** All spares ship supply. 27 Echo sounder showing erratic reading , same to be rectified. MAKE- FURUNo, MODEL –FE 700** All spares ship supply. 28 Doppler speed log showing D-Amp error, same to be rectified. MAKE-SPERRY MARINE, MODEL-NAVIKNOT. ** All spares ship supply. 29 MAGNETIC COMPASS, MAKE- C PLATH Compass 2 Yrly adjustment due on 23.08.2024, same to be carried out and certified. 30 Spare magnetic compass, MAKE- C PLATH Compass 2 Yrly adjustment due on 31.12.2024,same to be carried out and certified. 31 Magnetic compass AC & DC supply dimmer switch Non-operational.same to be rectified.** All spares ship supply. 32 Anemometer display to be shifted to forward of bridge console, cable to be extended from place around. ** All spares ship supply. 33 Talk back system Not working in many places, same to be checked and rectified the defects if required installed suitable speakers -02 No.** All spares ship supply. 34 BAROMETERannual Calibration due on 11.05.2025, same to be carried out& certified. 35 Bridge window wiper blades to be renewed -03 Nos and blade frame alignment to be checked and rectified. 36 Aft main mast mast obstruction redlights Non ops and glass broken ,same to be renewed ,supplied and installed made operational as per sample.** Lights and all spares ship supply. 37 RAM light frame located at aft main mast same to be removed and fitted with new light assembly. RAM Light(ship supply). 38 Ships xerox machine Not working , same to be repiared and over hauled. Make- CANoN, Model-Image Runner 2004, toner catridge model- NPG-59 39 Pre- SRT survey to be carried out with DG approved SRT vendor during APS/SRT survey.** Vendor to arrange DG approved SRT agency.** Authorization certificate to be submitted. 40 Few speakers ofPA system are Not working at various place and PA system controller unit and mike ssytemon bridge also malfunctioning , all cabins and accomodation space speakers to be checked, same to be rectified and made operationalbefore APS completeionsurvey . If required suitabe speakers Make- AHUJA HORN TYPE SPEAKERSto be renewed. Approx - 10 Nos, and cabin BOX type speakers to be renewed - Approx- 15 Nos** All Spare ship supply 41 CANVAS cover of the following equipment to be renewed.** Material contractor supply. 42 CANVAS cover for monkey deckport & stbd search lightto be supplied. Approx size (L-1700 mm x Circum-1300mm) 43 Gyro repeater canvas cover to be supplied. Approx size (L-1700 mm x Circum-1600mm) 44 Life boatNo -3,4,5,6 winch motor cover to be supplied. Approx size (L-800 mm x Circum-1700mm) 45 Life boatNo -1& 2 winch motor cover to be supplied. Approx size (L-1100 mm x Circum-2200mm) 46 Life boatembarkation laddercover to be supplied. Approx size (L-2300 mm x Circum-2300mm) 47 Life jacket box in boat deck port side cover to be supplied. Approx size (L-1350 mm x B-1100X H- 1000mm) 48 Accommodationladder gangway (port & stbd) motor cover to be supplied. Approx size (L-500x cicum-1100 mm) 49 Windlass motor cover to be supplied. Approx size (L-1100 x cicum-2000 mm) 50 Windlass operating remote vertical stand cover to be supplied. approx size(L-1200x cicum-1200 mm) 51 Capstanmotor cover to be supplied. approx size (L-1000 x cicum-1800 mm) 52 Capstan operating remote vertical stand cover to be supplied. approx size(L-1200x cicum-1200 mm) 53 Crane motor coverto be supplied. approx size (L-1100 x cicum-2000 mm) 54 Crane motor electrical junctioncoverto be supplied. approx size (1300 x 1000x500mm) 55 Crane control panel coverto be supplied. approx size (1100 x 200x600mm) 56 Magnetic compass coverto be supplied. approx size (2300 x 1500mm) 57 Control system for port main engine to check, any defects to rectify and RPM is Not responding from bridge same to be checked and rectified, satisfactory operation to be shown to ship staff. Type- PNENUMATIC RC SYSTEM. ENGINE AND CLUTCH.** All spares owner supply 58 Control system for Stbd main engine to check, any defects to rectify, satisfactory operation to be shown to be ship staff.TYPE-PNENUMATIC RC SYSTEM.ENGINE AND CLUTCH.** All spares owner supply 59 EMERGENCY GENERATOR: 60 Control panels to be checked, if any deficiency found same to be rectified with ship supply spare. 61 Smoke & flame sensor to be taken out from the position and cleaned & refitted----5Nos.(each). 62 Pipe line soleNoid valves near p/p discharge side to be overhaul. 24V DC and tank low level alarm to be checked. 63 OWS 15 ppm monitor unit memory and date/time Not working. Same to rectify/reset and shown to ship staff.MAKE-RIVERTRACE ENGINEERING,MODEL- 64 MAIN CIRCUIT BREAKERS: 3 phase, 600v, 1000A 65 Air circuit breakers to overhaul, defects to be rectified andbox back and safety trips and satisfactory trial shown to ship staff.**All spares ship supply 66 Preferential trip to check,satisfactory trial to be shown toship staff. 67 Reverse power trip of all 3 generators to check and satisfactory trial to be shown to ship staff. 68 Under voltage and over current trips of all 3 generators to check and satisfactory trial to be shown to ship staff. 69 Both main engines pressure gauges situated in control room dash board like main lube oil before and after filters, gear oil before and after filters, Fuel oil before and afterfilters, Control air pressure and start air pressure gauges to calibrate and issue proper certificate. Defective pressure gauges to renew (ship supply) and satisfactory trial given to ship staff. **All spares ship supply 70 GALLEY EUIPMENTS: 71 OFFICERS GALLEY 4Nos hot plate(size300mmx300mm) and 1No hot plate(size 400mmx400mm). CREW GALLEY 4Nos hot plate(size300mmx300mm) and 1No hot plate(size 400mmx400mm). PASSENGER GALLEY8 Nos hot plates (size 300mmx300mm) and 1No. hot plate (size 460mmx460mm) above hot plate wiring to be checked and defective wiring to renewed & breaker and switches to check defective to renew.and all plate to be leveled and after completion of work satisfactory trial shown to ship staff.**All spares/material ship supply 72 HOSPITAL ALARM SYSTEM: 73 Deck light fitting bases are corroded/wasted. Some of the main and emergency light fittings are missing. New bases to fabricate and fix. Broken/missing light fittings to renew and shown to ship staff. *Material and consumable contractor supply. 74 AE3 pannel contactor areNot secured properly some time is malfunctioning same to be check and to makeproperly secured arrangment and shown to ship staff. 75 Main emergency battery chargers, main engine control room battery charger panel to be cleaned, bolts & nuts tighttening to be check and shown to ship staff. 76 After restoring power from main switch board supply Emergency generator is Not stopping in auto mode as well as manual mode control panel fault to be checked and rectified satisfactory trail to be shown to ship staff. 77 Fridge rooms light fittings and switch to fit and secure properly(total-04 Nos.) and shown to ship staff. *Material and consumable contractor supply. 78 Search light supply connection cable to be renew 10 mtrs (apporoximate) wire (double core) (each) and male and female socket to be renew port and STBD side 02Nos. satisfactory trial shown to ship staff. *Cable and socket contractor supply. 79 New flood light fittings to beinstalled near boat deck fwd (port and stbd side)MMD surveyer recomandation and shown to ship staff. MATERIAL 20mtrs two core wire,200watts LED lights 2Nos, and 2Nos.male and female plugs and with proper rotating bracketts.**All spares ship supply. 80 Separate wiring to be made for split AC port and STBD for bridge. Wire two core 4mm squre 50 meter (approximate). Required panel to be remove and refit by contractor, satisfactory trial to be showned to ship staff.**Consider the following Removal & refitting of below items over head panel (5000 X 3000)mm, pvc beading and channels-25000 mm, AC ducting -0 02 nos,tubelight fittings(2 X20w)- 02 nos,curtain channel-4000mm,VDR voice recorderr -01 no,curtain wooden rack-02 nos**All spares and cable ship supply. 81 MARINEX DIGITAL, Digital telephone exchange malfuntioning same to be checked and rectified andsatisfactory trial to be showned to ship staff.**All spares ship supply. 82 Switch and plugsto be repair/renew in bridge required spare to be supplied by contractor. approx. 10 Nos. each. Satisfactory trial to be shown to ship staff.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail