| 1 | M & L for complete overhauling of the engine of 500 KVA DG set including replacement of following wornout parts with new parts all as per directions of Eingineer-in-Charge. List of spares with qty are listed below :-(a) Bearing Bush S/E KIR - 01 Nos(b) Con Rod Brg Std - 01 Nos(c) Main Bearing - 01 Nos(d) Liner - 06 Nos(e) Ring - 06 Nos(f) Head Gasket - 06 Nos(g) Set Off Joint - 01 Nos(h) Set O Ring - 01 Nos(j) Valve - 06 Nos(k) Guide - 12 Nos(l) Valve Seal - 12 Nos(m) T/W - 01 Nos(n) Oil Seal - 01 Nos(o) Thermostat Valve - 02 Nos(p) V Belt Cogged - 01 Nos(q) Machinery Job Works - 01 Nos(r) Engine Opening Fitting - 01 Nos(s) Radiator Cleaning(t) Cly Head Job Work - 01 NosNote :1. Any other parts required deemed to be included in quoted rates. Contractor is liable for supply and fix the same with quoted rates.2. Engine dismantling, transportation, refixing, testing after complete overhauling upto satisfaction level of Engineer-in-Charge are included in quoted rates.3. Repairs/overhauling are to be performed only through authorised service centre of Kirloskar |
| 2 | M & L for complete overhauling of the engine of200 KVA DG set including replacement of following wornout parts with new parts all as per directions of Eingineer-in-Charge. List of spares with qty are listed below :-(a) Piston - 06 Nos(b) Ring Set - 06 Nos(c) Head Gasket - 06 Nos(d) CR Bearing - 01 Nos(e) Bearing Bush - 01 Set(f) Set of O Ring - 01 Set(g) Air Filter Set - 01 Set(h) Packing Kit - 01 Nos(j) Oil Seal - 02 Nos(k) Guide - 12 Nos(l) Valve Seal - 12 Nos(m) Water Pump Assy with fuel pump - 01 NosNote :1. Any other parts required deemed to be included in quoted rates. Contractor is liable for supply and fix the same with quoted rates.2. Engine dismantling, transportation, refixing, testing after complete overhauling upto satisfaction level of Engineer-in-Charge are included in quoted rates.3. Repairs/overhauling are to be performed only through authorised service centre of Kirloskar |
| 3 | M & L forcomplete overhauling of the engine of 160 KVA DG set including replacement of following wornout parts with new parts all as per directions of Eingineer-in-Charge. List of spares with qty are listed below :-(i) Bearing Bush S/E KIR - 01 Nos (ii) Con Rod Brg Std - 01 Nos(iii) Main Bearing - 01 Nos (iv) Liner - 06 Nos (v) Ring - 06 Nos(vi) Head Gasket - 06 Nos(vii) Set Off Joint - 01 Nos(viii) Set O Ring - 01 Nos(ix) Valve - 06 Nos(x) Guide - 12 Nos(xi) Valve Seal - 12 Nos(xii) T/W - 01 Nos (xiii) Oil Seal - 02 Nos(xiv) Spinon Lube Oil Filter - 02 Nos(xv) Fuel Filter - 01 Nos(xvi) V Belt Cogged - 03 Nos(xvii) Water Pump Assy - 01 Nos(xviii) Thermostat Valve - 02 Nos(xix) Vent Pipe - 01 Nos (xx) Air Filter - 02 Nos(xxi) FIR Recaliberation - 01 Nos(xxii) Engine Overhauling - 01 Nos(xxiii) Machinery Job Work - 01 Nos(xxiv) Engine Opening Fitting - 02 Nos(xxv) Engine testing and clearing - 01 Nos(xxvi) Load Unloading - 04 Nos(xxvii) Radiator Cleaning Charges - 01 Nos (xxviii) Cylinder Head Job Works - 01 Nos Note :1. Any other parts required deemed to be included in quoted rates. Contractor is liable for supply and fix the same with quoted rates.2. Engine dismantling, transportation, refixing, testing after complete overhauling upto satisfaction level of Engineer-in-Charge are included in quoted rates.3. Repairs/overhauling are to be performed only through authorised service centre of Kirloskar |
| 4 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.INCOMING(a) MCCB 4 pole, 415 Volts,250 Amps, 25 KA - 02 No.OUTGOING(b) MCCB4 pole, 415 Volts, 160 Amps,25 KA -04 No.(c)Onload changeover switch 4P, 415V , 250 Amp -02 (d) Digital multifunction meter with in built selector switchincluding CTs - 01 No.(e) Indicator lamp (RYB) (set of three) - 01 Set |
| 5 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.INCOMING(a) MCCB 4 pole, 415 Volts,400 Amps, 25 KA - 02 No.OUTGOING(b)MCCB4 pole, 415 Volts, 400 Amps, 25 KA - 02 No.(c) Onload changeover Switch 4P, 415V 400 Amp-02 Nos (d) Digital multifunction meter with in built selector switch including CTs - 01 No.(e) Indicator lamp (RYB) (set of three) - 01 Set |
| 6 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.INCOMING(a) MCCB 4 pole, 415 Volts,320 Amps, 25 KA - 02 No.OUTGOING(b) MCCB4 pole, 415 Volts, 200 Amps,25 KA -03 No.(c)Onload changeover Switch 4P 320 A -02 Nos (d)Digital multifunction meter with in built selector switch including CTs - 01 No.(e) Indicator lamp (RYB) (set of three) - 01 Set |
| 7 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.INCOMING(a) MCCB 4 pole, 415 Volts,200 Amps, 25 KA - 02 No.OUTGOING(a) MCCB4 pole, 415 Volts, 125 Amps,25 KA -04 No.(b)Onload changeover Switch 4P,415V 200 A - 02 Nos(d)Digital multifunction meter with in built selector switch including CTs - 01 No.(e) Indicator lamp (RYB) (set of three) - 01 Set |
| 8 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.INCOMING(a) MCCB 4 pole, 415 Volts,200 Amps, 25 KA - 02 No.OUTGOING(a) MCCB4 pole, 415 Volts, 160 Amps,25 KA -02 No.(b)Onload changeover Switch 4P,415V 160 Amp - 02(d)Digital multifunction meter with in built selector switch including CTs - 01 No.(e) Indicator lamp (RYB) (set of three) - 01 Set |
| 9 | Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel,PCC, excavation any other B/R workif required are deemed to be included in quoted rates.--------------------------------------------------------------------------------------------------------------------------------------INCOMING(a) MCCB 4 pole, 415 Volts,160 Amps,25 KA - 02 No.OUTGOING(a) MCCB4 pole, 415 Volts, 63 Amps,25 KA - 06 No.(b)Changeover switch 4P, 415v, 160 A -02 Nos(d) Digital Voltmeter 0-500 Vwith selector switch - 01 No.(e) Digital Ammeter 0-600 Amps with CTs and selector switch - 01 No(f) Indicator lamp (RYB) (set of three) - 01 Set |
| 10 | M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 185 Sqmm 3.5 Core Stranded conductor. |
| 11 | M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 240 Sqmm 3.5 Core Stranded conductor. |
| 12 | M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 400 Sqmm 3.5 Core Stranded conductor. |