Tender For Supply Of Wet Transfer Apparatus , Electro Blot Apparatus: Wet Transfer Apparatus:? Electro Blot Apparatus: Wet Transfer Apparatus: Should Transfer Two 10 X 7.5 Cm Gels Simultaneously; Should Have High Field Strength For Rapid 1 Hr Transfers;
Tender Overview
Project Description
Tender For supply of Wet Transfer Apparatus , Electro Blot Apparatus: Wet Transfer Apparatus:? Electro Blot Apparatus: Wet Transfer Apparatus: Should Transfer Two 10 X 7.5 Cm Gels Simultaneously; Should Have High Field Strength For Rapid 1 Hr Transfers; Should Be Able To Run Overnight At Low Voltage; Electrode-Wires Should Be Placed At Least 4 Cm Apart For Strong Electrical Fields And Efficient Protein Transfer Colour-Coded Cassettes And Electrodes For Proper Orientation Of The Gel During Transfer; Must Have Ice Cooling Unit, Completely Contained Within The Apparatus, For Absorbing Heat Generated During Rapid Transfers;Volume Of Buffer Should Not Exceed 450Ml. Powerpack Basic: Output Specifications 250 V, 3.0 A, 300W Output Range (Programmable) 10-300 V, Fully Adjustable In 1 V Increments 4-400 Ma, Fully Adjustable In 1 Ma Increments 75 W, (Maximum) Type Of Output Constant Voltage Or Current, With Automatic Crossover; Output Terminals: 4 Pair Recessed Banana Jacks In Parallel Timer: Up To 99 Hr, 59 Mm Should Have Pause/Resume Function Operating Condition: 0–40°C, 0–95% Humidity In The Absence Of Condensation. The Catalogue Number And Manufacturer’S Name With Detailed Technical Specifications Claimed Must Be Available On The Website. The Url Link Of The Website Describing The Offered Product Must Be Provided. The Financial Comparison Will Not Be Considered Without A 3-Year Warranty For The Whole Equipment (Including The Circuit).
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Feb-2025 | 2025_BCKV_812716_1_C | Date | 18-Feb-2025 |
BOQ
| Sl. No. | Item Description |
| 1 | Electro blot apparatus: Wet Transfer Apparatus:● Electro blot apparatus: Wet Transfer Apparatus: Should transfer two 10 x 7.5 cm gels simultaneously; should have high field strength for rapid 1 hr transfers; should be able to run overnight at low voltage; Electrode-wires should be placed at least 4 cm apart for strong electrical fields and efficient protein transfer Colour-coded cassettes and electrodes for proper orientation of the gel during transfer; Must have Ice cooling unit, completely contained within the apparatus, for absorbing heat generated during rapid transfers;Volume of buffer should not exceed 450ml. Powerpack basic: Output specifications 250 V, 3.0 A, 300W Output range (programmable) 10-300 V, fully adjustable in 1 V increments 4-400 mA, fully adjustable in 1 mA increments 75 W, (maximum) Type of output Constant voltage or current, with automatic crossover; Output terminals: 4 pair recessed banana jacks in parallel Timer: Up to 99 hr, 59 mm should have pause/resume function Operating condition: 0–40°C, 0–95% humidity in the absence of condensation. The catalogue number and manufacturer’s name with detailed technical specifications claimed must be available on the website. The URL link of the website describing the offered product must be provided. The financial comparison will not be considered without a 3-year warranty for the whole equipment (including the circuit). |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender