Rural Development Government Departments Closing in 0 days TDR #47613346

Tender For Major Repair For Brc Wai Tal Wai

Issued by Government Departments · Kolhapur, Maharashtra
Tender Value
9.57 Lakhs
Estimated cost
Bid Submission
20 Feb 2025
0 days left
EMD
9576
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolhapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Major Repair For Brc Wai Tal Wai

BOQ

Name of Work : MAJOR REPAIR FOR BRC WAI,TAL-WAI.
Sl. No. Item Description
1Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete. (For Ground Floor)Item / Page No : 15 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
2Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 19 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
3Providing and fixing false ceilling of plain asbestos cement sheets 4 milimetre thick with teak wood beadings 45 milimetre X 12 milimetre thick frame work of counrtry teak wood battens of size 70 milimetre X 60 milimetre at 1.00 metre center to center including scaffolding, if necessary, all iron work and painting (visible surfaces) to asbestos cement sheet and beading in two coats, excetra complete. (excluding teak wood runner to be paid seperately). (For Ground Floor)Item / Page No : 13 / 234Specification No : Bd.R.16Spec. Page No : 460
4Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor)Item / Page No : 4 / 173Specification No : Bd.C.8Spec. Page No : 278
5Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer\"s product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For First Floor)Item / Page No : 34 / 236Additional Specifications : The work shall be done as per instructions of Engineer in charge.
6Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 3 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
7Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 40 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
8Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 25 / 215Specification No : Bd.M.13Spec. Page No : 386Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
9Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For Ground Floor)Item / Page No : 10 / 246Specification No : Bd.T.36Spec. Page No : 500
10Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor)Item / Page No : 44 / 254Additional Specifications : The work shall be done as per instructions of Engineer in charge.
11Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 2 / 264Specification No : Bd.U.1Spec. Page No : 537
12Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
13Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
141Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 7 / 209Specification No : Bd.L.4Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
15For First FloorItem / Page No : 7 / 209Specification No : As per Item No 14aSpec. Page No : ---Additional Specifications : As per Item No 14a
16Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For Ground Floor)Item / Page No : 23 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
17Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat), excetra complete. (For Ground Floor)Item / Page No : 9 / 223Specification No : Bd.0.6Spec. Page No : 406
18Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other materials as required, excetra complete. (For Ground Floor)Item / Page No : 24 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
19Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness and size / shape, made by table vibratory method using PU mould, laid in required colour and pattern over 50 milimetre thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed excetra), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed excetra) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed, excetra) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed, excetra) and complete as per manufacturer spsecifications and direction of Engineer-in-Charge. 60 milimetre thick cement concrete paver block of M-35 grade concrete with approved colour and design and pattern.Item / Page No : 6 / 309Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.
20Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.Item / Page No : 37 / 157Specification No : Bd.A.11Spec. Page No : 263-264
21Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor)Item / Page No : 54 / 280Additional Specifications : The work shall be done as per instructions of Engineer in charge.
22Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it.2. Above / below percentage quoted by the contractor will not be applicable for this item.Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks1 Test per 50000.00 Number
23Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre1 Test per Source
24Providing and fixing first class white glazed earthenware Orissa type water closet pan 580 milimetre diameter including \"P\" or \"S\" trap, cast iron soil and vent pipe upto the outside face of the wall, 1:5:10 cement concrete bedding 15 milimetre thick, 10 litre poly vinyl chloride flushing cistern with all necessary pipe connection, excetra complete. (For Ground Floor)Item / Page No : 33 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge.
25Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor)Item / Page No : 88 / 283Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
26Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor)Item / Page No : 40 / 270Specification No : Bd.V.8Spec. Page No : 554
27Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete.Item / Page No : 28 / 277Additional Specifications : The work shall be done as per instructions of Engineer in charge.
28Providing, laying and fixing polyvinyl chloride pipe of 15 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 21 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge.

AI Tender Summary

OUR REF NO 47613346
AUTHORITY Government Departments
TENDER VALUE 9.57 Lakhs
LAST DATE 20-02-2025
Authority
Authority Name Rural Development Department
Work Description Tender For Major Repair For Brc Wai Tal Wai
Basic Detail
Tender No edu/samagra/2024 Dt 3.2.2025
Bidding Type Tender
Location
City Kolhapur
State Maharashtra
Key Dates
Publish Date 06 Feb 2025
Submission Date 20 Feb 2025
Open Date 22 Feb 2025
Finance
Tender Value 9.57 Lakhs
Tender Fee 590
EMD 9576
Exemption Not Available
Document List
BTenderFrom.pdf
Tendernotice_1.pdf
b20eba80-9131-42ec-b3c8-6ba06625556a.html
BOQ_1994600.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 06, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 20, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 22, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

BTenderFrom.pdf

pdf

Tendernotice_1.pdf

html

b20eba80-9131-42ec-b3c8-6ba06625556a.html

xls

BOQ_1994600.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender