| 1 | Charges for operation of lifts at Administrative block as per the terms & condition specified. |
| 2 | Labour charges for rectification of general electrical faults in all electrically connected board/equipments/ all electrical acessories, including replacement, cleaning and making of them in good working condition in all academic zone buildings and as per the terms and condition vide annexure. The replacement items should also be returned promptly for accountability. The rectification of defects and replacement of all accessories should be carried by posting Electrician -3 persons , Helper - 4 Persons & 1 Supervisor ( all above for onlyMaintenece)from 9.00AM to 6.00PM from Monday to Saturday- 1 set consists of Supervisor with C licence , Electrician with \"B\" license &Helper. |
| 3 | Supplying of following accessories for replacement in item no.2 as and when required during the AMC period. |
| 4 | 1200mm x 40 W or 36W fluorescent tube |
| 5 | 600 mm x 20W or 18 W fluorescent tube |
| 6 | 36 W CFL |
| 7 | 40W Electronics ballast |
| 8 | 40W starter |
| 9 | 20W starter |
| 10 | 9Wto 18 W PL Lamp (2pin) |
| 11 | 9w to 18 W PL Lamp (4pin) |
| 12 | 9W /18 W electronic ballast. |
| 13 | 4 Watts LED spot lamps complete set including power supply unit. |
| 14 | 5A 3 pin top |
| 15 | 15 A 3 pin top |
| 16 | Ceiling rose |
| 17 | 2.5 mfd fan condensor |
| 18 | 5 A flush type SP switch |
| 19 | 5 A flush type 2 way switch |
| 20 | 15 A flush type SP switch |
| 21 | 5 A 5pin Flush type socket |
| 22 | 15 A 6 pinFlush type socket |
| 23 | Slanting / Pattern / Pendent PVC holder |
| 24 | Wooden round block |
| 25 | 5 A flush type modular bell Push |
| 26 | 150W Electronics modular make (1 module) stepped fan regulator |
| 27 | 150W Electronics modular make ( 2 module) stepped fan reg. |
| 28 | 20A Metal clad socket top( 2 pin & Earth) |
| 29 | 32 amperes TP+N+E tempra plug TOP |
| 30 | 6 A one way modular type switch |
| 31 | 16 A one way modular type switch |
| 32 | 6 A 3/5 pin Modular socket |
| 33 | 16 A /6 A modularsocket |
| 34 | Blanking Modular plate |
| 35 | 14W T5 FTL (HPL-6500K) warm/ cool |
| 36 | 28w T5 FTL (HPL-6500K) warm/ cool |
| 37 | Supplying ofGI or PVC Box with Modular plate for the following items in concealed or surface with wall and necessary in coming and out going connections. |
| 38 | 3 Module |
| 39 | 5 / 6 Module |
| 40 | 8 Module |
| 41 | 10/12 Module Square or Horizontal |
| 42 | 16/18 Module Square or Horizontal |
| 43 | Supplying and fixing of ball and socket on the existing round block |
| 44 | Providing and fixing extra conduit down rod of 20mm dia, 2x 10cm length wiring with 2core 1.5sqmm FRLS PVC insulated copper conductor, single corecable incl. painting etc as reqd. |
| 45 | Supplying and fixing of additional fan down rods for suspension of fans from ceiling if required. |
| 46 | Supplying & fixing of remote call bell/ buzzer on wall with necessary connections. The guarantee of the bell should be one year. |
| 47 | Supplying and fixing of call bell/ buzzer suitable for D.C/ A.C. single phase, 230 volts, complete set as required.The guarantee of the bell should be one year |
| 48 | Supplying and Laying of following size of flexible copper cable in a suitable PVC pipe/ clamp on wall/ tray with necessary clamping materials. |
| 49 | 3C x 2.5 Sqmm |
| 50 | 4C x 2.5 Sqmm |
| 51 | 3c x 4 sqmm |
| 52 | 4 c x 4 sqmm |
| 53 | 5c x 6 sqmm |
| 54 | Shifting of UPS & allied battery bank (up to 30kVA) with necessary connections |
| 55 | Supplying and fixing of fan hookwith single anchor fationer as insisted by Engineer incharge |
| 56 | Supplying and fixing of fan hookwith double anchor fationer as insisted by Engineer incharge |
| 57 | Removingof Lightfittings/fans/DB\"s/MCB/ Encl and wirings including PVC pipe and acessories |
| 58 | Rewinding of 1200 /1400 mm sweep ceiling fans using enameled copper wire of same gauge, varnishing and required accessories like changing of Ball Bearings, Condensor Clamp , enamel painting with same colour and making the fan working condition .The rate should beinclusive of transport andthe warranty of the workmanship should be minimum six months. |
| 59 | Rewinding of 450 mm sweep Exhaust fans using enameled copper wire of same gauge varnishing and required accessories like changing of Ball Bearings, Condensor, Condensor Clamp and making the fan working condition .The rate should beinclusive of transportation andthe warranty of the workmanship should be minimum six months. |
| 60 | Part-B ( Minor Project Works) |
| 61 | Point wiring in PVC conduit, with modular type switch/regulator wiring for light point/ fan point/ exhaust fan point/ call bell point/ 6 amps switched socketwith 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI / PVC box, ceiling rose, round block and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required and instructed by the engineer incharge. Group C |
| 62 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required and instructed by the engineer incharge. Group C |
| 63 | Supplying and fixing of following modular switch/ socket on a modular plate & G I switch box incl connectionsas required |
| 64 | 6 amps. socket controlled by 6 amps. one way switch. |
| 65 | 6/16 amps. socket controlled by 16 amps. one way switch. |
| 66 | 3x 5 Amps socket controlled by one 15 Amps. Switch |
| 67 | 2x 5 Amps socket controlled by one 15 Amps.Switch + 5 amps. socket controlled by one 5 amps. switch |
| 68 | 6/10/13 amps. International socket controlled by 16 amps. one way switch |
| 69 | Supplying and fixing of following sizeMK premium base & lidCMSwith accessories including end caps, flexible internal/external corners flat angles,Flat tee, joint cover wherever necessary with cable divider, required type of modular box etcas per the site requirements |
| 70 | 100mm x 50mm |
| 71 | 50mm x 50 mm |
| 72 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface medium class PVC conduit as required. |
| 73 | 2 runs of 1.5 sq.mm and 1 run of 1.5 sqmm cable. |
| 74 | 2 runs of 2.5 sq.mm and 1 run of 2.5 sqmm cable. |
| 75 | 2 runs of 4.0 sq.mm and 1 run of 4 sq.mm cable. |
| 76 | 2 Runs of 6.0 sq.mm and 1 run of 6sq.mm cable. |
| 77 | 2 Runs of 10.0 sq.mm and 1 run of 6 sq.mm cable. |
| 78 | 2 Runs of 16.0 sq.mm and 1 run of 6 sq.mm cable. |
| 79 | 4 runs of 4.0 sq.mm and 2 runs of 4 sq.mm cable. |
| 80 | 4 runs of 6.0 sq.mm and 2 runs of 6 sq.mm cable. |
| 81 | 4 runs of 10.0 sq.mm and 2 runs of 6 sq.mm cable. |
| 82 | 4 runs of 16.0 sq.mm and 2 runs of 6 sq.mm copper cable. |
| 83 | 4 runs of 25 sq.mm and 2 runs of 6 sq.mm copper cable |
| 84 | Supplying and drawing of following sizes FRLS PVC insulated copper conductor single/ multi strand cablein the existingsurface/ recessed cable management system / casing capping / PVC /steel condiut as required. |
| 85 | 3 runs of 2.5 sq.mm |
| 86 | 3 runs of 4.0 sq.mm |
| 87 | 3 Runs of 6.0 sq.mm |
| 88 | 6 Runs of 4.0 sq.mm |
| 89 | 6 Runs of 6.0 sq.mm |
| 90 | Supplying and fixing following company madesheet steel, MCB distribution board, 240V or415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interonnect,phosphatized and powder painted incl earthing etc as required. ( without MCB/ RCCB/ Isolator). |
| 91 | 2+6 way single phase and neutral. |
| 92 | 2+8 way/10 way single phase and neutral (double door type) |
| 93 | 4 way (4+12)three phase and neutral (double door type) |
| 94 | 8 way (4+24) three phase and neutral (VTPN DD type). |
| 95 | 12 way (4+36) three phase and neutral (VTPN DD type) |
| 96 | Providing and fixing following of rating and breaking capacity MCCB in the existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required. |
| 97 | 16 kA, 100 amperes 3 pole MCCB |
| 98 | 16 kA,125 amperes 3 pole MCCB |
| 99 | 16 kA,150 amperes 3 pole MCCB |
| 100 | 36 kA,125 amperes 4 pole MCCB |
| 101 | 36 kA,200 amperes 4 pole MCCB |
| 102 | Supplying & fixing of following ratings, miniature circuit breaker in the existing MCB/MCCB DB\"s complete with connections, testing and commissioning etc as required. |
| 103 | 6 - 32 Amperes Single pole MCB |
| 104 | 6 to 32 Amperes double pole MCB |
| 105 | 6 to 32 Amperes triple pole MCB |
| 106 | 6 to 32 Amperes Triple Pole and Neutral MCB |
| 107 | 40A double pole MCB |
| 108 | 40A triple pole MCB |
| 109 | 40A four pole MCB |
| 110 | 63A Double pole |
| 111 | 63A triple pole MCB |
| 112 | 63A four pole MCB |
| 113 | 80A four pole MCB |
| 114 | 100A four pole MCB |
| 115 | Supplying & fixing of following MCB/MCCB\"s inclusive ofsuitable company made sheet steel enclosure on wall/ concealed on wall complete with necessary earth connections and end terminationsas required |
| 116 | 6-32A double pole MCB |
| 117 | 6-32A Triple pole MCB |
| 118 | 6-32A four pole MCB |
| 119 | 40A double pole MCB |
| 120 | 40A Triple pole MCB |
| 121 | 40A four pole MCB |
| 122 | 63A double pole MCB |
| 123 | 63A Triple pole MCB |
| 124 | 63A four pole MCB |
| 125 | 63A TPN MCCB |
| 126 | Supplying & fixing of following metal clad/tempra plug and socket in a company made sheet steel enclosure on wall/in flush with wall with necessary connections and earth connections. |
| 127 | 20A 1Φ MC Plug and Socketcontrolled by 20A DP MCB ( Socket and MCB in a separate enclosures) |
| 128 | 32A 3Φ MC Plug & Socket controlled by 32A TPN MCB |
| 129 | 32A 3Φ Tempra Plug & Socket (3P+N+E-FP)controlled by 32A TPN MCB |
| 130 | 63A 3Φ Tempra Plug & Socket controlled by 63A TPN MCB |
| 131 | Supplying, installation, testing and comm of pre wired following type of FTL /CFL fittings complete with all accessories and Tubes/CFL etc on wall/ ceiling /false ceiling including connect with 1.5 sqmm FRLS PVC insulated single core copper conductor wires and earthing etc as required. The LEDfittings will be supplied CDL/WW/NW as instructed by the Engineer in charge |
| 132 | Crompton LDLSRN28-CDL Model1200mm x 28-Watt LED Batten 3000K/ 6500k |
| 133 | Supply |
| 134 | Installation |
| 135 | Crompton Make LDLSRN24-CDL Model 1200 x 24 W LED Battern3000K/ 6500k or equivalent in Philips |
| 136 | Supply |
| 137 | Installation |
| 138 | Crompton Make LDLSRN36-CDL Model 1200 x 36 W LED Battern6500k or equivalent in Philips |
| 139 | Supply |
| 140 | Installation |
| 141 | Crompton MakeModel TRENDZCCP-143-36-CDL-SL-NWHLED Fitting 5700k-6500k or equivalent in Philips |
| 142 | Supply |
| 143 | Installation |
| 144 | Crompton MakeModel VECTOR I to VII LCTLRF (1 to 7)-36-CDLLED Fitting 6500k or equivalent in Philips |
| 145 | Supply |
| 146 | Installation |
| 147 | Crompton Make Model POLARIS NEO-I LCTLRNE-36-FO-CDL600mm x 600mm36W square panel light with 6500Kor equivalent in Philips |
| 148 | Supply |
| 149 | Installation |
| 150 | Crompton MakeModel POLARIS NEO-I 600mm x 600mm 24Wsquare panel light with 6500Kor equivalent in Philips |
| 151 | Supply |
| 152 | Installation |
| 153 | 600mm x10 Wbattern LED fitting complete set Crompton or Philips make |
| 154 | Supply |
| 155 | Installation |
| 156 | 18W LED Surface mounting fitting complete set.Crompton make Model LCDSPLN-R-18CDL Square or Roundor eqivalent in Philips. |
| 157 | Supply |
| 158 | Installation |
| 159 | 15 W LED Recessed mounting fitting complete set.Crompton make Model Quartz LCDEP or LSDEP 15CDL/WWSquare or Roundor eqivalent in Philips. |
| 160 | Supply |
| 161 | Installation |
| 162 | 18 W LED Recessed mounting fitting complete set.Crompton make Model Quartz LCDEP or LSDEP 18CDL/WWSquare or Roundor eqivalent in Philips. |
| 163 | Supply |
| 164 | Installation |
| 165 | Crompton MakeModel with IP66SUPRA NEO-II TIP-311-70-57-SL-CP-NSG with control gear housing and eye bolt or eqivalent in Philips |
| 166 | Supply |
| 167 | Installation |
| 168 | Supplying and Replacing the following spares for the LED light fittings |
| 169 | 15W to 40W/ 36W LED Driver and surge protecion |
| 170 | 900 mm sweep ceiling fan (Orient PSPO) |
| 171 | 1200 mm sweep ceiling fan (BLDC) |
| 172 | Supply |
| 173 | Installation |
| 174 | 1400 mm sweep ceiling fan (Orient- PSPO) |
| 175 | Supplying and installation of following exhaust fans with metal blade and louvers/ shutters in the existing opening and making connections and testing, commissioning etc as required. |
| 176 | 300 mm sweep exhaust fan with metalic blade |
| 177 | Supply |
| 178 | Installation |
| 179 | 450 mm sweep exhaust fan (heavy duty) |
| 180 | Supplying & providing of 400 mm sweep with metal blade pedestal mounting fan including transporting, assembling and put into service. |
| 181 | Earthing with GI earth plate 600x600x6 mmthick including acessoriesand providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7m long etc with charcoal/coke and salt as required. (or) - Chemical earthing copper bonded solid rod 25mm dia earth electrode with ,3 metre length with 50Kg high conductive earthing compound including all acessoriesand providing HDPE round earth pit chamber and cover (300MMx350MM) with cover plate having locking arrangement as instructed by engineer incharge(make: cikit,infinite, Ashlok). |
| 182 | Earthing with copperearth plate 600x600x3mmthick including 2 Runs of 25 x 3 mm copper flat between the bottom of the plate and theclamp fixed on the top of the GI pipe , funnel etcand providing masonary enclosure with cover plate having locking arrangement and watering GI pipe of 2.7m long etc with charcoal/coke/salt and salt as required. |
| 183 | Supplying and laying of following size earth flats/ earth wire in PVC pipe at 0.50 mt below the earth including soldering /welding as required |
| 184 | Single run of 4 sqmm multistranted copper wire in a suitable PVC pipe and clamps |
| 185 | Single run of 6 sqmm multistranted copper wire in a suitable PVC pipe and clamps |
| 186 | Single run of 10 sqmm multistranted copper wire in a suitable PVC pipe and clamps |
| 187 | Single run of 16 sqmm multistranted copper wire in a suitable PVC pipe and clamps |
| 188 | 25 x 5mm copper strip |
| 189 | 25 x 5mm GI strip |
| 190 | Supplying and fixing following company made sheet steel, Race ways and acessorieson floor surface/ recess, complete suitable for detachable junction boxes , interconnections, phosphatized and powder painted including earthing etc as required. |
| 191 | Floor junction box cover |
| 192 | FLOOR junction box |
| 193 | Popup Box 8 Module -MK |
| 194 | Floor Race Ways Aluminium |
| 195 | CABLE TRAY |
| 196 | Supply,Installation, testing and commissioning of powder coated Perforated Cable Tray of2 mm thick with perforation not more than 17.5% with bend TEE extra and suspended from ceiling orgrounting on wall with suitable angle iron supports withGI Angle/Hitech suitable threaded rods with Anchor fasteners, Clamps, bolts,nuts including all the necessary fastener etc.,to suit site conditions as required. |
| 197 | 300mm x 50mm x 1.6mm |
| 198 | 450mm x 50mm x 2mm |
| 199 | 450mm x 62.5mm x 2mm |
| 200 | 600mm x 62.5mm x 2mm |
| 201 | Concrete earth chamber with cover plate inner size 350X350X350 mm including excavation and all masonary works. The work should be inclusive of white washing the masonary pedastals , paint marking for the earth values, date of testing done , due date for the next test and pit numberontheenclosures and also inside theearth pit. |
| 202 | Testing of earth electrodes using necessary testing equipment and improve the earth by excavating the soil and sub soil and refilling the same with alternate layer of charcoal/coke and salt if required. The values are to be entered in a seperate registerandsubmitted to the Engineer incharge . The work should be inclusive of replacement of bolts and nuts, white washing the masonary pedastals , paint marking the earth values, date of testing done , due date for the next test and pit numberontheenclosures and also inside theearth pit. |