| 1 | Dismantling existing barbed wire/plain wire/ chain linkfencing any type from RCC/Steel/Wooden posts complete etc all as specified and as directed. |
| 2 | Dismantling posts or struts(wood ,steel or RCC) of any section including taking out embedded portion of concrete, brick work of any and making good disturbed ground all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 4 | M&L for PCC 1:4:8type D2, using 40mm graded stone aggregate as in foundations, filling and mass concreteall as specified and directed |
| 5 | M&L for PCC 1:3:6type C2, using 40mm graded stone aggregate as in foundations, filling and mass concreteall as specified and directed |
| 6 | M&L providing reinforced cement concrete type B1, 1:2:4 (20mm graded stone aggregate) in precast pillar, post, fencing posts, straining or terminal posts, struts etc., for fencing, average sectional area exc 100 and n.exc 250 Sq cm with or without chamfered angles and flat, splayed rounded or mitred tops as directed and fixed all as specified and directed. Note :- Reinforcement shall be measured and paid separately. |
| 7 | All as per item above here-in-before but sectional area n.exc 100 Sq cm |
| 8 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintel up to 1.5m clear span, cills, steps, bands, copings,bed plates, hold fast blocks including weathering, slightly rounded or chamfered, angle and throating as directed and other similar work including necessary form work complete all as specified and directed |
| 9 | M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in cover slabs or in similar works etc including necessary form work andset in CM 1:6, complete all as specified and as directed. |
| 10 | Demolition ofreinforcement cement concrete (of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 11 | M&L for RCC TypeB1 1:2:4(using 20 mm graded aggregate) as in Beams/bands cantilevers, bressummers, lintels over 1.5m span all complete and as specified and directed. |
| 12 | M&L RCC1:2:4 type B1 (20mm graded aggregate) for foundation including rafts footing ,foundation beams plinth beams bases for columns etc basement slab, under reamed piles and mass concrete all as specified and as directed. |
| 13 | M&L RCC 1:2:4 type B1 (20mm graded aggregate) Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses all as specified and as directed. |
| 14 | M & L Providing Reinforced cement concrete (nominal mix), in type B1, 1:2:4 mix ( using 20 mm graded stone aggregate ) and as in Columns, pillars, piers, posts and struts,complete all as specified and directed. |
| 15 | Formwork to flat rough finished surfaces of concrete sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfair finished surfaces complete all as specified and directed.. |
| 16 | Formwork to faces of walls, retaining walls, abutments,parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 17 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar work, of rough finished surface (Square, rectangular or polygonal) of concrete, complete all as specified and directed. |
| 18 | M& L for form works to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including support , overhangs etc. for rough finished surfaces complete all as specified and directed. |
| 19 | S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed. |
| 20 | S&F mild steel TMT bars 6mm to 8mm mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or securing with clips complete all as specified and directed. |
| 21 | S&F mild steel TMT bar 5mm dia and over upto and including 10mm diaas in stirrups, spacers & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia or securing with clips complete all as specified & directed. |
| 22 | S&F mild steel works inposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling ,bolting or riveting etc and similar works conforming to Fe-290 (Gde-E-165) all as specified and directed |
| 23 | Supply only mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed at other fitted with washer and nut 5 to 10mm dia and 100 to 150mm long complete all as specified and directed. |
| 24 | S&F MS framed work as in doors or Gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and fixing complete conforming to Fe-410-W (Gde-E-250)quality-B complete all as specified and directed. |
| 25 | Material and labour for preparation and applying two coats of synthetic enamel paint over a coat of red oxideprimer on newly treated steel surfaces of any description, etc complete all as specified and as directed. |
| 26 | Supply only chain link mesh of size 50x50x4mm and made of galvanized wire and shall confirm to IS 2712-2003 and having zinc coating of type heavy as laid down in IS 4826 including line wires/binding wire etc fixed to any type of standards posts complete all as specified and as directed |
| 27 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolt, etc including provision of binding wire, complete all as specified and as directed |
| 28 | M&L for mild steel round bars 10 and over dia as required, made to shape for securing chain link fencing etc.,and similar works conforming to Fe-290 Gde E-165 and including preparation and applying two coats of synthetic enamel paint over a coat of red oxideprimer before fixing etc complete all as specified and as directed |
| 29 | M&Lin repair Concertina coil super barb - bladed profile of dia 600 mm and 2.50mm wire dia of weight not less then 8.50 kgs and 6 mtrs length per coil fixed to angle iron brackets or masonry surfaces with necessary accessories like straining wires, fixing clips etc complete all as specified and as directed.Note :- Concertina coil shall be measured linearly of fencing length.The number of spirals shall not be less than 51 in 6 m length of each coil completed all as specified and directed.. |
| 30 | Removing and refixing existing old concertina coil of 600mm dia weighing approx 8.5kg/7.5m or stacking already fallen concertina coil and refixing the same at position including stacking properly, restraining etc complete all as specified and directed |
| 31 | S&F in repairs, Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 32 | Removing and Restraining, resecuring, Refixing of old existing Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings or untangle fallen old barbed wire and straining and refixing to any type of standard rails straining bolts, including making good , securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 33 | Demolition of brick work or stone/boulders, PCC block masonry built in Cement Mortar or cement lime mortar including all quoins, arches, pillars etc excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed. |
| 34 | Demolition of cement concrete (unreinforced) of any description and in any position and disposed off to a distance exc. 50 mtrs and not exc. 250 mtrs all as directed by Engr-in-Charge. |
| 35 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as directed. |
| 36 | M&L providing precast cement concrete jallies, 25mm thick type B0 1:2:4 (12.5mm graded aggregate) and set in CM 1:6, (measured solid), including all mouldings all as specified. |
| 37 | M & L for Pre-cast cement concrete block masonry with solid blocks, Type C11:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 38 | M&L for brickwork with sub class \"B\" old size bricks, straight or curved on plan, exceeding 6M mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 39 | M&L for half brickwork with sub class \"B\" old size bricks, straight or curved on plan, to any radius built in cement mortar 1:4 complete all as specified and as directed. |
| 40 | M&L MS framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ;ladders; railings;similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed. |
| 41 | M&L for plastering inexternal wall surfaces of 15mm thick in CM 1:4on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed by Engr -in- charge. |
| 42 | M&L for plastering inexternal stone wall surfaces of 15mm thick in CM 1:4on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed by Engr -in- charge. |
| 43 | M&L for preparation of newly plastered surfaces of external walls and applying two coats cement base paint over a coat ofcement primer complete all as specified and directed by the Engineer-in-Charge. |